Ruipeng Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ruipeng Zhang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Zhiyong Hou
Department of Orthopedic Surgery, Hebei Medical University Third Hospital
23 shared publications - Yingchao Yin
Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, China
19 shared publications - Yingze Zhang
Nankai University, Tianjin, China
19 shared publications Shilun Li
A Department of Orthopaedic Surgery , Third Hospital of Hebei Medical University , Shijiazhuang , Hebei, China
9 shared publicationsLin Jin
Department of Orthopaedic Surgery, The Third Hospital of Hebei Medical University
5 shared publicationsWei Chen
Department of Orthopaedic Surgery, Third Hospital of Hebei Medical University, Shijiazhuang, 050051, Hebei, China
4 shared publications
Latest Publications
- Open Access
- 2 July 2026
- Published by JMIR Publications Inc. in JMIR Medical Education
- Vol. 12, e98949
Artificial Intelligence for Assessment and Feedback in Medical Education: Bibliometric Mapping Study and Thematic Evidence Map
Background: Artificial intelligence (AI), particularly generative AI and large language models, is increasingly used for assessment-related tasks in medical education. Existing overviews often address AI in medical education broadly, limiting assessment-specific interpretation of functions, settings, learner stages, and responsible-AI reporting domains. Objective: This study aims to map the literature on AI for assessment and feedback in medical education, including publication trends, bibliometric structure, assessment functions, AI types, settings, learner stages, and reporting of validity, reliability, fairness, integrity, transparency, human oversight, implementation, and governance. Methods: We conducted a bibliometric mapping study incorporating structured thematic evidence-map coding. Web of Science Core Collection, Scopus, and PubMed were searched from January 1, 2015, to April 8, 2026. Document selection and main evidence-map coding were based primarily on titles, abstracts, and bibliographic metadata, with targeted ambiguity resolution. Because reporting domains may appear mainly in full-text sections, all 435 included records underwent full-text sensitivity analysis for the 8 reporting domains. Coding reliability was assessed by two coders using percent agreement and Cohen κ before adjudication. Exploratory subgroup analyses and an excluding-2026 partial-year sensitivity analysis were conducted. Results: Searches identified 14,968 records; 435 were included after deduplication and selection. Overall, 399 (91.7%) records were indexed in the post-ChatGPT period. Generative AI was coded in 310 (71.3%) records, and large language models in 301 (69.2%) records. In the assessment-function umbrella analysis, learner performance evaluation accounted for 270 (62.1%) records, feedback for 93 (21.4%) records, assessment content generation for 65 (14.9%) records, and other or unclear functions for 7 (1.6%) records. The most common settings were board-style examinations (n=151, 34.7%) and written examinations (n=88, 20.2%); undergraduate medical education was the most represented learner stage (n=172, 39.5%). Full-text–confirmed reporting was most frequent for reliability (n=288, 66.2%) and implementation (n=231, 53.1%); intermediate for validity (n=158, 36.3%), fairness (n=132, 30.3%), and transparency (n=130, 29.9%); and less frequent for governance (n=57, 13.1%), human oversight (n=46, 10.6%), and integrity (n=26, 6%). Stage 1 κ values ranged from 0.785 to 0.895, and stage 2 κ values ranged from 0.809 to 0.880. Excluding 65 partial-year 2026 records did not change the overall interpretation. Conclusions: The indexed English-language literature on AI for assessment and feedback in medical education expanded rapidly in the post-ChatGPT period and was concentrated in generative AI, large language models, examination-oriented assessment, and undergraduate medical education. Future studies should complement examination benchmarking with authentic assessment contexts, distinguish assessment content generation from learner-facing evaluation and feedback, and report responsible assessment domains more consistently.
- 2 July 2026
- Published by JMIR Publications Inc. in JMIR Medical Education
- Vol. 12, e98949
Open AccessArtificial Intelligence for Assessment and Feedback in Medical Education: Bibliometric Mapping Study and Thematic Evidence Map
Background: Artificial intelligence (AI), particularly generative AI and large language models, is increasingly used for assessment-related tasks in medical education. Existing overviews often address AI in medical education broadly, limiting assessment-specific interpretation of functions, settings, learner stages, and responsible-AI reporting domains. Objective: This study aims to map the literature on AI for assessment and feedback in medical education, including publication trends, bibliometric structure, assessment functions, AI types, settings, learner stages, and reporting of validity, reliability, fairness, integrity, transparency, human oversight, implementation, and governance. Methods: We conducted a bibliometric mapping study incorporating structured thematic evidence-map coding. Web of Science Core Collection, Scopus, and PubMed were searched from January 1, 2015, to April 8, 2026. Document selection and main evidence-map coding were based primarily on titles, abstracts, and bibliographic metadata, with targeted ambiguity resolution. Because reporting domains may appear mainly in full-text sections, all 435 included records underwent full-text sensitivity analysis for the 8 reporting domains. Coding reliability was assessed by two coders using percent agreement and Cohen κ before adjudication. Exploratory subgroup analyses and an excluding-2026 partial-year sensitivity analysis were conducted. Results: Searches identified 14,968 records; 435 were included after deduplication and selection. Overall, 399 (91.7%) records were indexed in the post-ChatGPT period. Generative AI was coded in 310 (71.3%) records, and large language models in 301 (69.2%) records. In the assessment-function umbrella analysis, learner performance evaluation accounted for 270 (62.1%) records, feedback for 93 (21.4%) records, assessment content generation for 65 (14.9%) records, and other or unclear functions for 7 (1.6%) records. The most common settings were board-style examinations (n=151, 34.7%) and written examinations (n=88, 20.2%); undergraduate medical education was the most represented learner stage (n=172, 39.5%). Full-text–confirmed reporting was most frequent for reliability (n=288, 66.2%) and implementation (n=231, 53.1%); intermediate for validity (n=158, 36.3%), fairness (n=132, 30.3%), and transparency (n=130, 29.9%); and less frequent for governance (n=57, 13.1%), human oversight (n=46, 10.6%), and integrity (n=26, 6%). Stage 1 κ values ranged from 0.785 to 0.895, and stage 2 κ values ranged from 0.809 to 0.880. Excluding 65 partial-year 2026 records did not change the overall interpretation. Conclusions: The indexed English-language literature on AI for assessment and feedback in medical education expanded rapidly in the post-ChatGPT period and was concentrated in generative AI, large language models, examination-oriented assessment, and undergraduate medical education. Future studies should complement examination benchmarking with authentic assessment contexts, distinguish assessment content generation from learner-facing evaluation and feedback, and report responsible assessment domains more consistently.
- Open Access
- 21 April 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Artificial Intelligence for Assessment and Feedback in Medical Education: Bibliometric Mapping Study and Thematic Evidence Map (Preprint)
BACKGROUND Artificial intelligence (AI), particularly generative AI and large language models, is increasingly used for assessment-related tasks in medical education. Existing overviews often address AI in medical education broadly, limiting assessment-specific interpretation of functions, settings, learner stages, and responsible-AI reporting domains. OBJECTIVE This study aims to map the literature on AI for assessment and feedback in medical education, including publication trends, bibliometric structure, assessment functions, AI types, settings, learner stages, and reporting of validity, reliability, fairness, integrity, transparency, human oversight, implementation, and governance. METHODS We conducted a bibliometric mapping study incorporating structured thematic evidence-map coding. Web of Science Core Collection, Scopus, and PubMed were searched from January 1, 2015, to April 8, 2026. Document selection and main evidence-map coding were based primarily on titles, abstracts, and bibliographic metadata, with targeted ambiguity resolution. Because reporting domains may appear mainly in full-text sections, all 435 included records underwent full-text sensitivity analysis for the 8 reporting domains. Coding reliability was assessed by two coders using percent agreement and Cohen κ before adjudication. Exploratory subgroup analyses and an excluding-2026 partial-year sensitivity analysis were conducted. RESULTS Searches identified 14,968 records; 435 were included after deduplication and selection. Overall, 399 (91.7%) records were indexed in the post-ChatGPT period. Generative AI was coded in 310 (71.3%) records, and large language models in 301 (69.2%) records. In the assessment-function umbrella analysis, learner performance evaluation accounted for 270 (62.1%) records, feedback for 93 (21.4%) records, assessment content generation for 65 (14.9%) records, and other or unclear functions for 7 (1.6%) records. The most common settings were board-style examinations (n=151, 34.7%) and written examinations (n=88, 20.2%); undergraduate medical education was the most represented learner stage (n=172, 39.5%). Full-text–confirmed reporting was most frequent for reliability (n=288, 66.2%) and implementation (n=231, 53.1%); intermediate for validity (n=158, 36.3%), fairness (n=132, 30.3%), and transparency (n=130, 29.9%); and less frequent for governance (n=57, 13.1%), human oversight (n=46, 10.6%), and integrity (n=26, 6%). Stage 1 κ values ranged from 0.785 to 0.895, and stage 2 κ values ranged from 0.809 to 0.880. Excluding 65 partial-year 2026 records did not change the overall interpretation. CONCLUSIONS The indexed English-language literature on AI for assessment and feedback in medical education expanded rapidly in the post-ChatGPT period and was concentrated in generative AI, large language models, examination-oriented assessment, and undergraduate medical education. Future studies should complement examination benchmarking with authentic assessment contexts, distinguish assessment content generation from learner-facing evaluation and feedback, and report responsible assessment domains more consistently.
- 21 April 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessArtificial Intelligence for Assessment and Feedback in Medical Education: Bibliometric Mapping Study and Thematic Evidence Map (Preprint)
BACKGROUND Artificial intelligence (AI), particularly generative AI and large language models, is increasingly used for assessment-related tasks in medical education. Existing overviews often address AI in medical education broadly, limiting assessment-specific interpretation of functions, settings, learner stages, and responsible-AI reporting domains. OBJECTIVE This study aims to map the literature on AI for assessment and feedback in medical education, including publication trends, bibliometric structure, assessment functions, AI types, settings, learner stages, and reporting of validity, reliability, fairness, integrity, transparency, human oversight, implementation, and governance. METHODS We conducted a bibliometric mapping study incorporating structured thematic evidence-map coding. Web of Science Core Collection, Scopus, and PubMed were searched from January 1, 2015, to April 8, 2026. Document selection and main evidence-map coding were based primarily on titles, abstracts, and bibliographic metadata, with targeted ambiguity resolution. Because reporting domains may appear mainly in full-text sections, all 435 included records underwent full-text sensitivity analysis for the 8 reporting domains. Coding reliability was assessed by two coders using percent agreement and Cohen κ before adjudication. Exploratory subgroup analyses and an excluding-2026 partial-year sensitivity analysis were conducted. RESULTS Searches identified 14,968 records; 435 were included after deduplication and selection. Overall, 399 (91.7%) records were indexed in the post-ChatGPT period. Generative AI was coded in 310 (71.3%) records, and large language models in 301 (69.2%) records. In the assessment-function umbrella analysis, learner performance evaluation accounted for 270 (62.1%) records, feedback for 93 (21.4%) records, assessment content generation for 65 (14.9%) records, and other or unclear functions for 7 (1.6%) records. The most common settings were board-style examinations (n=151, 34.7%) and written examinations (n=88, 20.2%); undergraduate medical education was the most represented learner stage (n=172, 39.5%). Full-text–confirmed reporting was most frequent for reliability (n=288, 66.2%) and implementation (n=231, 53.1%); intermediate for validity (n=158, 36.3%), fairness (n=132, 30.3%), and transparency (n=130, 29.9%); and less frequent for governance (n=57, 13.1%), human oversight (n=46, 10.6%), and integrity (n=26, 6%). Stage 1 κ values ranged from 0.785 to 0.895, and stage 2 κ values ranged from 0.809 to 0.880. Excluding 65 partial-year 2026 records did not change the overall interpretation. CONCLUSIONS The indexed English-language literature on AI for assessment and feedback in medical education expanded rapidly in the post-ChatGPT period and was concentrated in generative AI, large language models, examination-oriented assessment, and undergraduate medical education. Future studies should complement examination benchmarking with authentic assessment contexts, distinguish assessment content generation from learner-facing evaluation and feedback, and report responsible assessment domains more consistently.
- Open Access
- 15 December 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (12) , e0339026
Comparison of outcomes between minimally invasive percutaneous bunnell suture and traditional open modified Kessler technique for acute closed achilles tendon rupture: A single-center cohort study
Percutaneous Bunnell repair and open modified Kessler repair remain debated options for acute Achilles tendon rupture (AATR). We retrospectively compared a minimally invasive percutaneous Bunnell technique (Group A) with an open modified Kessler repair (Group B) within a standardized early functional rehabilitation (EFR) protocol at a single center. Fifty-five adults with closed AATR treated between January 2021 and December 2022 were analyzed (Group A, n = 25; Group B, n = 30). Between-group comparisons used Welch t tests for continuous variables and χ² or Fisher exact tests for categorical variables; American Orthopaedic Foot & Ankle Society (AOFAS) and Achilles Tendon Total Rupture Score (ATRS) were assessed at 12 and 24 weeks, with Holm adjustment applied within each scale. Compared with Group B, Group A had shorter operative time (56.6 ± 15.1 vs 68.2 ± 23.2 minutes; mean difference −11.6; 95% CI −22.05 to −1.15; P = 0.030), less intraoperative blood loss (28.4 ± 8.4 vs 74.7 ± 19.4 mL; −46.3; 95% CI −54.22 to −38.38; P < 0.001), and a shorter length of stay (4.8 ± 2.0 vs 6.6 ± 2.9 days; −1.8; 95% CI −3.13 to −0.47; P = 0.009). At 12 weeks, AOFAS favored Group A (+1.36; 95% CI + 0.19 to +2.53; P = 0.047) and ATRS also favored Group A (+1.73; 95% CI + 0.48 to +2.98; P = 0.008). At 24 weeks, AOFAS was not different (+0.51; 95% CI −0.49 to +1.51; P = 0.312), whereas ATRS remained higher in Group A (+2.17; 95% CI + 0.88 to +3.46; P = 0.003). Overall complications were 12.0% vs 26.7% (risk difference −14.7%; 95% CI −34.10 to +7.20; P = 0.310); no sural nerve injuries occurred. Within an EFR framework, percutaneous Bunnell repair provided superior perioperative efficiency with comparable safety and modest, sub-MCID functional advantages, supporting confirmation in larger prospective studies.
- 15 December 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (12) , e0339026
Open AccessComparison of outcomes between minimally invasive percutaneous bunnell suture and traditional open modified Kessler technique for acute closed achilles tendon rupture: A single-center cohort study
Percutaneous Bunnell repair and open modified Kessler repair remain debated options for acute Achilles tendon rupture (AATR). We retrospectively compared a minimally invasive percutaneous Bunnell technique (Group A) with an open modified Kessler repair (Group B) within a standardized early functional rehabilitation (EFR) protocol at a single center. Fifty-five adults with closed AATR treated between January 2021 and December 2022 were analyzed (Group A, n = 25; Group B, n = 30). Between-group comparisons used Welch t tests for continuous variables and χ² or Fisher exact tests for categorical variables; American Orthopaedic Foot & Ankle Society (AOFAS) and Achilles Tendon Total Rupture Score (ATRS) were assessed at 12 and 24 weeks, with Holm adjustment applied within each scale. Compared with Group B, Group A had shorter operative time (56.6 ± 15.1 vs 68.2 ± 23.2 minutes; mean difference −11.6; 95% CI −22.05 to −1.15; P = 0.030), less intraoperative blood loss (28.4 ± 8.4 vs 74.7 ± 19.4 mL; −46.3; 95% CI −54.22 to −38.38; P < 0.001), and a shorter length of stay (4.8 ± 2.0 vs 6.6 ± 2.9 days; −1.8; 95% CI −3.13 to −0.47; P = 0.009). At 12 weeks, AOFAS favored Group A (+1.36; 95% CI + 0.19 to +2.53; P = 0.047) and ATRS also favored Group A (+1.73; 95% CI + 0.48 to +2.98; P = 0.008). At 24 weeks, AOFAS was not different (+0.51; 95% CI −0.49 to +1.51; P = 0.312), whereas ATRS remained higher in Group A (+2.17; 95% CI + 0.88 to +3.46; P = 0.003). Overall complications were 12.0% vs 26.7% (risk difference −14.7%; 95% CI −34.10 to +7.20; P = 0.310); no sural nerve injuries occurred. Within an EFR framework, percutaneous Bunnell repair provided superior perioperative efficiency with comparable safety and modest, sub-MCID functional advantages, supporting confirmation in larger prospective studies.
- 25 September 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (6) , 621-627
Simplifying the Orientation of S1 Iliosacral Screws for Placement in the Dysmorphic Sacrum
Background: Determining the proper iliosacral screw orientation in a dysmorphic S1 sacral segment using a C-arm is difficult, and pelvic computed tomography (CT) is often necessary for the preoperative planning. On the preoperative pelvic axial CT section, the intended screw trajectory can be delineated intraosseously along the axis of the oblique osseous corridor. An inherently accurate orientation would be determined by 2 factors: (1) the trajectory is in the pelvic transverse plane, and (2) it is oriented relative to the coronal plane at a patient-specific angle, which should be measured preoperatively. Based on the above reasoning, we aimed to simplify and verify the orientation. Methods: After establishing the starting point on the sacral lateral view, we tested a method of simplifying the guidewire orientation: placing the guidewire in the pelvic transverse plane and then manipulating it to be angled relative to the coronal plane at the preoperatively measured patient-specific angle. The guidewire orientation should then be reproducibly accurate on the pelvic outlet and inlet views. The feasibility and safety of our method were verified through computer-simulated virtual surgical procedures in 95 dysmorphic sacra and clinical surgical procedures in 12 patients. The primary outcome parameters were the guidewire orientation and screw placement accuracy. Results: Using our method, the S1 guidewire orientation was reproducibly accurate on the pelvic outlet and inlet views in all of the virtual and clinical surgical procedures. Ninety-five virtual S1 screws (1 screw in each left hemipelvis) were placed intraosseously in the pelvic transverse plane. Fourteen unilateral S1 screws were placed intraosseously in the pelvic transverse plane in the 12 patients (2 patients had double screws) without iatrogenic injuries. Conclusions: The guidewire orientation can be simplified by placing the guidewire in the pelvic transverse plane and replicating the preoperatively measured patient-specific angle between the guidewire and the coronal plane. After establishing the starting point on the sacral lateral view, our simplified manipulation yields a reproducibly accurate orientation on the pelvic outlet and inlet views. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 25 September 2024
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (6) , 621-627
Simplifying the Orientation of S1 Iliosacral Screws for Placement in the Dysmorphic Sacrum
Background: Determining the proper iliosacral screw orientation in a dysmorphic S1 sacral segment using a C-arm is difficult, and pelvic computed tomography (CT) is often necessary for the preoperative planning. On the preoperative pelvic axial CT section, the intended screw trajectory can be delineated intraosseously along the axis of the oblique osseous corridor. An inherently accurate orientation would be determined by 2 factors: (1) the trajectory is in the pelvic transverse plane, and (2) it is oriented relative to the coronal plane at a patient-specific angle, which should be measured preoperatively. Based on the above reasoning, we aimed to simplify and verify the orientation. Methods: After establishing the starting point on the sacral lateral view, we tested a method of simplifying the guidewire orientation: placing the guidewire in the pelvic transverse plane and then manipulating it to be angled relative to the coronal plane at the preoperatively measured patient-specific angle. The guidewire orientation should then be reproducibly accurate on the pelvic outlet and inlet views. The feasibility and safety of our method were verified through computer-simulated virtual surgical procedures in 95 dysmorphic sacra and clinical surgical procedures in 12 patients. The primary outcome parameters were the guidewire orientation and screw placement accuracy. Results: Using our method, the S1 guidewire orientation was reproducibly accurate on the pelvic outlet and inlet views in all of the virtual and clinical surgical procedures. Ninety-five virtual S1 screws (1 screw in each left hemipelvis) were placed intraosseously in the pelvic transverse plane. Fourteen unilateral S1 screws were placed intraosseously in the pelvic transverse plane in the 12 patients (2 patients had double screws) without iatrogenic injuries. Conclusions: The guidewire orientation can be simplified by placing the guidewire in the pelvic transverse plane and replicating the preoperatively measured patient-specific angle between the guidewire and the coronal plane. After establishing the starting point on the sacral lateral view, our simplified manipulation yields a reproducibly accurate orientation on the pelvic outlet and inlet views. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 22 November 2023
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (2) , 129-137
Specifying the Starting Point for S1 Iliosacral Screw Placement in the Dysmorphic Sacrum
Background: Sacral dysmorphism is not uncommon and complicates S1 iliosacral screw placement partially because of the difficulty of determining the starting point accurately on the sacral lateral view. We propose a method of specifying the starting point. Methods: The starting point for the S1 iliosacral screw into the dysmorphic sacrum was specifically set at a point where the ossification of the S1/S2 intervertebral disc (OSID) intersected the posterior vertebral cortical line (PVCL) on the sacral lateral view, followed by guidewire manipulation and screw placement on the pelvic outlet and inlet views. Computer-simulated virtual surgical procedures based on pelvic computed tomography (CT) data on 95 dysmorphic sacra were performed to determine whether the starting point was below the iliac cortical density (ICD) and in the S1 oblique osseous corridor and to evaluate the accuracy of screw placement (with 1 screw being used, in the left hemipelvis). Surgical procedures on 17 patients were performed to verify the visibility of the OSID and PVCL, to check the location of the starting point relative to the ICD, and to validate the screw placement safety as demonstrated with postoperative CT scans. Results: In the virtual surgical procedures, the starting point was consistently below the ICD and in the oblique osseous corridor in all patients and all screws were Grade 1. In the clinical surgical procedures, the OSID and PVCL were consistently visible and the starting point was always below the ICD in all patients; overall, 21 S1 iliosacral screws were placed in these 17 patients without malpositioning or iatrogenic injury. Conclusions: On the lateral view of the dysmorphic sacrum, the OSID and PVCL are visible and intersect at a point that is consistently below the ICD and in the oblique osseous corridor, and thus they can be used to identify the starting point. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 22 November 2023
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 106 (2) , 129-137
Specifying the Starting Point for S1 Iliosacral Screw Placement in the Dysmorphic Sacrum
Background: Sacral dysmorphism is not uncommon and complicates S1 iliosacral screw placement partially because of the difficulty of determining the starting point accurately on the sacral lateral view. We propose a method of specifying the starting point. Methods: The starting point for the S1 iliosacral screw into the dysmorphic sacrum was specifically set at a point where the ossification of the S1/S2 intervertebral disc (OSID) intersected the posterior vertebral cortical line (PVCL) on the sacral lateral view, followed by guidewire manipulation and screw placement on the pelvic outlet and inlet views. Computer-simulated virtual surgical procedures based on pelvic computed tomography (CT) data on 95 dysmorphic sacra were performed to determine whether the starting point was below the iliac cortical density (ICD) and in the S1 oblique osseous corridor and to evaluate the accuracy of screw placement (with 1 screw being used, in the left hemipelvis). Surgical procedures on 17 patients were performed to verify the visibility of the OSID and PVCL, to check the location of the starting point relative to the ICD, and to validate the screw placement safety as demonstrated with postoperative CT scans. Results: In the virtual surgical procedures, the starting point was consistently below the ICD and in the oblique osseous corridor in all patients and all screws were Grade 1. In the clinical surgical procedures, the OSID and PVCL were consistently visible and the starting point was always below the ICD in all patients; overall, 21 S1 iliosacral screws were placed in these 17 patients without malpositioning or iatrogenic injury. Conclusions: On the lateral view of the dysmorphic sacrum, the OSID and PVCL are visible and intersect at a point that is consistently below the ICD and in the oblique osseous corridor, and thus they can be used to identify the starting point. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 9212895
Morphological Characteristics of the Posterior Wall Associated with Complex Acetabular Fractures: A Radiological Study Using 3D Software and Fracture Mapping Technique
Background. The aim of the study was to compare the morphological distinctions of the posterior wall (PW) in different complex acetabular fractures using 3D software and fracture mapping technique and ultimately to provide for improved clinical treatment. Methods. One hundred and fourteen patients with complex acetabular fracture associated with PW were recruited. All patients were divided into two groups according to the injury mechanism of the PW: Group A (both‐column and PW) and Group B (including posterior column and PW; T shape and PW; and transverse and PW). Fracture mapping was generated on the intra‐ and extrasurface of a standard template. The radiological parameters including spatial displacement, articular surface area, articular range, marginal impaction, and multifragments of the two groups were compared. Results. The spatial displacement, intra‐/extra‐articular surface area, and start and end point in Group A were 10.9 mm (IQR, 8.4‐15.2), 8.2 ± 2.6 cm2, 17.9 ± 5.3 cm2, 0.8° (IQR, ‐6.0‐16.2), and 107.5° (IQR, 97.2‐116.9), respectively. The results in Group B were 30.4 mm (IQR, 16.8‐48.7), 4.1 ± 2.0 cm2, 10.6 ± 4.4 cm2, 29.5° (IQR, 19.2‐38.0), and 117.5° (IQR, 98.2‐127.2), respectively. Marginal impaction was defined by Letournel et al. All the differences between two groups were significant (P < 0.05). The fracture map in Group A showed an “L”‐shaped pattern and a “cusp” on the ilium, and the PW was located at 1/5 to 1/4 of the posterosuperior part of the acetabulum. The fracture maps in Group B were scattered and lacked consistency, and the PWs were confined to 1/10 to 1/8 of the posterior acetabulum. Conclusions. Quantitative measurements and fracture mapping represented the differences in morphological characteristics of PWs associated with complex acetabular fractures.
- 1 January 2022
- Published by Wiley in BioMed Research International
- Vol. 2022 (1) , 9212895
Open AccessMorphological Characteristics of the Posterior Wall Associated with Complex Acetabular Fractures: A Radiological Study Using 3D Software and Fracture Mapping Technique
Background. The aim of the study was to compare the morphological distinctions of the posterior wall (PW) in different complex acetabular fractures using 3D software and fracture mapping technique and ultimately to provide for improved clinical treatment. Methods. One hundred and fourteen patients with complex acetabular fracture associated with PW were recruited. All patients were divided into two groups according to the injury mechanism of the PW: Group A (both‐column and PW) and Group B (including posterior column and PW; T shape and PW; and transverse and PW). Fracture mapping was generated on the intra‐ and extrasurface of a standard template. The radiological parameters including spatial displacement, articular surface area, articular range, marginal impaction, and multifragments of the two groups were compared. Results. The spatial displacement, intra‐/extra‐articular surface area, and start and end point in Group A were 10.9 mm (IQR, 8.4‐15.2), 8.2 ± 2.6 cm2, 17.9 ± 5.3 cm2, 0.8° (IQR, ‐6.0‐16.2), and 107.5° (IQR, 97.2‐116.9), respectively. The results in Group B were 30.4 mm (IQR, 16.8‐48.7), 4.1 ± 2.0 cm2, 10.6 ± 4.4 cm2, 29.5° (IQR, 19.2‐38.0), and 117.5° (IQR, 98.2‐127.2), respectively. Marginal impaction was defined by Letournel et al. All the differences between two groups were significant (P < 0.05). The fracture map in Group A showed an “L”‐shaped pattern and a “cusp” on the ilium, and the PW was located at 1/5 to 1/4 of the posterosuperior part of the acetabulum. The fracture maps in Group B were scattered and lacked consistency, and the PWs were confined to 1/10 to 1/8 of the posterior acetabulum. Conclusions. Quantitative measurements and fracture mapping represented the differences in morphological characteristics of PWs associated with complex acetabular fractures.
- 8 September 2020
- Published by Springer Nature in International Orthopaedics
- Vol. 44 (12) , 2769-2777
Neutrophil to lymphocyte ratio and fracture severity in young and middle-aged patients with tibial plateau fractures
Purpose The neutrophil-to-lymphocyte ratio (NLR) has recently been found to be closely associated with the severity of trauma. This study aimed to analyze the correlation between the imaging severity of isolated tibial plateau fractures (TPFs) and the NLR in the blood. Methods A total of 223 patients with isolated TPFs were enrolled in this retrospective study over five years. The data at hospital admission were extracted from an electronic database. Schatzker classification was performed according to the imaging data by two experienced orthopaedic surgeons. All patients were divided into two groups: group 1 included patients with mild-to-moderate fractures (Schatzker types I–IV), and group 2 included patients with severe fractures (Schatzker types V–VI). The NLR levels at hospital admission were statistically compared between the two groups. Results The blood NLR, hemoglobin level, red blood cell count, neutrophil count, platelet count, time from injury to admission, total protein, and Na+ levels were significantly different among the two groups. According to the receiver operating characteristic (ROC) curve, the cutoff for the NLR was 5.8. ROC curve analysis showed that the sensitivity of an NLR ≥ 5.8 to predict severe TPFs was 53.4%, and the specificity was 70.7%. In the multivariate analysis, NLR ≥ 5.8 and haemoglobin < lower limit appeared to be independent predictors of severe TPFs. Conclusions Our study is the first to demonstrate that the NLR level appears to be a useful biomarker for predicting the severity of isolated TPFs in young and middle-aged adults.
- 8 September 2020
- Published by Springer Nature in International Orthopaedics
- Vol. 44 (12) , 2769-2777
Neutrophil to lymphocyte ratio and fracture severity in young and middle-aged patients with tibial plateau fractures
Purpose The neutrophil-to-lymphocyte ratio (NLR) has recently been found to be closely associated with the severity of trauma. This study aimed to analyze the correlation between the imaging severity of isolated tibial plateau fractures (TPFs) and the NLR in the blood. Methods A total of 223 patients with isolated TPFs were enrolled in this retrospective study over five years. The data at hospital admission were extracted from an electronic database. Schatzker classification was performed according to the imaging data by two experienced orthopaedic surgeons. All patients were divided into two groups: group 1 included patients with mild-to-moderate fractures (Schatzker types I–IV), and group 2 included patients with severe fractures (Schatzker types V–VI). The NLR levels at hospital admission were statistically compared between the two groups. Results The blood NLR, hemoglobin level, red blood cell count, neutrophil count, platelet count, time from injury to admission, total protein, and Na+ levels were significantly different among the two groups. According to the receiver operating characteristic (ROC) curve, the cutoff for the NLR was 5.8. ROC curve analysis showed that the sensitivity of an NLR ≥ 5.8 to predict severe TPFs was 53.4%, and the specificity was 70.7%. In the multivariate analysis, NLR ≥ 5.8 and haemoglobin < lower limit appeared to be independent predictors of severe TPFs. Conclusions Our study is the first to demonstrate that the NLR level appears to be a useful biomarker for predicting the severity of isolated TPFs in young and middle-aged adults.
- Open Access
- 1 July 2019
- Published by Wolters Kluwer Health in Medicine
- Vol. 98 (27) , e16260
Acute compartment syndrome
Background: Acute compartment syndrome (ACS) is defined as a clinical entity originated from trauma or other conditions, and remains challenging to diagnose and treat effectively. The review was aim to present the controversy in diagnosing, treating ACS. It was found that there was no criterion about the ACS, and result unnecessary osteotomy. The presence of clinical assessment (5P) always means the necrosis of muscles and was the most serious or irreversible stage of ACS. Besides pressure methods, the threshold of pressure identifying ACS was also controversial. Methods: Immediate surgical fasciotomy was important to prevent severe suquelae of the ACS. However, there was still controversy about the right time that fasciotomy should be done to avoid irreversible ischemic changes. The most important thing to treat ACS was comprehension to the true injury mechanism, but a systemic classification about traumatic mechanism in most literature was not clear. Results: After observations to fracture patients with blister, we recommended that surgeons dealing with such emergencies should be vigilant, and the indication for fasciotomy should be strictly controlled following with injury mechanism especially for patients without severe soft tissue injury. Conclusion: For those crushing and soft tissue injuries, the current evidence based strategies for managing patients was useful, but for those fracture related injury, more examination was necessary to avoid overtreatment especially for those patients with blister observed. In facing patients, medical history, injured mechanism should be paid special attention, and rigorous classification about traumatic etiology was the key for the treatment of these patients.
- 1 July 2019
- Published by Wolters Kluwer Health in Medicine
- Vol. 98 (27) , e16260
Open AccessAcute compartment syndrome
Background: Acute compartment syndrome (ACS) is defined as a clinical entity originated from trauma or other conditions, and remains challenging to diagnose and treat effectively. The review was aim to present the controversy in diagnosing, treating ACS. It was found that there was no criterion about the ACS, and result unnecessary osteotomy. The presence of clinical assessment (5P) always means the necrosis of muscles and was the most serious or irreversible stage of ACS. Besides pressure methods, the threshold of pressure identifying ACS was also controversial. Methods: Immediate surgical fasciotomy was important to prevent severe suquelae of the ACS. However, there was still controversy about the right time that fasciotomy should be done to avoid irreversible ischemic changes. The most important thing to treat ACS was comprehension to the true injury mechanism, but a systemic classification about traumatic mechanism in most literature was not clear. Results: After observations to fracture patients with blister, we recommended that surgeons dealing with such emergencies should be vigilant, and the indication for fasciotomy should be strictly controlled following with injury mechanism especially for patients without severe soft tissue injury. Conclusion: For those crushing and soft tissue injuries, the current evidence based strategies for managing patients was useful, but for those fracture related injury, more examination was necessary to avoid overtreatment especially for those patients with blister observed. In facing patients, medical history, injured mechanism should be paid special attention, and rigorous classification about traumatic etiology was the key for the treatment of these patients.
- 20 March 2019
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 33 (7) , 684-686
Crescent Technique with Dual C-Shaped Reconstruction Plates for Posterior Acetabular Wall Fractures: An Invited Commentary
(2019). Crescent Technique with Dual C-Shaped Reconstruction Plates for Posterior Acetabular Wall Fractures: An Invited Commentary. Journal of Investigative Surgery. Ahead of Print.
- 20 March 2019
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 33 (7) , 684-686
Crescent Technique with Dual C-Shaped Reconstruction Plates for Posterior Acetabular Wall Fractures: An Invited Commentary
(2019). Crescent Technique with Dual C-Shaped Reconstruction Plates for Posterior Acetabular Wall Fractures: An Invited Commentary. Journal of Investigative Surgery. Ahead of Print.
- 19 March 2019
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 33 (8) , 784-792
Lumbopelvic Fixation Versus Novel Adjustable Plate for Sacral Fractures: A Retrospective Comparative Study
Purpose: The purpose of this study is to compare the therapeutic effects of the lumbopelvic technique and a novel adjustable plate for sacral fractures. Materials and Methods: Patients with unilateral sacral fractures fixed via the lumbopelvic technique or using a novel adjustable plate from June 2011 to June 2017 were recruited into this study and were divided into two groups: group A (lumbopelvic fixation) and group B (novel adjustable plate). Surgical time, intraoperative blood loss, frequency of intraoperative fluoroscopy, reduction quality, and related complications were reviewed. Fracture healing was assessed by the radiographs conducted at follow-up. Functional outcome was evaluated according to the Majeed score at the final follow-up. Results: The mean blood loss and frequency of intraoperative fluoroscopy in group B were reduced compared with group A (both P < 0.001). The mean surgical time was 122.22 ± 13.09 minutes in group A and 103.96 ± 24.80 minutes in group B (P = 0.007). All patients healed well in this study, and no difference in the fracture healing time was noted between the two groups (P = 0.685). Satisfactory rates of reduction quality and functional outcome did not differ (both P > 0.05) in this study. The complication rate was 22.22% (4/18) in group A and 4.16% (1/24) in group B (P = 0.191). Conclusion: For patients with unilateral sacral fractures, satisfactory radiographic appearance and functional outcome could be obtained by both the lumbopelvic technique and a novel adjustable plate. However, the novel adjustable plate represents a less invasive technique with lower radiograph exposure.
- 19 March 2019
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 33 (8) , 784-792
Lumbopelvic Fixation Versus Novel Adjustable Plate for Sacral Fractures: A Retrospective Comparative Study
Purpose: The purpose of this study is to compare the therapeutic effects of the lumbopelvic technique and a novel adjustable plate for sacral fractures. Materials and Methods: Patients with unilateral sacral fractures fixed via the lumbopelvic technique or using a novel adjustable plate from June 2011 to June 2017 were recruited into this study and were divided into two groups: group A (lumbopelvic fixation) and group B (novel adjustable plate). Surgical time, intraoperative blood loss, frequency of intraoperative fluoroscopy, reduction quality, and related complications were reviewed. Fracture healing was assessed by the radiographs conducted at follow-up. Functional outcome was evaluated according to the Majeed score at the final follow-up. Results: The mean blood loss and frequency of intraoperative fluoroscopy in group B were reduced compared with group A (both P < 0.001). The mean surgical time was 122.22 ± 13.09 minutes in group A and 103.96 ± 24.80 minutes in group B (P = 0.007). All patients healed well in this study, and no difference in the fracture healing time was noted between the two groups (P = 0.685). Satisfactory rates of reduction quality and functional outcome did not differ (both P > 0.05) in this study. The complication rate was 22.22% (4/18) in group A and 4.16% (1/24) in group B (P = 0.191). Conclusion: For patients with unilateral sacral fractures, satisfactory radiographic appearance and functional outcome could be obtained by both the lumbopelvic technique and a novel adjustable plate. However, the novel adjustable plate represents a less invasive technique with lower radiograph exposure.