Jie Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jie Ma has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Helei Dong
Key Laboratory of Micro/Nano Devices and Systems, Ministry of Education, North University of China, Taiyuan, China
4 shared publications Qiulin Tan
3 shared publicationsYu Wang
3 shared publicationsYuxin Miao
2 shared publications- Yuxin Miao
State Key Laboratory of Dynamic Measurement Technology, the Key Laboratory of Micro/Nano Devices and Systems, Ministry of Education, and the Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan, China
2 shared publications Zhen Jia
2 shared publications
Latest Publications
- 4 April 2025
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 45 (12)
Enhanced high temperature thermal stability of In2O3-IHFO thin film thermocouples using composite protective layers
- 4 April 2025
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 45 (12)
Enhanced high temperature thermal stability of In2O3-IHFO thin film thermocouples using composite protective layers
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Dynamic Response Testing Based on Pulsed Laser and WOA-BP Neural Network
Laser heating has become a common means of dynamic response testing, but accurate measurement of the dynamic response time poses a challenge, mainly due to the interference from the thermophysical parameters of K-type thin film thermocouple, temperature measurement environments, and stray signals. To address this issue, this paper designs a dynamic response testing platform for thermocouples based on lasers and constructs a WOA-BP algorithm model. This model aims to accurately predict the dynamic response time and output peak voltage of the thermocouple, providing guidance for parameter optimization during the experimental process and ensuring efficient capture of the thermocouple’s dynamic response signals. Meanwhile, this paper compared the WOA-BP algorithmic model with BP and other optimized BP models, evaluated by RMSE, MAE and R2. The results demonstrate that with the guidance of parameter optimization by the WOA-BP algorithm model, the dynamic testing system is capable of accurately performing dynamic performance tests on thermocouples. Besides, the dynamic response time is inversely proportional to laser power and directly proportional to laser pulse width, but independent of repetition frequency. The output peak voltage increases with the increase of laser power and pulse width, but is also independent of laser repetition frequency. And the WOA-BP algorithm model can predict dynamic response time and output peak voltage accurately, whose R2 values of dynamic response time and output peak voltage are 0.9954 and 0.9982, the RMSE values are 0.5766 and 0.2981, and the MAE values are 0.4152 and 0.2700, respectively, being the best compared with BP, PSO-BP, GA-BP, MFO-BP and GWO-BP prediction models.
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-12
Dynamic Response Testing Based on Pulsed Laser and WOA-BP Neural Network
Laser heating has become a common means of dynamic response testing, but accurate measurement of the dynamic response time poses a challenge, mainly due to the interference from the thermophysical parameters of K-type thin film thermocouple, temperature measurement environments, and stray signals. To address this issue, this paper designs a dynamic response testing platform for thermocouples based on lasers and constructs a WOA-BP algorithm model. This model aims to accurately predict the dynamic response time and output peak voltage of the thermocouple, providing guidance for parameter optimization during the experimental process and ensuring efficient capture of the thermocouple’s dynamic response signals. Meanwhile, this paper compared the WOA-BP algorithmic model with BP and other optimized BP models, evaluated by RMSE, MAE and R2. The results demonstrate that with the guidance of parameter optimization by the WOA-BP algorithm model, the dynamic testing system is capable of accurately performing dynamic performance tests on thermocouples. Besides, the dynamic response time is inversely proportional to laser power and directly proportional to laser pulse width, but independent of repetition frequency. The output peak voltage increases with the increase of laser power and pulse width, but is also independent of laser repetition frequency. And the WOA-BP algorithm model can predict dynamic response time and output peak voltage accurately, whose R2 values of dynamic response time and output peak voltage are 0.9954 and 0.9982, the RMSE values are 0.5766 and 0.2981, and the MAE values are 0.4152 and 0.2700, respectively, being the best compared with BP, PSO-BP, GA-BP, MFO-BP and GWO-BP prediction models.
- 22 November 2024
- Published by Elsevier in Ceramics International
- Vol. 51 (3) , 3693-3702
Fully printed direct-write preparation of high-temperature-resistant thermocouple sensors and their performance
- 22 November 2024
- Published by Elsevier in Ceramics International
- Vol. 51 (3) , 3693-3702
Fully printed direct-write preparation of high-temperature-resistant thermocouple sensors and their performance