Marcela Burguera
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Marcela Burguera has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
C. Rondón
IVAIQUIM (Venezuelan Andean Institute of Chemistry), Faculty of Sciences, University of Los Andes, P.O. Box 542, Mérida 5101-A, Venezuela
1 shared publicationCarlos Rondón
Faculty of Sciences, IVAIQUIM (Venezuelan, Andean Institute for Chemical Research), Los Andes University, P.O. Box 542,Mérida,Venezuela
1 shared publicationCarlos Róndon
IVAIQUIM (Venezuelan Andean Institute for Chemical Research), Faculty of Sciences, University of Los Andes, P.O. Box 542, Mérida, Venezuela
1 shared publicationJ.L Burguera
IVAIQUIM (Venezuelan Andean Institute for Chemical Research), Faculty of Sciences, Los Andes University, P.O. Box 542, Mérida 5101-A, Venezuela
1 shared publicationJ.L. Burguera
IVAIQUIM (Venezuelan Andean Institute of Chemistry), Faculty of Sciences, University of Los Andes, P.O. Box 542, Mérida 5101-A, Venezuela
1 shared publicationJean Louis Salager
FIRP, Faculty of Engineering, University of Los Andes, Mérida, Venezuela
1 shared publication
Latest Publications
- 1 October 2001
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 56 (10) , 1801-1829
Flow injection-electrothermal atomic absorption spectrometry configurations: recent developments and trends
- 1 October 2001
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 56 (10) , 1801-1829
Flow injection-electrothermal atomic absorption spectrometry configurations: recent developments and trends
- 13 August 2001
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (10) , 1190-1195
Determination of bismuth in biological tissues by electrothermal atomic absorption spectrometry using platinum and tartaric acid as chemical modifier
A method for the determination of bismuth in a variety of biological tissues (bovine liver and kidney, pig and human stomach, and human teeth and bone) by atomic absorption spectrometry with electrothermal atomization was developed and evaluated. Platinum (2 µg) was chosen from several potential chemical modifiers (Lu, Ni, Pd and Zr) as the most appropriate for the sensitive and reliable determination of bismuth in such samples. Addition of 10 µl of 4% (w/v) tartaric acid together with platinum improved the stabilizing efficiency of the modifier. The method included digestion of approximately 100 mg of the tissues in 1.0 ml concentrated nitric acid and 0.2 ml hydrogen peroxide 30% (w/v) under microwave radiation. The detection limits were found to be 1.80 µg l−1 and about 0.1 µg g−1 for aqueous standards and biological tissues, respectively, and the characteristic mass was 22 pg. The relative standard deviation varied from 3.5 to 0.8% for aqueous standards of 30 and 100 µg l−1, respectively, and from 1.4 to 4.8% for the pooled samples submitted to microwave heating. The results obtained for the determination of bismuth in Seronorm™ trace elements materials (whole blood and urine) with known added amounts of bismuth, together with good recoveries (ca. 98.7%) for added analyte to samples before and after digestion, demonstrate the applicability of the procedure to the analysis of real samples.
- 13 August 2001
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 16 (10) , 1190-1195
Determination of bismuth in biological tissues by electrothermal atomic absorption spectrometry using platinum and tartaric acid as chemical modifier
A method for the determination of bismuth in a variety of biological tissues (bovine liver and kidney, pig and human stomach, and human teeth and bone) by atomic absorption spectrometry with electrothermal atomization was developed and evaluated. Platinum (2 µg) was chosen from several potential chemical modifiers (Lu, Ni, Pd and Zr) as the most appropriate for the sensitive and reliable determination of bismuth in such samples. Addition of 10 µl of 4% (w/v) tartaric acid together with platinum improved the stabilizing efficiency of the modifier. The method included digestion of approximately 100 mg of the tissues in 1.0 ml concentrated nitric acid and 0.2 ml hydrogen peroxide 30% (w/v) under microwave radiation. The detection limits were found to be 1.80 µg l−1 and about 0.1 µg g−1 for aqueous standards and biological tissues, respectively, and the characteristic mass was 22 pg. The relative standard deviation varied from 3.5 to 0.8% for aqueous standards of 30 and 100 µg l−1, respectively, and from 1.4 to 4.8% for the pooled samples submitted to microwave heating. The results obtained for the determination of bismuth in Seronorm™ trace elements materials (whole blood and urine) with known added amounts of bismuth, together with good recoveries (ca. 98.7%) for added analyte to samples before and after digestion, demonstrate the applicability of the procedure to the analysis of real samples.
- 19 April 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 15 (5) , 549-555
On-line emulsification of lubricating oils in a flow-injection system for chromium determination by electrothermal atomic absorption spectrometry
A simple and quick procedure has been developed for the on-line preparation of a one phase emulsion in a flow injection (FI) system for chromium determination by electrothermal atomic absorption spectrometry (ETAAS) with Zeeman-effect background correction. The entire FI system was controlled by a computer, independent of the spectrometer. A 1-ml plug of sample solution was injected into the carrier stream of hexane and was subsequently mixed with streams of 3.8% (m/v) sodium chloride, 5.0% (v/v) sodium dodecylsulfate (SDS) and 5.0% (v/v) of sec-butanol. The flow rates of the carrier, sodium chloride, SDS and sec-butanol streams were 1.0, 0.5, 0.5 and 0.2 ml min−1, respectively. The sonication of the flowing solutions improved the stability of the emulsion and provided quantitative recoveries. An emulsified sub-sample of 200-µl was collected in a capillary of a sampling arm assembly. Thereafter, 20 µl of this sample solution were introduced by means of positive displacement with air through a time-based solenoid injector (TBSI) in the graphite tube atomizer. The furnace program included two drying steps (at 110 and 130 °C) to minimize the sputtering of the sample in the atomizer. In all instances, the pyrolysis, atomization and cleaning temperatures of 1600, 2400 and 2500 °C were used to obtain good peak profiles with low background signals without the addition of any chemical modifier. The method provides a linear range for chromium from 7.0 to 50 µg l−1 and a limit of detection of 4.0 µg l−1, which corresponds to 6.0 ng g−1. The results were precise (0.6–0.8% RSD) and the recovery values found in the analysis of spiked samples ranged from 99.2 to 102.2%. The agreement between the observed and certified values obtained from two NIST Standard Certified Materials was good. The method described is satisfactory for determining chromium in new and used lubricating oil samples.
- 19 April 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 15 (5) , 549-555
On-line emulsification of lubricating oils in a flow-injection system for chromium determination by electrothermal atomic absorption spectrometry
A simple and quick procedure has been developed for the on-line preparation of a one phase emulsion in a flow injection (FI) system for chromium determination by electrothermal atomic absorption spectrometry (ETAAS) with Zeeman-effect background correction. The entire FI system was controlled by a computer, independent of the spectrometer. A 1-ml plug of sample solution was injected into the carrier stream of hexane and was subsequently mixed with streams of 3.8% (m/v) sodium chloride, 5.0% (v/v) sodium dodecylsulfate (SDS) and 5.0% (v/v) of sec-butanol. The flow rates of the carrier, sodium chloride, SDS and sec-butanol streams were 1.0, 0.5, 0.5 and 0.2 ml min−1, respectively. The sonication of the flowing solutions improved the stability of the emulsion and provided quantitative recoveries. An emulsified sub-sample of 200-µl was collected in a capillary of a sampling arm assembly. Thereafter, 20 µl of this sample solution were introduced by means of positive displacement with air through a time-based solenoid injector (TBSI) in the graphite tube atomizer. The furnace program included two drying steps (at 110 and 130 °C) to minimize the sputtering of the sample in the atomizer. In all instances, the pyrolysis, atomization and cleaning temperatures of 1600, 2400 and 2500 °C were used to obtain good peak profiles with low background signals without the addition of any chemical modifier. The method provides a linear range for chromium from 7.0 to 50 µg l−1 and a limit of detection of 4.0 µg l−1, which corresponds to 6.0 ng g−1. The results were precise (0.6–0.8% RSD) and the recovery values found in the analysis of spiked samples ranged from 99.2 to 102.2%. The agreement between the observed and certified values obtained from two NIST Standard Certified Materials was good. The method described is satisfactory for determining chromium in new and used lubricating oil samples.