Nolan M. Reinhart
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nolan M. Reinhart has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- William F. Sherman
Department of Orthopaedic Surgery, Tulane University School of Medicine, New Orleans, LA, USA
5 shared publications - Jackson P. Tate
Department of Orthopaedic Surgery, Tulane University School of Medicine, 1430 Tulane Ave, New Orleans, Louisiana, 70112, USA
4 shared publications Jackson P. Tate
Tulane University School of Medicine, New Orleans, Louisiana, USA
2 shared publications- Olivia C. Lee
Department of Orthopaedic Surgery, Louisiana State University Health Sciences Center School of Medicine, New Orleans, LA, USA
2 shared publications - Akshar H. Patel
Tulane University School of Medicine
1 shared publication - Andrew M. Gabig1 shared publication
Latest Publications
- Open Access
- 15 September 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (9)
Cartilage Conundrum: Investigating Outcomes in Knee Cartilage Restoration Techniques
Background: Management of chondral injury can be difficult due to the avascularity of articular cartilage and the limited ability to proliferate and promote repair. Untreated lesions can lead to early development of arthritis and the need for joint replacement. For intermediate-sized lesions, osteochondral autograft transfer and autologous cell-based cartilage treatment have been accepted as the most effective treatment options. Purpose: To investigate the rates of complications within 2 years of initial surgery in patients who undergo primary autologous cell-based cartilage treatment and osteochondral autograft. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective cohort study was performed on July 17, 2024, using a commercially available insurance claims database to investigate 2-year orthopaedic complication rates in 1298 patients after primary osteochondral autograft and autologous cell-based cartilage treatment for chondral injuries of the knee. Patient cohorts were propensity score matched with a caliper set to 0.2 at a ratio of 1 to 1 on the following variables: age, sex, diabetes, and tobacco use. Rates of surgical complications were compared using multivariable logistic regression, adjusted for age, sex, diabetes, obesity, and tobacco use. Odds ratios (ORs) with corresponding 95% CIs were calculated for each comparison. Results: A total of 1298 patients were included in this retrospective analysis. Patients who underwent autologous cell-based cartilage treatment were significantly more likely to need revision cartilage restoration surgery compared with those who underwent osteochondral autograft treatment (11.1% vs 7.4%; OR, 1.58 [95% CI, 1.08-2.34]). There was no significant difference in the rate of progression to osteoarthritis (11.4% vs 10.6%; OR, 1.15; [95% CI, 0.80-1.65]) or subsequent knee arthroplasty (0.5% vs 1.1%; OR, 0.54 [95% CI, 0.11-2.06]) within 2 years of initial procedure between the treatment cohorts. Conclusion: This study highlights the increased risk of revision for patients who underwent autologous cell-based cartilage treatment compared with those who underwent osteochondral autograft treatment. However, no significant difference was identified in progression to osteoarthritis or subsequent knee arthroplasty within 2 years after the initial procedure. Further studies that evaluate long-term outcomes and the progression of symptoms are needed.
- 15 September 2025
- Published by SAGE Publications in Orthopaedic Journal of Sports Medicine
- Vol. 13 (9)
Open AccessCartilage Conundrum: Investigating Outcomes in Knee Cartilage Restoration Techniques
Background: Management of chondral injury can be difficult due to the avascularity of articular cartilage and the limited ability to proliferate and promote repair. Untreated lesions can lead to early development of arthritis and the need for joint replacement. For intermediate-sized lesions, osteochondral autograft transfer and autologous cell-based cartilage treatment have been accepted as the most effective treatment options. Purpose: To investigate the rates of complications within 2 years of initial surgery in patients who undergo primary autologous cell-based cartilage treatment and osteochondral autograft. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective cohort study was performed on July 17, 2024, using a commercially available insurance claims database to investigate 2-year orthopaedic complication rates in 1298 patients after primary osteochondral autograft and autologous cell-based cartilage treatment for chondral injuries of the knee. Patient cohorts were propensity score matched with a caliper set to 0.2 at a ratio of 1 to 1 on the following variables: age, sex, diabetes, and tobacco use. Rates of surgical complications were compared using multivariable logistic regression, adjusted for age, sex, diabetes, obesity, and tobacco use. Odds ratios (ORs) with corresponding 95% CIs were calculated for each comparison. Results: A total of 1298 patients were included in this retrospective analysis. Patients who underwent autologous cell-based cartilage treatment were significantly more likely to need revision cartilage restoration surgery compared with those who underwent osteochondral autograft treatment (11.1% vs 7.4%; OR, 1.58 [95% CI, 1.08-2.34]). There was no significant difference in the rate of progression to osteoarthritis (11.4% vs 10.6%; OR, 1.15; [95% CI, 0.80-1.65]) or subsequent knee arthroplasty (0.5% vs 1.1%; OR, 0.54 [95% CI, 0.11-2.06]) within 2 years of initial procedure between the treatment cohorts. Conclusion: This study highlights the increased risk of revision for patients who underwent autologous cell-based cartilage treatment compared with those who underwent osteochondral autograft treatment. However, no significant difference was identified in progression to osteoarthritis or subsequent knee arthroplasty within 2 years after the initial procedure. Further studies that evaluate long-term outcomes and the progression of symptoms are needed.
- Open Access
- 11 September 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 36 (1) , 151493
Reoperation roulette: unveiling diagnosis-specific complication rates in anatomic and reverse total shoulder arthroplasty
- 11 September 2025
- Published by Elsevier in Seminars in Arthroplasty: JSES
- Vol. 36 (1) , 151493
Open AccessReoperation roulette: unveiling diagnosis-specific complication rates in anatomic and reverse total shoulder arthroplasty
- Open Access
- 1 September 2025
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (9)
Ancient Principles, Modern Impact: Increased Femoral Offset Demonstrates Decreased Load to Failure in Total Hip Arthroplasty
Background: A critical decision in total hip arthroplasty implant selection is the choice of femoral offset. Femoral offset lateralizes the femoral shaft, tensioning the abductor mechanism providing stability and reducing joint reactive forces. Variations in offset may affect hip biomechanics, potentially influencing the risk of periprosthetic fractures. This study aimed to evaluate the forces required for implant failure and fracture in two femoral stems with different neck angles. Methods: Twenty osteoporotic composite femurs were prepared and implanted with either a Stryker Accolade II stem with 132° (standard offset) or 127° neck angle (high offset). Femurs were subjected to an axial load using a biaxial servohydroaulic testing machine until failure. Maximum load to failure was recorded. Finite element analysis was conducted to assess stress and strain distributions with the femurs for both implant types. Results: Femurs with a 132° neck angle exhibited significantly higher mean load to failure compared with those with a 127° neck angle (3,537.8 ± 627.9 vs. 2,947.6 ± 507.6 N, P = 0.032). Finite element analysis revealed that maximum stress in femurs with a high offset implant was 9.5% higher than the standard offset (135.9 vs. 124.1 N/m2) and maximum strain was 25.1% higher in the high offset stem compared with the standard offset (1.580e−8 vs. 1.263e−8). Conclusion: Higher femoral stem offset decreases the ultimate load to failure of the femur. Although high offset stems offer benefits in hip stability and abductor lever arm enhancement, their potential to increase fracture risk must be further explored.
- 1 September 2025
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 9 (9)
Open AccessAncient Principles, Modern Impact: Increased Femoral Offset Demonstrates Decreased Load to Failure in Total Hip Arthroplasty
Background: A critical decision in total hip arthroplasty implant selection is the choice of femoral offset. Femoral offset lateralizes the femoral shaft, tensioning the abductor mechanism providing stability and reducing joint reactive forces. Variations in offset may affect hip biomechanics, potentially influencing the risk of periprosthetic fractures. This study aimed to evaluate the forces required for implant failure and fracture in two femoral stems with different neck angles. Methods: Twenty osteoporotic composite femurs were prepared and implanted with either a Stryker Accolade II stem with 132° (standard offset) or 127° neck angle (high offset). Femurs were subjected to an axial load using a biaxial servohydroaulic testing machine until failure. Maximum load to failure was recorded. Finite element analysis was conducted to assess stress and strain distributions with the femurs for both implant types. Results: Femurs with a 132° neck angle exhibited significantly higher mean load to failure compared with those with a 127° neck angle (3,537.8 ± 627.9 vs. 2,947.6 ± 507.6 N, P = 0.032). Finite element analysis revealed that maximum stress in femurs with a high offset implant was 9.5% higher than the standard offset (135.9 vs. 124.1 N/m2) and maximum strain was 25.1% higher in the high offset stem compared with the standard offset (1.580e−8 vs. 1.263e−8). Conclusion: Higher femoral stem offset decreases the ultimate load to failure of the femur. Although high offset stems offer benefits in hip stability and abductor lever arm enhancement, their potential to increase fracture risk must be further explored.
- Open Access
- 15 May 2025
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 7 (4) , 101164
Arthroscopic Repair of Distal Triceps Tendon Rupture Provides Excellent Functional Outcomes With Minimal Complications
Purpose: To report the outcomes of patients who underwent arthroscopic distal triceps tendon repair using double‐row anatomic footprint repair with suture anchors. Methods: This was a retrospective review of patients who underwent arthroscopic triceps tendon repair between 2012 and 2022 performed by a single surgeon. The inclusion criteria included a full‐thickness tear of the distal triceps tendon confirmed by magnetic resonance imaging and repaired arthroscopically. The exclusion criteria included patients with documented follow‐up of less than 24 months for whom postoperative outcome measures were lacking, as well as tear size of less than 50% of the width of the tendon. The primary outcome measures were retear rates and reoperation rates. Secondary outcomes included change in pain score (visual analog scale), postoperative functional score (Mayo Elbow Performance Score), postoperative Single Assessment Numeric Evaluation score, manual muscle testing, and rate of perioperative wound complications. Results: A total of 16 patients (age range, 37‐80 years) were included. All patients had an intact triceps tendon on ultrasound at a mean follow‐up of 79.3 months (range, 24.6‐149.1 months). The mean preoperative visual analog scale pain score decreased from 4 to 0, ranging from 0 to 6 preoperatively ( P < .001). The postoperative Mayo Elbow Performance Score averaged 100, indicating no functional limitations. The mean Single Assessment Numeric Evaluation score were 98, ranging from 90 to 100. No major perioperative wound complications, retears, or reoperations were reported. Muscle strength was graded as equal to the opposite side on manual strength testing. Conclusions: In this study, we found that arthroscopic triceps tendon repair is safe and effective, with excellent pain relief, excellent functional scores, minimal complications, and the ability to address concomitant elbow pathologies. Level of Evidence: Level IV, therapeutic case series.
- 15 May 2025
- Published by Wiley in Arthroscopy, Sports Medicine, and Rehabilitation
- Vol. 7 (4) , 101164
Open AccessArthroscopic Repair of Distal Triceps Tendon Rupture Provides Excellent Functional Outcomes With Minimal Complications
Purpose: To report the outcomes of patients who underwent arthroscopic distal triceps tendon repair using double‐row anatomic footprint repair with suture anchors. Methods: This was a retrospective review of patients who underwent arthroscopic triceps tendon repair between 2012 and 2022 performed by a single surgeon. The inclusion criteria included a full‐thickness tear of the distal triceps tendon confirmed by magnetic resonance imaging and repaired arthroscopically. The exclusion criteria included patients with documented follow‐up of less than 24 months for whom postoperative outcome measures were lacking, as well as tear size of less than 50% of the width of the tendon. The primary outcome measures were retear rates and reoperation rates. Secondary outcomes included change in pain score (visual analog scale), postoperative functional score (Mayo Elbow Performance Score), postoperative Single Assessment Numeric Evaluation score, manual muscle testing, and rate of perioperative wound complications. Results: A total of 16 patients (age range, 37‐80 years) were included. All patients had an intact triceps tendon on ultrasound at a mean follow‐up of 79.3 months (range, 24.6‐149.1 months). The mean preoperative visual analog scale pain score decreased from 4 to 0, ranging from 0 to 6 preoperatively ( P < .001). The postoperative Mayo Elbow Performance Score averaged 100, indicating no functional limitations. The mean Single Assessment Numeric Evaluation score were 98, ranging from 90 to 100. No major perioperative wound complications, retears, or reoperations were reported. Muscle strength was graded as equal to the opposite side on manual strength testing. Conclusions: In this study, we found that arthroscopic triceps tendon repair is safe and effective, with excellent pain relief, excellent functional scores, minimal complications, and the ability to address concomitant elbow pathologies. Level of Evidence: Level IV, therapeutic case series.
- 10 May 2025
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 64 (5) , 624-628
Are we putting our best foot forward? The effect of insurance type on ankle fracture complications and delays in care: a retrospective two-year analysis
- 10 May 2025
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 64 (5) , 624-628
Are we putting our best foot forward? The effect of insurance type on ankle fracture complications and delays in care: a retrospective two-year analysis
- Open Access
- 22 November 2024
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 59, 102839
Takeout or delivery? Reoperation rates in lower extremity long bone osteomyelitis treated with debridement and local antibiotic delivery systems
- 22 November 2024
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 59, 102839
Open AccessTakeout or delivery? Reoperation rates in lower extremity long bone osteomyelitis treated with debridement and local antibiotic delivery systems