Xiaobo Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaobo Wang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Hongmei Tian
Physics Laboratory, Industrial Training Center, Shenzhen Polytechnic University, Shenzhen, China
2 shared publications - Li Huang
Southern University of Science and Technology
2 shared publications Baoshun Zhang
Key Laboratory of Multifunctional Nanomaterials and Smart Systems, Suzhou Institute of Nano-Tech and Nano-Bionics
1 shared publication- Guowen Kuang
Institute of Applied Artificial Intelligence of the Guangdong-Hong Kong-Macao Greater Bay Area, Shenzhen Polytechnic University, Shenzhen 518055, China
1 shared publication Hongmei Tian
Physics Laboratory, Industrial Training Center
1 shared publicationMiaomiao Tian
Hyde School of Nanshan Second Foreign Languages School(Group), Shenzhen, China
1 shared publication
Latest Publications
- Open Access
- 6 October 2026
- Published by Springer Nature in Microsystem Technologies
- Vol. 32 (12) , 191
Tunable graphene-integrated metasurface biosensor with hybrid plasmonic-2D material coupling for dual cancer detection in terahertz regime
This study presents a vertically integrated terahertz metasurface biosensor that combines graphene with transition metal dichalcogenides for breast and colorectal cancer detection based on refractive index sensing. The resonant region uses a clustered cross geometry composed of four hollow circular rings and four solid circular resonators linked by orthogonal MoS2-coated rectangular strips on a graphene layer. Selected regions are coated with silver, gold, and copper, along with WS 2 , WSe 2 , and MoSe 2 , to control the electromagnetic response over 0.19 to 0.72 THz. Simulated absorption exceeds 98%. Resonance frequency tuning is accomplished by varying the graphene chemical potential between 0.1 and 0.9 eV and modifying the structure’s geometric parameters. For breast cancer detection, the sensor exhibits a sensitivity of 1000 GHz per RIU over refractive indices ranging from 1.385 to 1.401 RIU. Comparable sensitivity is observed for colorectal cancer detection within the 1.329 to 1.348 RIU range. The reported quality factors span from 1.5 to 1.63, yielding figures of merit up to 6.45 RIU⁻¹ and a minimum detection limit of 0.365. A Random Forest regression model predicts the sensor’s response under variations in incident angle and resonator geometry, achieving $$\:{R}^{2}>0.9996$$ and a root mean squared error below 0.003 across the evaluated dataset. Electric field simulations show frequency-dependent field concentration in the sensing region, which supports differentiation between dielectric properties assigned to healthy and malignant tissues in the model. The design uses electrically tunable graphene conductivity and multilayer material coupling to modify resonance behavior in a single device intended for label-free terahertz biosensing.- 6 October 2026
- Published by Springer Nature in Microsystem Technologies
- Vol. 32 (12) , 191
Open AccessTunable graphene-integrated metasurface biosensor with hybrid plasmonic-2D material coupling for dual cancer detection in terahertz regime
This study presents a vertically integrated terahertz metasurface biosensor that combines graphene with transition metal dichalcogenides for breast and colorectal cancer detection based on refractive index sensing. The resonant region uses a clustered cross geometry composed of four hollow circular rings and four solid circular resonators linked by orthogonal MoS2-coated rectangular strips on a graphene layer. Selected regions are coated with silver, gold, and copper, along with WS 2 , WSe 2 , and MoSe 2 , to control the electromagnetic response over 0.19 to 0.72 THz. Simulated absorption exceeds 98%. Resonance frequency tuning is accomplished by varying the graphene chemical potential between 0.1 and 0.9 eV and modifying the structure’s geometric parameters. For breast cancer detection, the sensor exhibits a sensitivity of 1000 GHz per RIU over refractive indices ranging from 1.385 to 1.401 RIU. Comparable sensitivity is observed for colorectal cancer detection within the 1.329 to 1.348 RIU range. The reported quality factors span from 1.5 to 1.63, yielding figures of merit up to 6.45 RIU⁻¹ and a minimum detection limit of 0.365. A Random Forest regression model predicts the sensor’s response under variations in incident angle and resonator geometry, achieving $$\:{R}^{2}>0.9996$$ and a root mean squared error below 0.003 across the evaluated dataset. Electric field simulations show frequency-dependent field concentration in the sensing region, which supports differentiation between dielectric properties assigned to healthy and malignant tissues in the model. The design uses electrically tunable graphene conductivity and multilayer material coupling to modify resonance behavior in a single device intended for label-free terahertz biosensing. - Open Access
- 18 October 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (42) , 49766-49775
Artificial Synapse Based on Black Phosphorus/SnS 2 Heterostructure Transistor for Neuromorphic Computing with High Accuracy
Artificial synaptic devices have garnered significant attention for overcoming the limitations of conventional von Neumann architecture in neuromorphic computing. However, the reported nonlinear weight update of artificial synapses prevents a hardware neural network from achieving the same high training and learning accuracy levels as those attained by a soft neural work. Despite the large-area fabrication constraints, two-dimensional (2D) materials that have tunable electronic band alignment and optoelectronic properties have emerged as promising candidates for artificial synapses. Here, we demonstrate an artificial synaptic device based on a black phosphorus (BP)/SnS2 van der Waals heterostructure. This device achieves a large memory window and successfully emulates various synaptic functionalities. Notably, the nonlinearity in the synaptic weight update of this device can be electrically modulated, and the underlying mechanism is analyzed by density functional theory (DFT) calculations. Furthermore, we successfully integrate BP/SnS2-based artificial synapses into an artificial neural network, achieving a high recognition accuracy of 96.3% on the MNIST data set for handwritten digit recognition. These findings introduce an effective method for high-accuracy neuromorphic applications through the band structure engineering of 2D materials.
- 18 October 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (42) , 49766-49775
Open AccessArtificial Synapse Based on Black Phosphorus/SnS 2 Heterostructure Transistor for Neuromorphic Computing with High Accuracy
Artificial synaptic devices have garnered significant attention for overcoming the limitations of conventional von Neumann architecture in neuromorphic computing. However, the reported nonlinear weight update of artificial synapses prevents a hardware neural network from achieving the same high training and learning accuracy levels as those attained by a soft neural work. Despite the large-area fabrication constraints, two-dimensional (2D) materials that have tunable electronic band alignment and optoelectronic properties have emerged as promising candidates for artificial synapses. Here, we demonstrate an artificial synaptic device based on a black phosphorus (BP)/SnS2 van der Waals heterostructure. This device achieves a large memory window and successfully emulates various synaptic functionalities. Notably, the nonlinearity in the synaptic weight update of this device can be electrically modulated, and the underlying mechanism is analyzed by density functional theory (DFT) calculations. Furthermore, we successfully integrate BP/SnS2-based artificial synapses into an artificial neural network, achieving a high recognition accuracy of 96.3% on the MNIST data set for handwritten digit recognition. These findings introduce an effective method for high-accuracy neuromorphic applications through the band structure engineering of 2D materials.
- Open Access
- 21 November 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (23) , 1868
Investigation of Buckling Behaviors in Carbon Nanorings Using the Chebyshev–Ritz Method
Carbon nanorings (CNRs) serve as an ideal quantum system for novel electronic and magnetic properties. Although extensive theoretical studies utilizing molecular dynamics (MD) simulations have investigated the formation and structural characteristics of CNRs, systematically analyzing their properties across various toric sizes remains challenging due to the inherent complexity of this system. In this study, we introduce a novel finite element method, the Chebyshev–Ritz method, as an alternative approach to investigating the structural properties of CNRs. Previous MD simulations demonstrated that stable CNRs adopt a regular buckled shape at specific toric sizes. By meticulously selecting mechanical parameters, we observe that the critical deformation of a CNR with 50 repeated units, as determined by the Chebyshev–Ritz method, aligns with an MD simulation presenting a buckling number of 14. Additionally, the implementation of the Chebyshev–Ritz method with a constant mechanical parameter for 50 repeated units reveals a structural transition at varying toric sizes, leading to the stabilization of buckling numbers 13, 14, and 15. This structural transition across different buckling modes has also been corroborated by MD simulations. Our approach offers a reliable and accurate means of examining the structural properties of large-scale nanomaterials and paves the way for further exploration in nanoscale mechanics.
- 21 November 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (23) , 1868
Open AccessInvestigation of Buckling Behaviors in Carbon Nanorings Using the Chebyshev–Ritz Method
Carbon nanorings (CNRs) serve as an ideal quantum system for novel electronic and magnetic properties. Although extensive theoretical studies utilizing molecular dynamics (MD) simulations have investigated the formation and structural characteristics of CNRs, systematically analyzing their properties across various toric sizes remains challenging due to the inherent complexity of this system. In this study, we introduce a novel finite element method, the Chebyshev–Ritz method, as an alternative approach to investigating the structural properties of CNRs. Previous MD simulations demonstrated that stable CNRs adopt a regular buckled shape at specific toric sizes. By meticulously selecting mechanical parameters, we observe that the critical deformation of a CNR with 50 repeated units, as determined by the Chebyshev–Ritz method, aligns with an MD simulation presenting a buckling number of 14. Additionally, the implementation of the Chebyshev–Ritz method with a constant mechanical parameter for 50 repeated units reveals a structural transition at varying toric sizes, leading to the stabilization of buckling numbers 13, 14, and 15. This structural transition across different buckling modes has also been corroborated by MD simulations. Our approach offers a reliable and accurate means of examining the structural properties of large-scale nanomaterials and paves the way for further exploration in nanoscale mechanics.