Corinne Isenegger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Corinne Isenegger has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Patrick Badertscher
Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, Basel, Switzerland
15 shared publications Christian Sticherling
Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, Basel, Switzerland
10 shared publicationsMichael Kühne
Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, Basel, Switzerland
10 shared publicationsBehnam Subin
Department of Cardiology, University Hospital Basel, University of Basel , Petersgraben 4, Basel 4031
8 shared publicationsDavid Spreen
Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, Basel, Switzerland
8 shared publicationsFabian Jordan
Department of Cardiology, University Hospital Basel, Basel, Switzerland; Cardiovascular Research Institute Basel, University Hospital Basel, Basel, Switzerland
8 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (9)
Pulsed-field ablation for atrial fibrillation with an extended protocol: the extended PFA dose study
- 2 September 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (9)
Open AccessPulsed-field ablation for atrial fibrillation with an extended protocol: the extended PFA dose study
- Open Access
- 3 July 2026
- Published by Elsevier in Heart Rhythm
Pulsed-Field Ablation with Two Different-Sized Pentaspline Catheters in Patients with Atrial Fibrillation
- 3 July 2026
- Published by Elsevier in Heart Rhythm
Open AccessPulsed-Field Ablation with Two Different-Sized Pentaspline Catheters in Patients with Atrial Fibrillation
- Open Access
- 8 January 2026
- Published by Elsevier in Heart Rhythm
- Vol. 23 (4) , 829-835
Impact of left atrial posterior wall isolation using pulsed-field ablation in patients undergoing repeat catheter ablation for atrial fibrillation
- 8 January 2026
- Published by Elsevier in Heart Rhythm
- Vol. 23 (4) , 829-835
Open AccessImpact of left atrial posterior wall isolation using pulsed-field ablation in patients undergoing repeat catheter ablation for atrial fibrillation
- Open Access
- 23 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (11)
Anterior mitral isthmus line using pulsed-field ablation with the pentaspline catheter or radiofrequency ablation: procedural characteristics, safety, and mid-term outcomes
Aims: Pulsed-field ablation (PFA) is a non-thermal energy source for pulmonary vein isolation (PVI), offering advantages in safety and procedural efficiency. However, data comparing anterior mitral isthmus line (MIL) ablation using PFA vs. conventional radiofrequency ablation (RFA) are scarce. This study aimed to compare procedural characteristics, safety, and arrhythmia recurrence following PVI with additional anterior MIL ablation using PFA vs. RFA. Methods and results: In this prospective, single-centre analysis from the SWISS-AF-PVI registry, 129 patients (median age 70 years, 40% female) undergoing PVI with anterior MIL ablation were included. Patients received either PFA with a pentaspline catheter (n = 61) or RFA using a 3.5 mm irrigated tip catheter (n = 68). Procedural parameters, complications, and arrhythmia recurrence were assessed over a median follow-up of 327 days. PFA significantly reduced total procedure time (71 vs. 108 min, P < 0.001), LA dwell time (53 vs. 80 min, P < 0.001), and ablation time (27 vs. 50 min, P < 0.001) compared to RFA. MIL ablation with PFA required fewer applications (14; 35 s vs. 473 s RFA, P < 0.001). Arrhythmia-free survival was similar between groups (PFA 48.8% vs. RFA 61.8%, P = 0.34). Among 34 patients undergoing redo procedures, incomplete MIL was found in 53%, with no significant difference between groups. Three major complications occurred. Conclusion: Anterior MIL ablation using PFA is feasible, safe, and more time-efficient than RFA, with comparable mid-term arrhythmia outcomes. However, high rates of MIL reconnection and arrhythmia recurrence highlights the need to improve lesion durability.
- 23 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (11)
Open AccessAnterior mitral isthmus line using pulsed-field ablation with the pentaspline catheter or radiofrequency ablation: procedural characteristics, safety, and mid-term outcomes
Aims: Pulsed-field ablation (PFA) is a non-thermal energy source for pulmonary vein isolation (PVI), offering advantages in safety and procedural efficiency. However, data comparing anterior mitral isthmus line (MIL) ablation using PFA vs. conventional radiofrequency ablation (RFA) are scarce. This study aimed to compare procedural characteristics, safety, and arrhythmia recurrence following PVI with additional anterior MIL ablation using PFA vs. RFA. Methods and results: In this prospective, single-centre analysis from the SWISS-AF-PVI registry, 129 patients (median age 70 years, 40% female) undergoing PVI with anterior MIL ablation were included. Patients received either PFA with a pentaspline catheter (n = 61) or RFA using a 3.5 mm irrigated tip catheter (n = 68). Procedural parameters, complications, and arrhythmia recurrence were assessed over a median follow-up of 327 days. PFA significantly reduced total procedure time (71 vs. 108 min, P < 0.001), LA dwell time (53 vs. 80 min, P < 0.001), and ablation time (27 vs. 50 min, P < 0.001) compared to RFA. MIL ablation with PFA required fewer applications (14; 35 s vs. 473 s RFA, P < 0.001). Arrhythmia-free survival was similar between groups (PFA 48.8% vs. RFA 61.8%, P = 0.34). Among 34 patients undergoing redo procedures, incomplete MIL was found in 53%, with no significant difference between groups. Three major complications occurred. Conclusion: Anterior MIL ablation using PFA is feasible, safe, and more time-efficient than RFA, with comparable mid-term arrhythmia outcomes. However, high rates of MIL reconnection and arrhythmia recurrence highlights the need to improve lesion durability.
- Open Access
- 7 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (10)
Feasibility and accuracy of wearable electrocardiogram monitoring in adult congenital heart disease
- 7 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (10)
Open AccessFeasibility and accuracy of wearable electrocardiogram monitoring in adult congenital heart disease
- Open Access
- 19 September 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (11) , 2955-2962
Comparison of Two Different Pulsed Field Ablation Systems: The Dual Pulse System Study
Background: Recently, multiple pulsed field ablation (PFA)‐system were introduced for catheter ablation (CA) of atrial fibrillation (AF). However, data comparing procedural performance, the extent of low‐voltage areas (LVA), and myocardial injury between different PFA‐systems in a real‐world setting remain scarce. Methods: Consecutive patients undergoing CA for AF were enrolled. PFA was performed using either a Pentaspline catheter‐system (PCS) or a loop catheter‐system (LCS). The extent of acute antral LVA was assessed using a 3D‐electroanatomical mapping system. High‐sensitivity cardiac troponin T (hs‐cTnT) was measured the day after the procedure to assess myocardial injury. Results: A total of 120 patients (median age 67 [59–73] years, 29% female) underwent de novo pulmonary vein isolation (PVI). The PCS‐group included 90 patients, while the LCS‐group included 30 patients. Acute PVI was achieved in all patients (100%). Procedural times were significantly shorter in the PCS compared to the LCS‐group, including total procedure duration (57 [48–67] vs 66 [52–83] min, p = 0.016), left atrial dwell time (38 [32–48] vs 54 [38–65] min, p < 0.001), and ablation duration (17 [12–23] vs 24 [20–33] min, p < 0.001). Acute antral LVA and myocardial injury were significantly lower in the PCS compared to the LCS‐group (6.6 [5.0–8.9] vs. 19.2 [16.8–25.4] cm², p < 0.001 and hs‐cTnT of 1282 [892–1894] vs 1588 [1281–2110] ng/L, p = 0.029. Conclusion: Significant differences were observed between two commercially available PFA‐systems. While PCS was associated with significantly shorter procedural time, LCS resulted in a greater extent of acute antral LVA and myocardial injury levels.
- 19 September 2025
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 36 (11) , 2955-2962
Open AccessComparison of Two Different Pulsed Field Ablation Systems: The Dual Pulse System Study
Background: Recently, multiple pulsed field ablation (PFA)‐system were introduced for catheter ablation (CA) of atrial fibrillation (AF). However, data comparing procedural performance, the extent of low‐voltage areas (LVA), and myocardial injury between different PFA‐systems in a real‐world setting remain scarce. Methods: Consecutive patients undergoing CA for AF were enrolled. PFA was performed using either a Pentaspline catheter‐system (PCS) or a loop catheter‐system (LCS). The extent of acute antral LVA was assessed using a 3D‐electroanatomical mapping system. High‐sensitivity cardiac troponin T (hs‐cTnT) was measured the day after the procedure to assess myocardial injury. Results: A total of 120 patients (median age 67 [59–73] years, 29% female) underwent de novo pulmonary vein isolation (PVI). The PCS‐group included 90 patients, while the LCS‐group included 30 patients. Acute PVI was achieved in all patients (100%). Procedural times were significantly shorter in the PCS compared to the LCS‐group, including total procedure duration (57 [48–67] vs 66 [52–83] min, p = 0.016), left atrial dwell time (38 [32–48] vs 54 [38–65] min, p < 0.001), and ablation duration (17 [12–23] vs 24 [20–33] min, p < 0.001). Acute antral LVA and myocardial injury were significantly lower in the PCS compared to the LCS‐group (6.6 [5.0–8.9] vs. 19.2 [16.8–25.4] cm², p < 0.001 and hs‐cTnT of 1282 [892–1894] vs 1588 [1281–2110] ng/L, p = 0.029. Conclusion: Significant differences were observed between two commercially available PFA‐systems. While PCS was associated with significantly shorter procedural time, LCS resulted in a greater extent of acute antral LVA and myocardial injury levels.
- Open Access
- 4 August 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (8)
Comparative analysis of newest-generation variable-diameter cryoballoon with pulsed-field ablation for the treatment of atrial fibrillation: the CRYO-PULSE Study
- 4 August 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (8)
Open AccessComparative analysis of newest-generation variable-diameter cryoballoon with pulsed-field ablation for the treatment of atrial fibrillation: the CRYO-PULSE Study
- Open Access
- 8 July 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (10) , 1483-1490
Pulsed-field ablation versus radiofrequency ablation in patients undergoing repeat catheter ablation for atrial fibrillation
- 8 July 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (10) , 1483-1490
Open AccessPulsed-field ablation versus radiofrequency ablation in patients undergoing repeat catheter ablation for atrial fibrillation
- Open Access
- 18 June 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (9) , 2003-2011
Inconclusive Single-Lead ECGs From Smart-Devices
- 18 June 2025
- Published by Elsevier in JACC: Clinical Electrophysiology
- Vol. 11 (9) , 2003-2011
Open AccessInconclusive Single-Lead ECGs From Smart-Devices
- Open Access
- 17 May 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (8) , 1229-1231
Catheter ablation for atrial fibrillation in patients with tricuspid regurgitation
- 17 May 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (8) , 1229-1231
Open AccessCatheter ablation for atrial fibrillation in patients with tricuspid regurgitation