Li Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Li Cao has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Bin Cheng
Department of Gastroenterology and Hepatology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
2 shared publications Da-Jin Wu
CCAST (World Laboratory), P.O. Box 8730, Beijing 100080, China
2 shared publications- Huai Zheng
School of Power and Mechanical Engineering, Wuhan University, Wuhan, China
2 shared publications Jinglong Zou
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publicationsQiaozhen Guo
A Department of Gastroenterology and Hepatology, Tongji Hospital, Tongji Medical College , Huazhong University of Science and Technology , Wuhan , China
2 shared publications- Xiaoping Liu
School of Computer and Information, Hefei University of Technology, Hefei, China
2 shared publications
Latest Publications
- Open Access
Controlling the Latent Diffusion Model for Generative Image Shadow Removal via Residual Generation
Large-scale generative models have achieved remarkable advancements in various visual tasks, yet their application to shadow removal in images remains challenging. These models often generate diverse, realistic details without adequate focus on fidelity, failing to meet the crucial requirements of shadow removal, which necessitates precise preservation of image content. In contrast to prior approaches that aimed to regenerate shadow-free images from scratch, this paper utilizes diffusion models to generate and refine image residuals. This strategy fully uses the inherent detailed information within shadowed images, resulting in a more efficient and faithful reconstruction of shadow-free content. Additionally, to revent the accumulation of errors during the generation process, a crosstimestep self-enhancement training strategy is proposed. This strategy leverages the network itself to augment the training data, not only increasing the volume of data but also enabling the network to dynamically correct its generation trajectory, ensuring a more accurate and robust output. In addition, to address the loss of original details in the process of image encoding and decoding of large generative models, a content-preserved encoder-decoder structure is designed with a control mechanism and multi-scale skip connections to achieve high-fidelity shadow-free image reconstruction. Experimental results demonstrate that the proposed method can reproduce high-quality results based on a large latent diffusion prior and faithfully preserve the original contents in shadow regions.
Open AccessControlling the Latent Diffusion Model for Generative Image Shadow Removal via Residual Generation
Large-scale generative models have achieved remarkable advancements in various visual tasks, yet their application to shadow removal in images remains challenging. These models often generate diverse, realistic details without adequate focus on fidelity, failing to meet the crucial requirements of shadow removal, which necessitates precise preservation of image content. In contrast to prior approaches that aimed to regenerate shadow-free images from scratch, this paper utilizes diffusion models to generate and refine image residuals. This strategy fully uses the inherent detailed information within shadowed images, resulting in a more efficient and faithful reconstruction of shadow-free content. Additionally, to revent the accumulation of errors during the generation process, a crosstimestep self-enhancement training strategy is proposed. This strategy leverages the network itself to augment the training data, not only increasing the volume of data but also enabling the network to dynamically correct its generation trajectory, ensuring a more accurate and robust output. In addition, to address the loss of original details in the process of image encoding and decoding of large generative models, a content-preserved encoder-decoder structure is designed with a control mechanism and multi-scale skip connections to achieve high-fidelity shadow-free image reconstruction. Experimental results demonstrate that the proposed method can reproduce high-quality results based on a large latent diffusion prior and faithfully preserve the original contents in shadow regions.
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 28 (3) , 447-452
A New Prewetting Process of Through Silicon Vias (TSV) Electroplating for 3D Integration
Three-dimensional (3-D) integration based on the through silicon via (TSV) technology involves the processes of wafer thinning, TSV etching and plating, re-distribution layer (RDL) formulation, and FC chip bonding. TSV plating is a key to the 3-D electrical interconnection, whereas the prewetting process is one of the important factors that can decide the filling depth and quality of the TSV plating. In this paper, a new three-step prewetting process with high efficiency and low cost is developed and includes absolute ethanol infiltration, deionized water washing, and a copper electrolyte bath. In the electroplating process, blind vias with an aspect ratio of 10:1 prewetted by our three-step prewetting process were fully filled. [2018-0190]
- 14 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Microelectromechanical Systems
- Vol. 28 (3) , 447-452
A New Prewetting Process of Through Silicon Vias (TSV) Electroplating for 3D Integration
Three-dimensional (3-D) integration based on the through silicon via (TSV) technology involves the processes of wafer thinning, TSV etching and plating, re-distribution layer (RDL) formulation, and FC chip bonding. TSV plating is a key to the 3-D electrical interconnection, whereas the prewetting process is one of the important factors that can decide the filling depth and quality of the TSV plating. In this paper, a new three-step prewetting process with high efficiency and low cost is developed and includes absolute ethanol infiltration, deionized water washing, and a copper electrolyte bath. In the electroplating process, blind vias with an aspect ratio of 10:1 prewetted by our three-step prewetting process were fully filled. [2018-0190]
- 4 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 9 (3) , 391-398
Study of Annular Copper-Filled TSVs of Sensor and Interposer Chips for 3-D Integration
Actually, 3D integrating process is often viewed as the integration of wafer thinning, through silicon vias (TSV) etching and filling, re-distribution layer (RDL) formulation as well as micro bump bonding. In which TSV formulation is a critical process because the TSV decides the quality of the interconnection. In this paper, annular copper filled TSVs are fabricated into the sensor and interposer chips, which are thinned to 100μm, and 10μm diameter TSV is etched and annular filled by 2μm thick copper only utilizing sputtering. It can significantly simplify the chip fabricating process, which only including TSV etching (DRIE), insulating layer formation, barrier layer and copper layer sputtering, and peeling. The thermal reliability of the annular filled TSV structure is studied by finite element simulation and it is found that the thermal stress is markedly reduced, and in the TCT tests, annularly filled TSV samples shows better reliability. Meanwhile the measured electrical conductivity shows a slightly worse but enough electrical conductivity property.
- 4 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 9 (3) , 391-398
Study of Annular Copper-Filled TSVs of Sensor and Interposer Chips for 3-D Integration
Actually, 3D integrating process is often viewed as the integration of wafer thinning, through silicon vias (TSV) etching and filling, re-distribution layer (RDL) formulation as well as micro bump bonding. In which TSV formulation is a critical process because the TSV decides the quality of the interconnection. In this paper, annular copper filled TSVs are fabricated into the sensor and interposer chips, which are thinned to 100μm, and 10μm diameter TSV is etched and annular filled by 2μm thick copper only utilizing sputtering. It can significantly simplify the chip fabricating process, which only including TSV etching (DRIE), insulating layer formation, barrier layer and copper layer sputtering, and peeling. The thermal reliability of the annular filled TSV structure is studied by finite element simulation and it is found that the thermal stress is markedly reduced, and in the TCT tests, annularly filled TSV samples shows better reliability. Meanwhile the measured electrical conductivity shows a slightly worse but enough electrical conductivity property.
- 13 November 2018
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 53 (12) , 1604-1610
The role of EUS-guided fine needle aspiration in autoimmune pancreatitis: a single center prospective study
Objectives: Histopathological examination is pivotal in diagnosing autoimmune pancreatitis (AIP). The usefulness of EUS-guided fine needle aspiration (EUS-FNA) in diagnosing AIP remains controversial worldwide. The authors conducted this study to evaluate the efficacy of EUS-FNA for AIP diagnosis using a 22-gauge needle. Methods: Between January 2013 and May 2017, 37 patients had imaging studies suggestive of AIP at Tongji Hospital, and 27 patients of them were enrolled in this study. Tissue specimens acquired through EUS-FNA were analyzed for periductal lymphoplasmacytic infiltrate (LPI), storiform fibrosis (SF), obliterative phlebitis (OP) and immunoglobulin G4 (IgG4)-positive plasma cell counts. Clinical Trials.gov no: TJ-C20121220. Results: LPI and SF were present in 18 (66.67%) and 18 (66.67%) of 27 patients, respectively. Abundant IgG4-positive plasmacyte infiltration >10/high-power field (HPF) was detected in 8 of 27 patients (29.63%). OP and the characteristic findings of idiopathic duct-centric chronic pancreatitis (IDCP) and granulocytic epithelial lesion (GEL) were not detected in this study. According to the International Consensus Diagnostic Criteria (ICDC) for AIP, 5 and 12 of 27 patients were assessed as having level 1 and level 2 histological findings, respectively, suggesting that 17 of 27 patients (62.96%) had lymphoplasmacytic sclerosing pancreatitis (LPSP) based on the ICDC. Conclusions: In 92.6% of patients, pancreatic tissues with >5 HPFs were obtained by EUS-FNA using a 22-G needle. In 63% of patients, histology was evaluated to be ≥ level 2 according to the ICDC. The study indicates that EUS-FNA with a 22-G needle is valuable in the histopathological diagnosis of AIP.
- 13 November 2018
- Published by Taylor & Francis in Scandinavian Journal of Gastroenterology
- Vol. 53 (12) , 1604-1610
The role of EUS-guided fine needle aspiration in autoimmune pancreatitis: a single center prospective study
Objectives: Histopathological examination is pivotal in diagnosing autoimmune pancreatitis (AIP). The usefulness of EUS-guided fine needle aspiration (EUS-FNA) in diagnosing AIP remains controversial worldwide. The authors conducted this study to evaluate the efficacy of EUS-FNA for AIP diagnosis using a 22-gauge needle. Methods: Between January 2013 and May 2017, 37 patients had imaging studies suggestive of AIP at Tongji Hospital, and 27 patients of them were enrolled in this study. Tissue specimens acquired through EUS-FNA were analyzed for periductal lymphoplasmacytic infiltrate (LPI), storiform fibrosis (SF), obliterative phlebitis (OP) and immunoglobulin G4 (IgG4)-positive plasma cell counts. Clinical Trials.gov no: TJ-C20121220. Results: LPI and SF were present in 18 (66.67%) and 18 (66.67%) of 27 patients, respectively. Abundant IgG4-positive plasmacyte infiltration >10/high-power field (HPF) was detected in 8 of 27 patients (29.63%). OP and the characteristic findings of idiopathic duct-centric chronic pancreatitis (IDCP) and granulocytic epithelial lesion (GEL) were not detected in this study. According to the International Consensus Diagnostic Criteria (ICDC) for AIP, 5 and 12 of 27 patients were assessed as having level 1 and level 2 histological findings, respectively, suggesting that 17 of 27 patients (62.96%) had lymphoplasmacytic sclerosing pancreatitis (LPSP) based on the ICDC. Conclusions: In 92.6% of patients, pancreatic tissues with >5 HPFs were obtained by EUS-FNA using a 22-G needle. In 63% of patients, histology was evaluated to be ≥ level 2 according to the ICDC. The study indicates that EUS-FNA with a 22-G needle is valuable in the histopathological diagnosis of AIP.
- Open Access
- 1 June 2018
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (26) , e11275
Foreign body embedded in the lower esophageal wall located by endoscopic ultrasonography
Ingested esophageal foreign bodies are commonly seen in adult population. In very few instances, esophageal foreign body may pass through the mucosal surface, re-epithelialize or migrate into surrounding soft tissues. A 55-year-old Chinese male was admitted to our hospital with a 10-day history chest and upper abdominal pain without dysphasia, cough or other symptoms. We initially suspected chronic gastritis, and thoracic computed tomography and endoscopy ultrasonography (EUS) were used to identify a fish bone completely embedded within the lower esophageal wall. Under the EUS-guidance, we marked the foreign body using methylene blue with saline solution, which was followed by successful thoracoscopy and surgical removed of the foreign body. The patient recovered well and was discharged 1 week postoperatively. One month postoperatively, the patient was symptom free and the chest wound was complete healed. Our case showed that computed tomography is necessary to diagnose the esophageal foreign body, and EUS may help confirm the position of foreign body, especially those embedded in the esophageal submucosa. We advocate necessary surgery at the first accurate diagnosis in patient with esophageal foreign body when endoscopy is not possible.
- 1 June 2018
- Published by Wolters Kluwer Health in Medicine
- Vol. 97 (26) , e11275
Open AccessForeign body embedded in the lower esophageal wall located by endoscopic ultrasonography
Ingested esophageal foreign bodies are commonly seen in adult population. In very few instances, esophageal foreign body may pass through the mucosal surface, re-epithelialize or migrate into surrounding soft tissues. A 55-year-old Chinese male was admitted to our hospital with a 10-day history chest and upper abdominal pain without dysphasia, cough or other symptoms. We initially suspected chronic gastritis, and thoracic computed tomography and endoscopy ultrasonography (EUS) were used to identify a fish bone completely embedded within the lower esophageal wall. Under the EUS-guidance, we marked the foreign body using methylene blue with saline solution, which was followed by successful thoracoscopy and surgical removed of the foreign body. The patient recovered well and was discharged 1 week postoperatively. One month postoperatively, the patient was symptom free and the chest wound was complete healed. Our case showed that computed tomography is necessary to diagnose the esophageal foreign body, and EUS may help confirm the position of foreign body, especially those embedded in the esophageal submucosa. We advocate necessary surgery at the first accurate diagnosis in patient with esophageal foreign body when endoscopy is not possible.
- 29 March 2018
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 77 (9) , 10979-10993
Evaluation of Local Features for Structure from Motion
- 29 March 2018
- Published by Springer Nature in Multimedia Tools and Applications
- Vol. 77 (9) , 10979-10993
Evaluation of Local Features for Structure from Motion
- 1 March 2017
- Published by IATED Academy
- Vol. 1, 7219
A STUDY ON THE EFFECT OF VISUALIZATION IN TEACHING ENTITY-RELATIONSHIP DIAGRAM (ERD) TO RELATIONAL SCHEMA MAPPING
Information about the paper titled "A STUDY ON THE EFFECT OF VISUALIZATION IN TEACHING ENTITY-RELATIONSHIP DIAGRAM (ERD) TO RELATIONAL SCHEMA MAPPING" at IATED Digital Library
- 1 March 2017
- Published by IATED Academy
- Vol. 1, 7219
A STUDY ON THE EFFECT OF VISUALIZATION IN TEACHING ENTITY-RELATIONSHIP DIAGRAM (ERD) TO RELATIONAL SCHEMA MAPPING
Information about the paper titled "A STUDY ON THE EFFECT OF VISUALIZATION IN TEACHING ENTITY-RELATIONSHIP DIAGRAM (ERD) TO RELATIONAL SCHEMA MAPPING" at IATED Digital Library
- 15 November 2010
- Published by IOP Publishing in Communications in Theoretical Physics
- Vol. 54 (5) , 875-878
Phenomenon of Resonance in a Two-Mode Laser with an Input Additive Signal
Exact formulas for the power spectrum and signal-to-noise ratio (SNR) with periodic additive signal are calculated in the linear system. Then the phenomenon of resonance is studied in detail. We show that resonance peak and suppressed valley exist in the curves of the SNR versus the coefficient of self-saturation, the net gain and the cross-coupling coefficient of the laser system.
- 15 November 2010
- Published by IOP Publishing in Communications in Theoretical Physics
- Vol. 54 (5) , 875-878
Phenomenon of Resonance in a Two-Mode Laser with an Input Additive Signal
Exact formulas for the power spectrum and signal-to-noise ratio (SNR) with periodic additive signal are calculated in the linear system. Then the phenomenon of resonance is studied in detail. We show that resonance peak and suppressed valley exist in the curves of the SNR versus the coefficient of self-saturation, the net gain and the cross-coupling coefficient of the laser system.
- 26 October 2004
- Published by IOP Publishing in Chinese Physics
- Vol. 13 (11) , 1811-1814
Stochastic resonance of bias signal-modulated noise in a single-mode laser
- 26 October 2004
- Published by IOP Publishing in Chinese Physics
- Vol. 13 (11) , 1811-1814
Stochastic resonance of bias signal-modulated noise in a single-mode laser
- 1 June 1999
- Published by American Physical Society (APS) in Physical Review E
- Vol. 59 (6) , R6235-R6238
Effect of correlation between additive and multiplicative noises on the activation from a double well
We study the thermal activation problem of a bistable system driven by correlated additive and multiplicative noises by means of numerical simulation. We find that in the colored noise case the suppression effect of the positive correlation decreases and finally is released as the autocorrelation time τ of the colored noise grows. When τ is large enough, negative correlation becomes more suppressive than the positive correlation. Such phenomena are ascribed to the collaboration between noises as well as the memory effect of the multiplicative colored noise.
- 1 June 1999
- Published by American Physical Society (APS) in Physical Review E
- Vol. 59 (6) , R6235-R6238
Effect of correlation between additive and multiplicative noises on the activation from a double well
We study the thermal activation problem of a bistable system driven by correlated additive and multiplicative noises by means of numerical simulation. We find that in the colored noise case the suppression effect of the positive correlation decreases and finally is released as the autocorrelation time τ of the colored noise grows. When τ is large enough, negative correlation becomes more suppressive than the positive correlation. Such phenomena are ascribed to the collaboration between noises as well as the memory effect of the multiplicative colored noise.