Fanglin Geng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fanglin Geng has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Peng Wang
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
4 shared publications - Xianxiang Chen
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
4 shared publications - Hao Zhang
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
3 shared publications - Lidong Du
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
3 shared publications - Zhen Fang
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
3 shared publications - Changyu Liu
Aerospace Information Research Institute, Chinese Academy of Sciences (AIRCAS), Beijing 100094, China
2 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3593
From Wave Manipulation to Programmable Apertures: A Review of Metasurface-Enabled Radar
Electromagnetic wave manipulation underpins radar detection, imaging, and electronic countermeasures. Conventional phased-array and radio-frequency-chain-based radar architectures provide mature and high-performance operation but can face practical constraints related to aperture profile, power and thermal management, calibration, bandwidth, and multifunctional integration. Electromagnetic metasurfaces provide a complementary approach by controlling the phase, amplitude, polarization, and frequency content of scattered or radiated fields through subwavelength surface elements. This article presents a radar-system-oriented review of metasurface-enabled wave manipulation. We first summarize the relevant physical mechanisms, including generalized scattering, digital and information metasurfaces, time-varying modulation, and polarization and geometric-phase control. We then review experimentally reported applications in radar-cross-section control, programmable beam steering, computational imaging, time-modulated radar, multiple-input multiple-output systems, and integrated sensing and communication. Particular attention is given to the level of experimental validation and to the distinction between measured device- or subsystem-level performance and anticipated system-level benefits. Potential applications in stealth, radar deception, low-probability-of-intercept-oriented operation, and cognitive sensing are discussed together with limitations in bandwidth, efficiency, power handling, biasing, calibration, thermal management, and scalability. Overall, the available literature indicates that metasurfaces can support selected aperture-level radar functions, whereas general system-level advantages in SWaP, cost, latency, and energy efficiency remain to be established through controlled comparative experiments.
- 12 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3593
Open AccessFrom Wave Manipulation to Programmable Apertures: A Review of Metasurface-Enabled Radar
Electromagnetic wave manipulation underpins radar detection, imaging, and electronic countermeasures. Conventional phased-array and radio-frequency-chain-based radar architectures provide mature and high-performance operation but can face practical constraints related to aperture profile, power and thermal management, calibration, bandwidth, and multifunctional integration. Electromagnetic metasurfaces provide a complementary approach by controlling the phase, amplitude, polarization, and frequency content of scattered or radiated fields through subwavelength surface elements. This article presents a radar-system-oriented review of metasurface-enabled wave manipulation. We first summarize the relevant physical mechanisms, including generalized scattering, digital and information metasurfaces, time-varying modulation, and polarization and geometric-phase control. We then review experimentally reported applications in radar-cross-section control, programmable beam steering, computational imaging, time-modulated radar, multiple-input multiple-output systems, and integrated sensing and communication. Particular attention is given to the level of experimental validation and to the distinction between measured device- or subsystem-level performance and anticipated system-level benefits. Potential applications in stealth, radar deception, low-probability-of-intercept-oriented operation, and cognitive sensing are discussed together with limitations in bandwidth, efficiency, power handling, biasing, calibration, thermal management, and scalability. Overall, the available literature indicates that metasurfaces can support selected aperture-level radar functions, whereas general system-level advantages in SWaP, cost, latency, and energy efficiency remain to be established through controlled comparative experiments.
- Open Access
- 1 June 2026
- Published by Tsinghua University Press in Tsinghua Science and Technology
- Vol. 31 (3) , 1802-1818
Privacy-Preserving Unobtrusive Fall Detection for Older Adults: A Highly Generalized Deep Anomaly Detection Model
Detecting and treating older adults who fall in an environment without others is essential. Millimeter-wave radar sensors do not have the disadvantage of invading user privacy like cameras, nor do they require users to wear them in real-time like wearable devices. Actual samples of older adults fall are difficult to collect, and it is unethical to require older adults to fall repeatedly to collect data. In addition, different body types and action patterns will inevitably reduce the model’s performance when new users use the model. In this paper, we constructed a fall detection model based on anomaly detection. The model is trained only using non-fall samples and detects falls as abnormal actions. The proposed model uses a domain generalization architecture based on domain feature alignment to extract domain-invariant features of the model, thereby improving the model’s generalization ability. In addition, we introduced the idea of denoising learning into the feature extractor and feature predictor to improve the model’s anti-interference ability. We conducted sufficient experiments to explore the effectiveness of the proposed method. When tested with new domain data, the proposed model has a true positive rate of 96.12%, a false positive rate of 0.97%, and an area under the receiver operating characteristic of 0.9979.
- 1 June 2026
- Published by Tsinghua University Press in Tsinghua Science and Technology
- Vol. 31 (3) , 1802-1818
Open AccessPrivacy-Preserving Unobtrusive Fall Detection for Older Adults: A Highly Generalized Deep Anomaly Detection Model
Detecting and treating older adults who fall in an environment without others is essential. Millimeter-wave radar sensors do not have the disadvantage of invading user privacy like cameras, nor do they require users to wear them in real-time like wearable devices. Actual samples of older adults fall are difficult to collect, and it is unethical to require older adults to fall repeatedly to collect data. In addition, different body types and action patterns will inevitably reduce the model’s performance when new users use the model. In this paper, we constructed a fall detection model based on anomaly detection. The model is trained only using non-fall samples and detects falls as abnormal actions. The proposed model uses a domain generalization architecture based on domain feature alignment to extract domain-invariant features of the model, thereby improving the model’s generalization ability. In addition, we introduced the idea of denoising learning into the feature extractor and feature predictor to improve the model’s anti-interference ability. We conducted sufficient experiments to explore the effectiveness of the proposed method. When tested with new domain data, the proposed model has a true positive rate of 96.12%, a false positive rate of 0.97%, and an area under the receiver operating characteristic of 0.9979.
- Open Access
- 2 December 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (12) , 1219
HSF-IBI: A Universal Framework for Extracting Inter-Beat Interval from Heterogeneous Unobtrusive Sensors
Heartbeat inter-beat interval (IBI) extraction is a crucial technology for unobtrusive vital sign monitoring, yet its precision and robustness remain challenging. A promising approach is fusing heartbeat signals from different types of unobtrusive sensors. This paper introduces HSF-IBI, a novel and universal framework for unobtrusive IBI extraction using heterogeneous sensor fusion. Specifically, harmonic summation (HarSum) is employed for calculating the average heart rate, which in turn guides the selection of the optimal band selection (OBS), the basic sequential algorithmic scheme (BSAS)-based template group extraction, and the template matching (TM) procedure. The optimal IBIs are determined by evaluating the signal quality index (SQI) for each heartbeat. The algorithm is morphology-independent and can be adapted to different sensors. The proposed algorithm framework is evaluated on a self-collected dataset including 19 healthy participants and an open-source dataset including 34 healthy participants, both containing heterogeneous sensors. The experimental results demonstrate that (1) the proposed framework successfully integrates data from heterogeneous sensors, leading to detection rate enhancements of 6.25 % and 5.21 % on two datasets, and (2) the proposed framework achieves superior accuracy over existing IBI extraction methods, with mean absolute errors (MAEs) of 5.25 ms and 4.56 ms on two datasets.
- 2 December 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (12) , 1219
Open AccessHSF-IBI: A Universal Framework for Extracting Inter-Beat Interval from Heterogeneous Unobtrusive Sensors
Heartbeat inter-beat interval (IBI) extraction is a crucial technology for unobtrusive vital sign monitoring, yet its precision and robustness remain challenging. A promising approach is fusing heartbeat signals from different types of unobtrusive sensors. This paper introduces HSF-IBI, a novel and universal framework for unobtrusive IBI extraction using heterogeneous sensor fusion. Specifically, harmonic summation (HarSum) is employed for calculating the average heart rate, which in turn guides the selection of the optimal band selection (OBS), the basic sequential algorithmic scheme (BSAS)-based template group extraction, and the template matching (TM) procedure. The optimal IBIs are determined by evaluating the signal quality index (SQI) for each heartbeat. The algorithm is morphology-independent and can be adapted to different sensors. The proposed algorithm framework is evaluated on a self-collected dataset including 19 healthy participants and an open-source dataset including 34 healthy participants, both containing heterogeneous sensors. The experimental results demonstrate that (1) the proposed framework successfully integrates data from heterogeneous sensors, leading to detection rate enhancements of 6.25 % and 5.21 % on two datasets, and (2) the proposed framework achieves superior accuracy over existing IBI extraction methods, with mean absolute errors (MAEs) of 5.25 ms and 4.56 ms on two datasets.
- Open Access
- 28 November 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (12) , 1203
Non-Contact Stable Arterial Pulse Measurement Using mmWave Array Radar
Pulse signals can serve as important indicators of one’s cardiovascular condition. However, capturing signals with stable morphology using radar under varying measurement periods remains a significant challenge. This paper reports a non-contact arterial pulse measurement method based on mmWave radar, with stable signals achieved through a range–angle focusing algorithm. A total of six subjects participated in the experiment, and the results showed that, under different measurement times, the pulse morphology of the same body part for each subject had good consistency, reaching a correlation of over 0.84, and four selected pulse signs remained stable. This is a quantitative assessment revealing a high correlation in pulse morphology measured by radar over different periods. In addition, the influence of array size and measurement distance was analyzed, providing a reference of array selection for research work with different requirements. This work offers an effective reference framework for long-term pulse measurement using radar technology.
- 28 November 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (12) , 1203
Open AccessNon-Contact Stable Arterial Pulse Measurement Using mmWave Array Radar
Pulse signals can serve as important indicators of one’s cardiovascular condition. However, capturing signals with stable morphology using radar under varying measurement periods remains a significant challenge. This paper reports a non-contact arterial pulse measurement method based on mmWave radar, with stable signals achieved through a range–angle focusing algorithm. A total of six subjects participated in the experiment, and the results showed that, under different measurement times, the pulse morphology of the same body part for each subject had good consistency, reaching a correlation of over 0.84, and four selected pulse signs remained stable. This is a quantitative assessment revealing a high correlation in pulse morphology measured by radar over different periods. In addition, the influence of array size and measurement distance was analyzed, providing a reference of array selection for research work with different requirements. This work offers an effective reference framework for long-term pulse measurement using radar technology.
- Open Access
Continuous and Noninvasive Measurement of Arterial Pulse Pressure and Pressure Waveform using an Image-free Ultrasound System
The local beat-to-beat local pulse pressure (PP) and blood pressure waveform of arteries, especially central arteries, are important indicators of the course of cardiovascular diseases (CVDs). Nevertheless, noninvasive measurement of them remains a challenge in the clinic. This work presents a three-element image-free ultrasound system with a low-computational method for real-time measurement of local pulse wave velocity (PWV) and diameter waveforms, enabling real-time and noninvasive continuous PP and blood pressure waveforms measurement without calibration. The developed system has been well-validated in vitro and in vivo. In in vitro cardiovascular phantom experiments, the results demonstrated high accuracy in the measurement of PP (error < 3 mmHg) and blood pressure waveform (root-mean-square-errors (RMSE) < 2 mmHg, correlation coefficient (r) > textgreater 0.99). In subsequent human carotid experiments, the system was compared with an arterial tonometer, which showed excellent PP accuracy (mean absolute error (MAE) = 3.7 +- 3.4 mmHg) and pressure waveform similarity (RMSE = 3.7 +- 1.6 mmHg, r = 0.98 +- 0.01). Furthermore, comparative experiments with the volume clamp device demonstrated the system's ability to accurately trace blood pressure changes (induced by deep breathing) over a period of one minute, with the MAE of DBP, MAP, and SBP within 5 +- 8 mmHg. The present results demonstrate the accuracy and reliability of the developed system for continuous and noninvasive measurement of arterial PP and blood pressure waveform measurements, with potential applications in the diagnosis and prevention of CVDs.
Open AccessContinuous and Noninvasive Measurement of Arterial Pulse Pressure and Pressure Waveform using an Image-free Ultrasound System
The local beat-to-beat local pulse pressure (PP) and blood pressure waveform of arteries, especially central arteries, are important indicators of the course of cardiovascular diseases (CVDs). Nevertheless, noninvasive measurement of them remains a challenge in the clinic. This work presents a three-element image-free ultrasound system with a low-computational method for real-time measurement of local pulse wave velocity (PWV) and diameter waveforms, enabling real-time and noninvasive continuous PP and blood pressure waveforms measurement without calibration. The developed system has been well-validated in vitro and in vivo. In in vitro cardiovascular phantom experiments, the results demonstrated high accuracy in the measurement of PP (error < 3 mmHg) and blood pressure waveform (root-mean-square-errors (RMSE) < 2 mmHg, correlation coefficient (r) > textgreater 0.99). In subsequent human carotid experiments, the system was compared with an arterial tonometer, which showed excellent PP accuracy (mean absolute error (MAE) = 3.7 +- 3.4 mmHg) and pressure waveform similarity (RMSE = 3.7 +- 1.6 mmHg, r = 0.98 +- 0.01). Furthermore, comparative experiments with the volume clamp device demonstrated the system's ability to accurately trace blood pressure changes (induced by deep breathing) over a period of one minute, with the MAE of DBP, MAP, and SBP within 5 +- 8 mmHg. The present results demonstrate the accuracy and reliability of the developed system for continuous and noninvasive measurement of arterial PP and blood pressure waveform measurements, with potential applications in the diagnosis and prevention of CVDs.