Sitthisak Audomsi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sitthisak Audomsi has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Worawat Sa-Ngiamvibool
Electrical and Computer Engineering Research Unit, Faculty of Engineering, Mahasarakham University, Maha Sarakham 44150, Thailand
15 shared publications - Jagraphon Obma
Rajamangala University of Technology ISAN, Khonkaen Campus
6 shared publications - Kittipong Ardhan
Kalasin University
4 shared publications - Chatmongkol Areeyat
Faculty of Engineering, Mahasarakham University, Maha Sarakham, Thailand
3 shared publications - Chonlatee Photong
Mahasarakham University
3 shared publications - Natpapha Chansom
Rajamangala University of Technology ISAN, Khonkaen Campus
2 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7143
Enhanced Speed Control of PMSM Using Sliding Mode Controller Optimized by Chess Optimization Algorithm
This paper introduces an enhanced speed control strategy for permanent magnet synchronous motors (PMSMs) through the application of sliding mode control (SMC) optimized by the Chess Optimization Algorithm (COA). Additionally, the proposed method is compared with other validated algorithms, such as Harris Hawk Optimization (HHO) and the Whale Optimization Algorithm (WOA). The SMC parameters are optimized using Integral of Time-weighted Absolute Error (ITAE) and Integral of Time-weighted Square Error (ITSE) as objectives function, and the controllers are validated in MATLAB/Simulink analyzing transient response, speed variation, and load disturbance conditions. The results show that COA-tuned SMC provides better performance, with the lowest overshoot of 0.1929% for ITAE and 3.4800% for ITSE, the fastest settling times of 0.00307 s for ITSE, and the lowest MAE and RMSE in most evaluated scenarios, offering the most balanced overall performance among the optimization algorithms tested. Comparison to PI and PID controllers demonstrates that SMC provides enhanced accuracy, robustness, and disturbance rejection. COA-SMC provides an efficient and stable solution for PMSM applications that demand quick and accurate speed regulation.
- 16 July 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (14) , 7143
Open AccessEnhanced Speed Control of PMSM Using Sliding Mode Controller Optimized by Chess Optimization Algorithm
This paper introduces an enhanced speed control strategy for permanent magnet synchronous motors (PMSMs) through the application of sliding mode control (SMC) optimized by the Chess Optimization Algorithm (COA). Additionally, the proposed method is compared with other validated algorithms, such as Harris Hawk Optimization (HHO) and the Whale Optimization Algorithm (WOA). The SMC parameters are optimized using Integral of Time-weighted Absolute Error (ITAE) and Integral of Time-weighted Square Error (ITSE) as objectives function, and the controllers are validated in MATLAB/Simulink analyzing transient response, speed variation, and load disturbance conditions. The results show that COA-tuned SMC provides better performance, with the lowest overshoot of 0.1929% for ITAE and 3.4800% for ITSE, the fastest settling times of 0.00307 s for ITSE, and the lowest MAE and RMSE in most evaluated scenarios, offering the most balanced overall performance among the optimization algorithms tested. Comparison to PI and PID controllers demonstrates that SMC provides enhanced accuracy, robustness, and disturbance rejection. COA-SMC provides an efficient and stable solution for PMSM applications that demand quick and accurate speed regulation.
- Open Access
- 6 June 2026
- Published by Elsevier in Results in Control and Optimization
- Vol. 23
Enhanced Ant Lion Optimizer for cascade (1+PI)-PIDF control in hydro-thermal power systems with capacitive storage
- 6 June 2026
- Published by Elsevier in Results in Control and Optimization
- Vol. 23
Open AccessEnhanced Ant Lion Optimizer for cascade (1+PI)-PIDF control in hydro-thermal power systems with capacitive storage
- Open Access
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 25590-25603
Chess-Optimized Fuzzy-2DOF-PID Controller for Load Frequency Stabilization in Interconnected Multi-Area Renewable Grids
The Load Frequency Control (LFC) challenge in multi-source power systems increasingly complicates with the integration of renewable energy, owing to frequent nonlinearities, uncertainties, and disturbances. Conventional controllers such as proportional-integral-derivative (PID) and adaptive PI–1PD frequently exhibit constraints in terms of stability and convergence speed. This study proposes an optimal fuzzy logic two-degree-of-freedom PID controller (Optimal–FL–2DOF–PID) tuned via a metaheuristic chess optimizer (CO), which is a novel optimization algorithm introduced in this study. The performance was evaluated in MATLAB/Simulink under two scenarios: (i) a 5% Step Load Perturbation (SLP) and (ii) a Random Step Load Pattern (RSLP) increment-decrement that effectively mirrors real-world applications. The simulation results demonstrate that the Optimal–FL–2DOF–PID controller surpasses all the comparable controllers. In Scenario 1, the proposed controller attains the lowest objective function—Integral of Timeweighted Absolute Error (ITAE) of 4.6692 corresponding to reductions of 25.31%, 43.05%, and 41.92% relative to 2DOF–PID, PID, and PI–1PD, respectively (and 1.92% relative to the None–optimal–FL–2DOF– PID), overshoot (OS), undershoot (US), settling time (ST) 13–15 s, and tie-line power deviations are likewise reduced. In Scenario 2, using the corresponding optimum parameters from Scenario 1, the Optimal–FL– 2DOF–PID controller achieves ITAE = 395.72, which is lower than the None–optimal–FL–2DOF–PID controller design by 46.52%, and lower than 2DOF–PID, PID, and PI–1PD by 29.73%, 22.19%, and 9.68%, respectively. The frequency–channel ST is 150–180 s, whereas tie-line exchanges settled in the mid–150 s with visibly smoother profiles. These results indicate that Optimal–FL–2DOF–PID provides robust and efficient frequency regulation for multi-area systems under significant uncertainty, supporting deployment in future renewable energy-integrated power systems.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 25590-25603
Open AccessChess-Optimized Fuzzy-2DOF-PID Controller for Load Frequency Stabilization in Interconnected Multi-Area Renewable Grids
The Load Frequency Control (LFC) challenge in multi-source power systems increasingly complicates with the integration of renewable energy, owing to frequent nonlinearities, uncertainties, and disturbances. Conventional controllers such as proportional-integral-derivative (PID) and adaptive PI–1PD frequently exhibit constraints in terms of stability and convergence speed. This study proposes an optimal fuzzy logic two-degree-of-freedom PID controller (Optimal–FL–2DOF–PID) tuned via a metaheuristic chess optimizer (CO), which is a novel optimization algorithm introduced in this study. The performance was evaluated in MATLAB/Simulink under two scenarios: (i) a 5% Step Load Perturbation (SLP) and (ii) a Random Step Load Pattern (RSLP) increment-decrement that effectively mirrors real-world applications. The simulation results demonstrate that the Optimal–FL–2DOF–PID controller surpasses all the comparable controllers. In Scenario 1, the proposed controller attains the lowest objective function—Integral of Timeweighted Absolute Error (ITAE) of 4.6692 corresponding to reductions of 25.31%, 43.05%, and 41.92% relative to 2DOF–PID, PID, and PI–1PD, respectively (and 1.92% relative to the None–optimal–FL–2DOF– PID), overshoot (OS), undershoot (US), settling time (ST) 13–15 s, and tie-line power deviations are likewise reduced. In Scenario 2, using the corresponding optimum parameters from Scenario 1, the Optimal–FL– 2DOF–PID controller achieves ITAE = 395.72, which is lower than the None–optimal–FL–2DOF–PID controller design by 46.52%, and lower than 2DOF–PID, PID, and PI–1PD by 29.73%, 22.19%, and 9.68%, respectively. The frequency–channel ST is 150–180 s, whereas tie-line exchanges settled in the mid–150 s with visibly smoother profiles. These results indicate that Optimal–FL–2DOF–PID provides robust and efficient frequency regulation for multi-area systems under significant uncertainty, supporting deployment in future renewable energy-integrated power systems.
- Open Access
- 8 December 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (6) , 28965-28971
Design of a Discontinuous SVPWM Strategy-Based Current Controller in DQ Synchronous Frame for the Grid-Connected 3L-T-Type Inverter
This study proposes an innovative discontinuous Space Vector Pulse Width Modulation (SVPWM) technique integrated with a DQ-based current control scheme for a three-level T-type (3L-T-Type) inverter running in grid-connected mode. The discontinuous modulation technique employs the Nearest Three Vectors (NTVs) from the space vector diagram to provide appropriate switching signals, which substantially decreases the commutation of the Controllable Power Switches (CPSs), thus reducing switching losses. To enhance the output power quality prior to grid injection, a transformation from standard DQ current control to active and reactive Power Control (PQ) is implemented. The proposed method allows for separate control of the d-axis and q-axis components while keeping them in sync with the grid voltage. A mathematical model was developed to compute the stay time of each switching state across different regions and sectors, facilitating the generation of discontinuous modulation waves for each phase leg. The simulation results in MATLAB/Simulink demonstrate improved performance with a 33% reduction in switching commutations, a Total Harmonic Distortion (THD) of 4.67% for the current, proper alignment with the grid voltage at the main frequency of 50 Hz, and effective balancing of the DC-link voltage. These findings confirm the proposed controller's efficacy and its appropriateness for high-performance grid-connected applications, including renewable energy integration and electric vehicle infrastructure.
- 8 December 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (6) , 28965-28971
Open AccessDesign of a Discontinuous SVPWM Strategy-Based Current Controller in DQ Synchronous Frame for the Grid-Connected 3L-T-Type Inverter
This study proposes an innovative discontinuous Space Vector Pulse Width Modulation (SVPWM) technique integrated with a DQ-based current control scheme for a three-level T-type (3L-T-Type) inverter running in grid-connected mode. The discontinuous modulation technique employs the Nearest Three Vectors (NTVs) from the space vector diagram to provide appropriate switching signals, which substantially decreases the commutation of the Controllable Power Switches (CPSs), thus reducing switching losses. To enhance the output power quality prior to grid injection, a transformation from standard DQ current control to active and reactive Power Control (PQ) is implemented. The proposed method allows for separate control of the d-axis and q-axis components while keeping them in sync with the grid voltage. A mathematical model was developed to compute the stay time of each switching state across different regions and sectors, facilitating the generation of discontinuous modulation waves for each phase leg. The simulation results in MATLAB/Simulink demonstrate improved performance with a 33% reduction in switching commutations, a Total Harmonic Distortion (THD) of 4.67% for the current, proper alignment with the grid voltage at the main frequency of 50 Hz, and effective balancing of the DC-link voltage. These findings confirm the proposed controller's efficacy and its appropriateness for high-performance grid-connected applications, including renewable energy integration and electric vehicle infrastructure.
- Open Access
- 8 December 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (6) , 28584-28590
Optimized Machine Learning for Induction Motor Fault Diagnosis Using Vibration and Frequency-Domain Features
This study uses vibration signal analysis to assess and contrast several machine learning models for identifying defects in induction motors. A comprehensive dataset obtained from TDMS-format sensor recordings included seven inter-turn short circuit fault conditions and one normal state. Three experimental settings were investigated: (i) multiclass classification with basic time-domain features, (ii) binary classification using enhanced time and Fast Fourier Transform (FFT) frequency-domain features, and (iii) optimal binary classification using hyperparameter tuning and advanced boosting models. KNN, Random Forest (RF), and ensemble models (XGBoost, LightGBM, CatBoost) were trained and evaluated using accuracy, MSE, RMSE, and R2. The results reveal that while raw time-domain features performed poorly in multiclass tasks (accuracy ~20%), significant gains were obtained utilizing FFT features and binary classification (accuracy up to 80%). Using hyperparameter tuning and gradient boosting techniques, additional enhancements drove the accuracy to 87%, with CatBoost and LightGBM excelling among others. These results highlight the importance of frequency-domain characteristics and model optimization in increasing fault detection dependability. In conclusion, this study helps to encourage the inclusion of intelligent monitoring systems into predictive maintenance pipelines, therefore prolonging the lifetime of industrial equipment and reducing operational downtime.
- 8 December 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (6) , 28584-28590
Open AccessOptimized Machine Learning for Induction Motor Fault Diagnosis Using Vibration and Frequency-Domain Features
This study uses vibration signal analysis to assess and contrast several machine learning models for identifying defects in induction motors. A comprehensive dataset obtained from TDMS-format sensor recordings included seven inter-turn short circuit fault conditions and one normal state. Three experimental settings were investigated: (i) multiclass classification with basic time-domain features, (ii) binary classification using enhanced time and Fast Fourier Transform (FFT) frequency-domain features, and (iii) optimal binary classification using hyperparameter tuning and advanced boosting models. KNN, Random Forest (RF), and ensemble models (XGBoost, LightGBM, CatBoost) were trained and evaluated using accuracy, MSE, RMSE, and R2. The results reveal that while raw time-domain features performed poorly in multiclass tasks (accuracy ~20%), significant gains were obtained utilizing FFT features and binary classification (accuracy up to 80%). Using hyperparameter tuning and gradient boosting techniques, additional enhancements drove the accuracy to 87%, with CatBoost and LightGBM excelling among others. These results highlight the importance of frequency-domain characteristics and model optimization in increasing fault detection dependability. In conclusion, this study helps to encourage the inclusion of intelligent monitoring systems into predictive maintenance pipelines, therefore prolonging the lifetime of industrial equipment and reducing operational downtime.
- Open Access
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (6) , 4900-4912
Load frequency control of multi-source power system using PID+DD controller based on chess algorithm
This article presents load frequency control for a nonlinear multi-source power system divided into three areas, consisting of thermal reheat power plants, hydropower, and wind generation, while considering generation rate constraints (GRC). A proportional–integral–derivative (PID) plus second-order derivative (PID+DD) controller optimized using the chess algorithm (CA) is proposed. The effectiveness of CA is validated against hippopotamus optimization (HO), grey wolf optimizer (GWO), and ant lion optimizer (ALO) under two scenarios: a 10% step load perturbation (SLP) and a random load pattern (RLP). Simulation results indicate that the proposed CA significantly improves dynamic performance. In scenario 1 (10% SLP), CA achieves a reduction of approximately 30.5% in integral weight time absolute error (ITSE) compared to GWO and 43.7% compared to HO, while also reducing frequency undershoot in Area 2 by 15.2% compared to HO. In scenario 2 RLP, CA maintains robustness, limiting tie-line power deviations to ±8 MW, whereas HO exhibits deviations exceeding ±12 MW. Overall, the CA-tuned PID+DD controller demonstrates superior damping, reduced overshoot and undershoot, and enhanced stability across multi-area interconnected renewable systems, making it a promising approach for future real-time load frequency control (LFC) applications with higher renewable penetration.
- 1 December 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (6) , 4900-4912
Open AccessLoad frequency control of multi-source power system using PID+DD controller based on chess algorithm
This article presents load frequency control for a nonlinear multi-source power system divided into three areas, consisting of thermal reheat power plants, hydropower, and wind generation, while considering generation rate constraints (GRC). A proportional–integral–derivative (PID) plus second-order derivative (PID+DD) controller optimized using the chess algorithm (CA) is proposed. The effectiveness of CA is validated against hippopotamus optimization (HO), grey wolf optimizer (GWO), and ant lion optimizer (ALO) under two scenarios: a 10% step load perturbation (SLP) and a random load pattern (RLP). Simulation results indicate that the proposed CA significantly improves dynamic performance. In scenario 1 (10% SLP), CA achieves a reduction of approximately 30.5% in integral weight time absolute error (ITSE) compared to GWO and 43.7% compared to HO, while also reducing frequency undershoot in Area 2 by 15.2% compared to HO. In scenario 2 RLP, CA maintains robustness, limiting tie-line power deviations to ±8 MW, whereas HO exhibits deviations exceeding ±12 MW. Overall, the CA-tuned PID+DD controller demonstrates superior damping, reduced overshoot and undershoot, and enhanced stability across multi-area interconnected renewable systems, making it a promising approach for future real-time load frequency control (LFC) applications with higher renewable penetration.
- Open Access
- 6 October 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (5) , 26517-26522
An ALO-Tuned 2DOF-PID Controller for Enhanced Frequency Regulation in Hybrid PV–Thermal Power Systems
This study investigates the optimization of a two-degree-of-freedom PID (2DOF-PID) controller using the Ant Lion Optimizer (ALO) for enhanced frequency regulation in a hybrid Photovoltaic (PV)–Reheat Thermal Power System under sudden load disturbances. To benchmark performance, conventional PID and PI controllers were also tested to assess their ability to minimize the frequency fluctuations and manage the inter-area power exchanges. Simulations were carried out in MATLAB/Simulink using a dual-area dynamic model, and the performance was evaluated based on standard control metrics, including the settling time, overshoot/undershoot, and the Integral of Absolute Error (IAE). The results indicate that the ALO-optimized 2DOF-PID controller reduced the average settling time by nearly 40% and IAE by 12.6%, compared to the best-performing PID controller in the benchmark group. These findings highlight the advantages of combining the 2DOF-PID architecture with an evolutionary optimization strategy, offering improved dynamic and nonlinear control performance. The proposed approach shows strong potential for application in next-generation renewable energy systems and smart grids.
- 6 October 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (5) , 26517-26522
Open AccessAn ALO-Tuned 2DOF-PID Controller for Enhanced Frequency Regulation in Hybrid PV–Thermal Power Systems
This study investigates the optimization of a two-degree-of-freedom PID (2DOF-PID) controller using the Ant Lion Optimizer (ALO) for enhanced frequency regulation in a hybrid Photovoltaic (PV)–Reheat Thermal Power System under sudden load disturbances. To benchmark performance, conventional PID and PI controllers were also tested to assess their ability to minimize the frequency fluctuations and manage the inter-area power exchanges. Simulations were carried out in MATLAB/Simulink using a dual-area dynamic model, and the performance was evaluated based on standard control metrics, including the settling time, overshoot/undershoot, and the Integral of Absolute Error (IAE). The results indicate that the ALO-optimized 2DOF-PID controller reduced the average settling time by nearly 40% and IAE by 12.6%, compared to the best-performing PID controller in the benchmark group. These findings highlight the advantages of combining the 2DOF-PID architecture with an evolutionary optimization strategy, offering improved dynamic and nonlinear control performance. The proposed approach shows strong potential for application in next-generation renewable energy systems and smart grids.
- Open Access
- 1 October 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (5) , 3429-3438
Improved load frequency control with chess algorithm-driven optimization of 3DOF-PID controller
In contemporary hybrid power systems, persistent load fluctuations disrupt the delicate balance between electrical output and mechanical torque, thereby compromising frequency stability. Load frequency control (LFC) mechanisms are indispensable in maintaining this equilibrium, particularly in systems integrating renewable and thermal energy sources. This study introduces a three-degree-of-freedom proportional-integral-derivative (3DOF-PID) controller optimized via the novel chess optimization algorithm (COA) and evaluates its efficacy against the ant lion optimizer (ALO) and Harris Hawks optimization (HHO). Extensive MATLAB/Simulink simulations were conducted on a hydrothermal system, with performance assessed through objective functions—integral of absolute error (IAE) and integral of time-weighted absolute error (ITAE). The COA consistently yielded the lowest cumulative error values (IAE=0.1548 and ITAE=0.2965), demonstrating its superiority in steady-state performance. However, COA exhibited substantial dynamic deviations, including an overshoot of 387.79% and undershoot of 4513.8% in ∆ftie. Conversely, HHO offered a significantly enhanced transient response, achieving 0% undershoot in ∆ftie with minimal oscillatory behavior. ALO displayed moderate performance but struggled with higher undershoots and prolonged settling time. The findings underscore the criticality of algorithm selection in controller design. While COA excels in minimizing long-term errors, HHO is preferable for applications requiring heightened dynamic stability and responsiveness.
- 1 October 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (5) , 3429-3438
Open AccessImproved load frequency control with chess algorithm-driven optimization of 3DOF-PID controller
In contemporary hybrid power systems, persistent load fluctuations disrupt the delicate balance between electrical output and mechanical torque, thereby compromising frequency stability. Load frequency control (LFC) mechanisms are indispensable in maintaining this equilibrium, particularly in systems integrating renewable and thermal energy sources. This study introduces a three-degree-of-freedom proportional-integral-derivative (3DOF-PID) controller optimized via the novel chess optimization algorithm (COA) and evaluates its efficacy against the ant lion optimizer (ALO) and Harris Hawks optimization (HHO). Extensive MATLAB/Simulink simulations were conducted on a hydrothermal system, with performance assessed through objective functions—integral of absolute error (IAE) and integral of time-weighted absolute error (ITAE). The COA consistently yielded the lowest cumulative error values (IAE=0.1548 and ITAE=0.2965), demonstrating its superiority in steady-state performance. However, COA exhibited substantial dynamic deviations, including an overshoot of 387.79% and undershoot of 4513.8% in ∆ftie. Conversely, HHO offered a significantly enhanced transient response, achieving 0% undershoot in ∆ftie with minimal oscillatory behavior. ALO displayed moderate performance but struggled with higher undershoots and prolonged settling time. The findings underscore the criticality of algorithm selection in controller design. While COA excels in minimizing long-term errors, HHO is preferable for applications requiring heightened dynamic stability and responsiveness.
- Open Access
Design of Two-Degree-of-Freedom PID Controllers Optimized by Bee Algorithm for Frequency Control in Renewable Energy Systems
The increasing incorporation of renewable energy sources, such as photovoltaic and wind power, results in considerable variability and uncertainty within modern power systems, thereby complicating load frequency control. Conventional controllers, including PI and PID, often fail to provide sufficient performance in dynamic conditions. This study introduces a Two-Degree-of-Freedom PID (2DOF-PID) controller optimized through the Bee Algorithm (BA) for Load Frequency Control (LFC) in a two-area interconnected power system that includes renewable energy sources. The BA is employed to enhance controller parameters according to two objective functions: the Integral of Time-weighted Absolute Error (ITAE) and the Integral of Time-weighted Squared Error (ITSE). Simulation studies utilizing MATLAB/Simulink are conducted to evaluate the comparative effectiveness of PI, PID, and 2DOF-PID controllers. The results demonstrate that the 2DOF-PID controller consistently outperforms conventional PI and PID controllers in terms of frequency stability. The ITAE optimization of the 2DOF-PID results in a reduction in the ITAE index by more than 95% compared to PI and PID controllers, a decrease in settling time by approximately 40–60%, and a near elimination of overshoot and undershoot. Through ITSE optimization, the 2DOF-PID achieves an error reduction exceeding 90% and ensures smooth convergence with minimal oscillations. The PID controller has slightly improved effectiveness in minimizing tie-line power deviation, whereas the 2DOF-PID demonstrates greater resilience and damping capability in frequency regulation across both regions. The findings confirm that the Bee Algorithm-tuned 2DOF-PID controller serves as a robust and effective approach for frequency management in systems primarily reliant on renewable energy sources. Future research should incorporate multi-objective optimization algorithms that concurrently address frequency and tie-line power variations, thereby providing a more equitable control framework for practical Automatic Generation Control (AGC) operations.
Open AccessDesign of Two-Degree-of-Freedom PID Controllers Optimized by Bee Algorithm for Frequency Control in Renewable Energy Systems
The increasing incorporation of renewable energy sources, such as photovoltaic and wind power, results in considerable variability and uncertainty within modern power systems, thereby complicating load frequency control. Conventional controllers, including PI and PID, often fail to provide sufficient performance in dynamic conditions. This study introduces a Two-Degree-of-Freedom PID (2DOF-PID) controller optimized through the Bee Algorithm (BA) for Load Frequency Control (LFC) in a two-area interconnected power system that includes renewable energy sources. The BA is employed to enhance controller parameters according to two objective functions: the Integral of Time-weighted Absolute Error (ITAE) and the Integral of Time-weighted Squared Error (ITSE). Simulation studies utilizing MATLAB/Simulink are conducted to evaluate the comparative effectiveness of PI, PID, and 2DOF-PID controllers. The results demonstrate that the 2DOF-PID controller consistently outperforms conventional PI and PID controllers in terms of frequency stability. The ITAE optimization of the 2DOF-PID results in a reduction in the ITAE index by more than 95% compared to PI and PID controllers, a decrease in settling time by approximately 40–60%, and a near elimination of overshoot and undershoot. Through ITSE optimization, the 2DOF-PID achieves an error reduction exceeding 90% and ensures smooth convergence with minimal oscillations. The PID controller has slightly improved effectiveness in minimizing tie-line power deviation, whereas the 2DOF-PID demonstrates greater resilience and damping capability in frequency regulation across both regions. The findings confirm that the Bee Algorithm-tuned 2DOF-PID controller serves as a robust and effective approach for frequency management in systems primarily reliant on renewable energy sources. Future research should incorporate multi-objective optimization algorithms that concurrently address frequency and tie-line power variations, thereby providing a more equitable control framework for practical Automatic Generation Control (AGC) operations.
- Open Access
- 19 June 2025
- Published by ASCEE Publications in International Journal of Robotics and Control Systems
- Vol. 5 (3) , 2053-2067
Chess Optimizer for Load Frequency Control of Three-Area Multi-Source Renewable Energy Based on PID Plus Second Order Derivative Controller
Renewable energy sources such as solar and wind are increasingly integrated into multi-area power systems. However, their fluctuating and unpredictable characteristics pose challenges for sustaining system stability. Therefore, automatic generation control (AGC) is essential for the continual regulation of power and frequency in the system. This article presents the use of a Proportional–Integral–Derivative plus second-order derivative (PID+DD) controller for load frequency control in a three-area multi-source power system, which includes a thermal reheat power plant with a generation rate constraint (GRC) representing the maximum permissible change rate of generation output of 5% per min , a hydroelectric power plant with a GRC of 370% per min, and a wind power plant where wind speeds vary across areas. The power generation ratio of the three areas is 1:2:4. The controller parameters were tuned using a Chess Optimizer (CO), a metaheuristic inspired by chess move complexity and planning, with specific weights assigned to each type of chess piece. Two load change scenarios were studied: a 10% step load perturbation (10% SLP) and a random load pattern (RLP). Furthermore, experimental results based on the Integral of Time-weighted Absolute Error (ITAE) indicate that the PID+DD controller tuned by the Chess Optimizer achieved the lowest steady-state error in both scenarios (10% SLP and RLP). In Case 1 (SLP), it achieved an ITAE of 25.5072, representing a 9.70% reduction compared to the PID controller and a 1.96% reduction compared to the PI controller. In Case 2 (RLP), it achieved an ITAE of 88.0654, representing a 1.14% reduction compared to the PID controller and a 2.03% reduction compared to the PI controller. These improvements contribute to enhanced oscillation damping, reduced overshoot and undershoot, and improved frequency stability, demonstrating the practical applicability of the proposed approach in future smart grids with high renewable energy penetration.
- 19 June 2025
- Published by ASCEE Publications in International Journal of Robotics and Control Systems
- Vol. 5 (3) , 2053-2067
Open AccessChess Optimizer for Load Frequency Control of Three-Area Multi-Source Renewable Energy Based on PID Plus Second Order Derivative Controller
Renewable energy sources such as solar and wind are increasingly integrated into multi-area power systems. However, their fluctuating and unpredictable characteristics pose challenges for sustaining system stability. Therefore, automatic generation control (AGC) is essential for the continual regulation of power and frequency in the system. This article presents the use of a Proportional–Integral–Derivative plus second-order derivative (PID+DD) controller for load frequency control in a three-area multi-source power system, which includes a thermal reheat power plant with a generation rate constraint (GRC) representing the maximum permissible change rate of generation output of 5% per min , a hydroelectric power plant with a GRC of 370% per min, and a wind power plant where wind speeds vary across areas. The power generation ratio of the three areas is 1:2:4. The controller parameters were tuned using a Chess Optimizer (CO), a metaheuristic inspired by chess move complexity and planning, with specific weights assigned to each type of chess piece. Two load change scenarios were studied: a 10% step load perturbation (10% SLP) and a random load pattern (RLP). Furthermore, experimental results based on the Integral of Time-weighted Absolute Error (ITAE) indicate that the PID+DD controller tuned by the Chess Optimizer achieved the lowest steady-state error in both scenarios (10% SLP and RLP). In Case 1 (SLP), it achieved an ITAE of 25.5072, representing a 9.70% reduction compared to the PID controller and a 1.96% reduction compared to the PI controller. In Case 2 (RLP), it achieved an ITAE of 88.0654, representing a 1.14% reduction compared to the PID controller and a 2.03% reduction compared to the PI controller. These improvements contribute to enhanced oscillation damping, reduced overshoot and undershoot, and improved frequency stability, demonstrating the practical applicability of the proposed approach in future smart grids with high renewable energy penetration.