Duygu Harmankaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Duygu Harmankaya has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Marco J. Bruno
Department of Gastroenterology and Hepatology, Erasmus MC - University Medical Centre Rotterdam, The Netherlands
3 shared publicationsDesirée van Noord
Department of Gastroenterology and Hepatology, Franciscus Gasthuis and Vlietland, Rotterdam, The Netherlands
2 shared publications- Flores M. Metz
Department of Vascular Surgery, Medisch Spectrum Twente, Enschede, the Netherlands; Multi-Modality Medical Imaging Group, TechMed Centre, University Twente, Enschede, the Netherlands
2 shared publications - Marjolein Brusse-Keizer
Medical School Twente, Medisch Spectrum Twente, Enschede, Netherlands
2 shared publications Bob H. Geelkerken
Department of Vascular Surgery, Medisch Spectrum Twente, Enschede, the Netherlands; Multi-Modality Medical Imaging Group, TechMed Centrum, University Twente, Enschede, the Netherlands
1 shared publicationDesiree van Noord
Department of Gastroenterology and Hepatology, Franciscus Gasthuis and Vlietland, Rotterdam, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 3 November 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 72 (1) , 53-61
Quest for Successful Outcome Determinants of Video Assisted Retroperitoneal Coeliac Artery Release in Patients with Median Arcuate Ligament Syndrome: Retrospective Single Centre Study Based on Prospectively Collected Data
- 3 November 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 72 (1) , 53-61
Open AccessQuest for Successful Outcome Determinants of Video Assisted Retroperitoneal Coeliac Artery Release in Patients with Median Arcuate Ligament Syndrome: Retrospective Single Centre Study Based on Prospectively Collected Data
- Open Access
- 13 October 2025
- Published by Springer Nature in Research Square
Effects of catheter sizing on pressure gradient measurements in a model of vessel stenosis
Introduction Current clinical practice lacks reliable diagnostic tools for Chronic Mesenteric Ischemia (CMI), often relying on symptom relief post-recanalization for definitive diagnosis. Mesenteric artery pressure gradients (PG) during intervention offer insight into the hemodynamic significance of mesenteric artery stenosis (MAS) and potential compensatory collateral circulation. This study aims to compare the differences in PG measurements obtained with a macrocatheter, microcatheter, and pressure wire across varying degrees of stenosis, using an in-vitro model of the two most commonly stented mesenteric arteries: the celiac artery (CA) and superior mesenteric artery (SMA). Materials and Methods Using an in-vitro model, we simulated postprandial states in the superior mesenteric artery (SMA) and celiac artery (CA), measuring flow rates across 24 3D printed stenoses with a macrocatheter, microcatheter and pressure wire. Fractional Flow Reserve (FFR) quantified the effects of catheter sizing on pressure gradient measurements. Results Reliability of FFR measurements using a macrocatheter was lower in stenosis exceeding 75% as well as longer stenosis as it tends to overestimate hemodynamic significance of MAS and underestimates collateral circulation compensation mechanisms, whereas the macrocatheter consistently shows a larger variability compared to the microcatheter and pressure wire in each stenosis category (5 mm, 10 mm, 15 mm, and 20 mm). Conclusions For stenoses ≤ 75%, microcatheter, macrocatheter, and pressure wire are comparable in assessing FFR. However, caution is warranted for stenoses > 75% or longer stenoses, as macrocatheter tends to overestimate FFR. Considering applicability and costs, microcatheter is recommended for clinical use.
- 13 October 2025
- Published by Springer Nature in Research Square
Open AccessEffects of catheter sizing on pressure gradient measurements in a model of vessel stenosis
Introduction Current clinical practice lacks reliable diagnostic tools for Chronic Mesenteric Ischemia (CMI), often relying on symptom relief post-recanalization for definitive diagnosis. Mesenteric artery pressure gradients (PG) during intervention offer insight into the hemodynamic significance of mesenteric artery stenosis (MAS) and potential compensatory collateral circulation. This study aims to compare the differences in PG measurements obtained with a macrocatheter, microcatheter, and pressure wire across varying degrees of stenosis, using an in-vitro model of the two most commonly stented mesenteric arteries: the celiac artery (CA) and superior mesenteric artery (SMA). Materials and Methods Using an in-vitro model, we simulated postprandial states in the superior mesenteric artery (SMA) and celiac artery (CA), measuring flow rates across 24 3D printed stenoses with a macrocatheter, microcatheter and pressure wire. Fractional Flow Reserve (FFR) quantified the effects of catheter sizing on pressure gradient measurements. Results Reliability of FFR measurements using a macrocatheter was lower in stenosis exceeding 75% as well as longer stenosis as it tends to overestimate hemodynamic significance of MAS and underestimates collateral circulation compensation mechanisms, whereas the macrocatheter consistently shows a larger variability compared to the microcatheter and pressure wire in each stenosis category (5 mm, 10 mm, 15 mm, and 20 mm). Conclusions For stenoses ≤ 75%, microcatheter, macrocatheter, and pressure wire are comparable in assessing FFR. However, caution is warranted for stenoses > 75% or longer stenoses, as macrocatheter tends to overestimate FFR. Considering applicability and costs, microcatheter is recommended for clinical use.
- Open Access
- 16 November 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 69 (4) , 628-637
Mesenteric Artery Stenosis is a Risk Factor for Anastomotic Leakage in Colorectal Surgery
- 16 November 2024
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 69 (4) , 628-637
Open AccessMesenteric Artery Stenosis is a Risk Factor for Anastomotic Leakage in Colorectal Surgery