LALeon Au

Leon Au

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Leon Au has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A New “Tube-in-tube” Method to Extend Glaucoma Drainage Devices Using Paul Glaucoma Implant

    by Leon Au, Tasmin Berman

    To describe a novel and uncomplicated technique of elongating the tubing of a glaucoma drainage device (GDD) sourced from a segment of the tube from a Paul® Glaucoma Implant (PGI). Conjunctival and Tenon's peritomy are performed with relaxing incisions to expose the original tube. The original tube is then removed from the anterior chamber, and the original entry site is closed. The tip of the original Baerveldt/Ahmed tubing is shortened to near the plate, and the lumen is stretched open using Burke's forceps (nontoothed to avoid damage to the tubing) while the appropriate length of the Paul tube was being pushed inside and is secure without the need for any suturing. The new smaller Paul tube is then inserted back into the anterior chamber using a 26-gauge tract. An 8-0 Ethilon® was then used to secure the tube to the sclera, and TISSEL® was used to secure it (Baxter, United States). Depending on the positioning, either the original Tutoplast® pericardium or new double-layered Tutoplast® can be placed over the tube to prevent erosion. The Tenon's and conjunctiva were then closed to secure the conjunctival and Tenon's back in their original position at the limbus, and the radial conjunctival incisions can be closed using TISSEL® fibrin glue or further sutures if required. This method offers several benefits over previously documented techniques; it avoids significant bulkiness, and the elongated tube conforms to the curvature of the globe owing to the suitable rigidity of the extended section. The additional tubing segment fits securely without the need for sutures. Introducing a smaller diameter tube into the anterior chamber in comparison to other GDDs minimizes the surface area between the tube and corneal endothelium, therefore decreasing the rate of potential endothelium cell loss. This novel “tube-in-tube” technique is efficient, safe, and straightforward to perform. It eliminates the need for alterations in glaucoma medication since the PGI is not thought to offer any flow resistance. Berman T, Au L. A New “Tube-in-tube” Method to Extend Glaucoma Drainage Devices Using Paul Glaucoma Implant. J Curr Glaucoma Pract 2024;18(3):130–133.


  • Outcomes of Primary Trabeculectomy From Two Same-centre Cohorts 10 Years Apart

    by Haaris A. Mb Shiwani, Salman Frcophth Naqvi, Cristina Mbbs Cristian, Leon Frcophth Au, Anne F. Frcophth Spencer, Cecilia H. Frcophth Fenerty, Karl J. Frcophth Mercieca

    Precis: Trabeculectomy can effectively lower intraocular pressure (IOP). A more junior surgeon profile is emerging. Mitomycin C (MMC) has replaced 5-fluorouracil (5-FU) intraoperatively with comparable success rates and a decrease in postoperative antimetabolite administration. Purpose: We compare 2-year outcomes for primary trabeculectomy in 2 cohorts, 10 years apart, performed at a large UK teaching hospital. Methods: Consecutive case series of trabeculectomies at Manchester Royal Eye Hospital between 2004-2005 (Cohort 1/C1) and 2014-2015 (Cohort 2/C2). Preoperative and postoperative data was collected for IOP outcomes and complications. Success was defined as IOP ≥6 and ≤21, ≤18, ≤16, ≤14, or ≤12 mm Hg with/without a ≥20% decrease from preoperative IOP. The need for and absence of postoperative antihypertensive medication defined qualified and complete success, respectively. Results: A total of 186 cases were analyzed [52 (C1), 134 (C2)]. Mean preoperative IOP was 24±10 mm Hg (C1) and 21±7 mm Hg (C2) (P=0.01). Overall, 34 (79%), 33 (77%), 33 (77%), 29 (67%), and 25 (58%) patients in C1 and 88 (70%), 82 (65%), 73 (58%), 64 (51%), and 40 (32%) patients in C2 achieved complete success for IOP ≤21 mm Hg (P=0.33), ≤18 mm Hg (P=0.22), ≤16 mm Hg (P=0.04), ≤14 mm Hg (P=0.09), or ≤12 mm Hg (P=0.004). Similarly, 43 (93%), 40 (87%), 40 (87%), 35 (76%), and 27 (59%) in C1 and 123 (98%), 116 (92%), 106 (84%), 87 (69%), and 58 (49%) in C2 achieved qualified success (P=0.34, 0.37, 0.83, 0.48, and 0.19). In all, 32 (74%), 31 (72%),31 (72%), 28 (65%), and 24 (56%) in C1 and 64 (51%), 63 (50%), 61 (48%), 54 (43%), and 39 (31%) in C2 achieved complete success with ≥20% reduction from preoperative IOP and IOP of ≤21 mm Hg (P=0.01), ≤18 mm Hg (P=0.02), ≤16 mm Hg (P=0.01), ≤1 mm Hg (P=0.02), or ≤12 mm Hg (P=0.006). By same definition, 37 (80%), 36 (78%), 36 (78%), 33 (72%), and 26 (57%) in C1 and 94 (75%), 93 (74%), 90 (71%), 75 (60%), and 58 (46%) in C2 achieved qualified success (P=0.55, 0.69, 0.48, 0.20, and 0.30). Mean IOP at 2 years was 13±5 mm Hg (C1) and 13±4 mm Hg (C2) (P=0.35). Overall, 62% had intraoperative 5-FU in C1; only MMC was used in C2 (PPP=0.22). Conclusions: Trabeculectomy is effective in lowering IOP with success comparable across various definitions. MMC replaced 5-FU as intraoperative antimetabolite resulting in reduced need for postoperative antimetabolite but not increased complications.


  • Conjunctival bleb compression sutures: An effective method of addressing hypotony after trabeculectomy or trabeculectomy-related procedures

    by Jonathan Ts Yu, Karl Mercieca, Leon Au

    Purpose: Over-filtration is a well-known complication of trabeculectomy and related procedures, especially with adjunctive antimetabolites. Secondary hypotony can result in reduced visual acuity and compromise long-term surgical success. Persistent hypotony requires intervention and we describe an effective adaptation of placing conjunctival compression sutures directly over the scleral flap. Methods: A retrospective consecutive case series of all patients who underwent conjunctival compression suturing from 2012 to 2014 at Manchester Royal Eye Hospital, UK. Under sub-tenon’s anaesthesia, two 9/0 nylon figure-of-eight transconjunctival sutures were placed horizontally across the bleb: the first over the anterior flap/ostium and the second over the posterior flap edge to reduce flow through the trabeculectomy flap. Results: A total of 10 patients underwent conjunctival compression suturing, and all patients had successful reversal of hypotony and symptom resolution within 1 week with corresponding clinical improvement. Intraocular pressure control was maintained without topical pressure-lowering agents in seven patients (median = 10 mmHg, range = 7–12 mmHg) with a median follow-up of 35.9 months (range = 11–61 months). Two patients required topical therapy to maintain intraocular pressure ≤ 14 mmHg and one patient’s hypotony returned after 10 months but remained untreated due to pre-existing poor vision. No patients required a return to theatre. Conclusion: This series demonstrates that conjunctival compression sutures can successfully provide long-term control of trabeculectomy-bleb-related hypotony. This technique offers an effective alternative for glaucoma surgeons in addressing post-trabeculectomy hypotony.


  • Outcome of Bleb Revision Using Scleral Patch Graft and Conjunctival Advancement

    by Leon Au, David Wechsler, Fiona Spencer, Cecilia Fenerty

    To evaluate our surgical technique of bleb revision using scleral patch graft and conjunctival advancement, the long-term outcome and the ability to maintain adequate intraocular pressure (IOP) control. Retrospective review. Eighteen patients were identified. The mean age was 72.1+/-4.3 years (95% confidence limits). In 12 of the 18 cases, the posterior edge of scleral patch graft was secured with fixed sutures, in another 3 with releasable sutures and in the remaining 3 with adjustable sutures. The mean follow-up period was 23.7+/-5.4 months (95% confidence limits). The mean preoperative IOP was 7.6+/-3.0 mm Hg (95% confidence limits), increased to 13.1+/-1.6 mm Hg (P=0.02) postoperatively. Twelve of the 18 patients had a minimum of 2-year follow-up. At this time point, 7 out of 12 (58%) patients had IOP <21 mm Hg without any medication, 9 out of 12 (75%) patients had IOP <21 mm Hg with medication, 7 out of 12 (58%) patients had IOP <16 mm Hg without medication, and 9 out of 12 (75%) had IOP <16 mm Hg with medication. The mean number of 5-fluorouracil injections with or without needling was significantly higher in the success group than in the failure group (P=0.035). This series illustrates a useful technique using a scleral patch graft in cases of full-thickness scleral defect encountered during bleb revisions. The success rates achieved are comparable to those in the published literature, and furthermore our successful cases achieved lower IOPs appropriate for patients with advanced glaucoma.