Shun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shun Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Changhong Linghu
Department of Mechanical Engineering, College of Engineering, City University of Hong Kong, Hong Kong, China
1 shared publication Chenglong Li
Huanjiang Laboratory, Key Laboratory of Soft Machines and Smart Devices of Zhejiang Province, State Key Laboratory of Brain-Machine Intelligence, Department of Engineering Mechanics, Zhejiang University, Hangzhou, China
1 shared publicationChunying Yao
Shaoxing Yuanju Technology Co., Ltd., Shaoxing, China
1 shared publication- Gang Feng
2nd Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou 310009, China
1 shared publication - Hao Jin
Zhejiang University
1 shared publication Jing Jiang
Huanjiang Laboratory, Key Laboratory of Soft Machines and Smart Devices of Zhejiang Province, State Key Laboratory of Brain-Machine Intelligence, Department of Engineering Mechanics, Zhejiang University, Hangzhou, China
1 shared publication
Latest Publications
- Open Access
- 4 September 2026
- Published by Springer Nature in Science China Materials
- Vol. 69 (11) , 7159-7172
Heating-mode-defined energy pathways govern non-contact release in shape memory polymer transfer printing
Smart dry adhesion underpins transfer printing technologies for flexible electronics, micro light-emitting diode (LED) displays, and heterogeneous optoelectronic integration. Shape memory polymer (SMP)-enabled embedded transfer printing offers strong pickup capability and operational flexibility, where pickup is realized through controlled embedding into SMP stamps via either global or localized heating. However, these distinct heating modes often result in markedly different non-contact release reliability for planar microchips, and the mechanistic origin of this discrepancy remains insufficiently understood, limiting deterministic transfer printing. Here, we establish an experimentally and numerically resolved mechanistic framework that links pickup heating mode to strain energy pathways and non-contact release reliability in SMP-enabled embedded transfer printing. Combining systematic experiments with finite element simulations incorporating a thermo-mechanically coupled SMP constitutive model under identical laser-triggered release conditions, we reveal that localized heating induces spatially confined modulus reduction and effective strain energy accumulation near the embedded microchip, enabling efficient energy release and reliable detachment. In contrast, global heating leads to delocalized energy storage across the SMP adhesive, leaving only a limited fraction of recoverable energy available for chip release. Parameter-dependent transitions between localized and delocalized deformation regions further clarify the conditions required for effective energy confinement during pickup. The programmable transfer and assembly of LED chips into flexible display devices validate the practical applicability of the localized heating mode. Collectively, these results establish an energy-based design framework that renders non-contact release in SMP-enabled embedded transfer printing predictable and scalable, supporting reliable heterogeneous integration and industrial translation of flexible and micro-optoelectronic systems.
- 4 September 2026
- Published by Springer Nature in Science China Materials
- Vol. 69 (11) , 7159-7172
Open AccessHeating-mode-defined energy pathways govern non-contact release in shape memory polymer transfer printing
Smart dry adhesion underpins transfer printing technologies for flexible electronics, micro light-emitting diode (LED) displays, and heterogeneous optoelectronic integration. Shape memory polymer (SMP)-enabled embedded transfer printing offers strong pickup capability and operational flexibility, where pickup is realized through controlled embedding into SMP stamps via either global or localized heating. However, these distinct heating modes often result in markedly different non-contact release reliability for planar microchips, and the mechanistic origin of this discrepancy remains insufficiently understood, limiting deterministic transfer printing. Here, we establish an experimentally and numerically resolved mechanistic framework that links pickup heating mode to strain energy pathways and non-contact release reliability in SMP-enabled embedded transfer printing. Combining systematic experiments with finite element simulations incorporating a thermo-mechanically coupled SMP constitutive model under identical laser-triggered release conditions, we reveal that localized heating induces spatially confined modulus reduction and effective strain energy accumulation near the embedded microchip, enabling efficient energy release and reliable detachment. In contrast, global heating leads to delocalized energy storage across the SMP adhesive, leaving only a limited fraction of recoverable energy available for chip release. Parameter-dependent transitions between localized and delocalized deformation regions further clarify the conditions required for effective energy confinement during pickup. The programmable transfer and assembly of LED chips into flexible display devices validate the practical applicability of the localized heating mode. Collectively, these results establish an energy-based design framework that renders non-contact release in SMP-enabled embedded transfer printing predictable and scalable, supporting reliable heterogeneous integration and industrial translation of flexible and micro-optoelectronic systems.
- Open Access
- 29 November 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (23) , 2695
Non-Invasive and Quantitative Evaluation for Disuse Muscle Atrophy Caused by Immobilization After Limb Fracture Based on Surface Electromyography Analysis
Background: The clinical evaluation for disuse muscle atrophy usually depends on qualitative rating indicators with subjective judgments of doctors and some invasive measurement methods such as needle electromyography. Surface electromyography, as a non-invasive method, has been widely used in the detection of muscular and neurological diseases in recent years. In this paper, we explore how to evaluate disuse muscle atrophy based on surface electromyography; Methods: Firstly, we conducted rat experiments using hind-limb suspension to create a model of disuse muscle atrophy. Five groups of rats were suspended for 0, 3, 7, 14, and 21 days, respectively. We induced leg electromyography of rats through electrical stimulation and used fluorescence staining to obtain the fiber-type composition of rats’ leg muscles. We obtained the best-fitting frequency bands of power spectrum density of surface electromyography for type I and type II fibers in rats’ leg muscles by changing the frequency band boundaries. Secondly, we conducted tests on the human body and collected the electromyography of the atrophied muscles of the subjects over a period of 21 days. The changes in muscle fiber composition were evaluated using the frequency bands of power spectrum density obtained from rat experiments. The method was to evaluate the changes in type I fibers by the changes in the area of the best-fitting frequency band of type I fibers and to evaluate the changes in type II fibers by the changes in the area of the best-fitting frequency band of type II fibers. Results: The results of rat experiments showed that type I fibers best fit the frequency band of 20–330 Hz and type II fibers best fit the frequency band of 176–500 Hz. The results of human testing showed that the atrophy of the two types of fibers was consistent with the changes in the areas of the corresponding best-fitting frequency bands. Conclusions: The test results demonstrate the feasibility of using surface electromyography to evaluate muscle fiber-type composition and subsequently assess muscle atrophy. Further research may contribute to the diagnosis and treatment of disuse muscle atrophy.
- 29 November 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (23) , 2695
Open AccessNon-Invasive and Quantitative Evaluation for Disuse Muscle Atrophy Caused by Immobilization After Limb Fracture Based on Surface Electromyography Analysis
Background: The clinical evaluation for disuse muscle atrophy usually depends on qualitative rating indicators with subjective judgments of doctors and some invasive measurement methods such as needle electromyography. Surface electromyography, as a non-invasive method, has been widely used in the detection of muscular and neurological diseases in recent years. In this paper, we explore how to evaluate disuse muscle atrophy based on surface electromyography; Methods: Firstly, we conducted rat experiments using hind-limb suspension to create a model of disuse muscle atrophy. Five groups of rats were suspended for 0, 3, 7, 14, and 21 days, respectively. We induced leg electromyography of rats through electrical stimulation and used fluorescence staining to obtain the fiber-type composition of rats’ leg muscles. We obtained the best-fitting frequency bands of power spectrum density of surface electromyography for type I and type II fibers in rats’ leg muscles by changing the frequency band boundaries. Secondly, we conducted tests on the human body and collected the electromyography of the atrophied muscles of the subjects over a period of 21 days. The changes in muscle fiber composition were evaluated using the frequency bands of power spectrum density obtained from rat experiments. The method was to evaluate the changes in type I fibers by the changes in the area of the best-fitting frequency band of type I fibers and to evaluate the changes in type II fibers by the changes in the area of the best-fitting frequency band of type II fibers. Results: The results of rat experiments showed that type I fibers best fit the frequency band of 20–330 Hz and type II fibers best fit the frequency band of 176–500 Hz. The results of human testing showed that the atrophy of the two types of fibers was consistent with the changes in the areas of the corresponding best-fitting frequency bands. Conclusions: The test results demonstrate the feasibility of using surface electromyography to evaluate muscle fiber-type composition and subsequently assess muscle atrophy. Further research may contribute to the diagnosis and treatment of disuse muscle atrophy.