Shuaidong Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuaidong Huang has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Yiyi Zhao
Xi'an Institute of Optics and Precision Mechanics Chinese Academy of Science Xi'an China
2 shared publicationsBin Xue
Xi'an Institute of Optics and Precision Mechanics Chinese Academy of Science Xi'an China
1 shared publicationJianfeng Yang
Xi'an Institute of Optics and Precision Mechanics Chinese Academy of Science Xi'an China
1 shared publication- Jianfeng Yang
The Univ. of New South Wales (Australia)
1 shared publication - Shengrun Liu
Xi’an Institute of Optics and Precision Mechanics (China)
1 shared publication - Zhicong Li
Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an 710119, China
1 shared publication
Latest Publications
- 30 January 2024
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 55 (5) , 625-636
Characterization of primary silicate minerals in Earth‐like bodies via Raman spectroscopy
The examination and identification of silicate minerals are critical for advancing our understanding of the evolutionary journey of Earth‐like bodies. To facilitate an efficient and productive process, it is imperative that these minerals be detected swiftly and accurately. This study is designed to explore the relationship between varying concentrations of cations and their corresponding Raman shifts. The focus is on primary silicate minerals in Earth‐like bodies, specifically olivine, pyroxene, and feldspar, utilizing data from the RRUFF database. Employing a fitting formula, we identify distinct Raman peak ranges associated with different silicate minerals. Our research covers a wide array of mineral types, including five varieties of olivine (forsterite [Mg2SiO4], fayalite [Fe2+2SiO4], tephroite [Mn2+2SiO4], monticellite [CaMgSiO4], and kirschsteinite [CaFe2+SiO4]), four types of pyroxene (ferrosilite [Fe2+2Si2O6], enstatite [Mg2Si2O6], hedenbergite [CaFe2+Si2O6], and diopside [CaMgSi2O6]), and three varieties of feldspar (alkali feldspar [KAlSi3O8], albite [NaAlSi3O8], and anorthite [CaAl2Si2O8]). The accuracy of matching Raman characteristics is exceptionally high for all olivine and pyroxene types (100%) and an impressive 86% for feldspar. The findings from this study highlight the crucial role of Raman spectroscopy in the field of silicate mineralogy and suggest significant implications for enhancing future exploration missions to Earth‐like bodies.
- 30 January 2024
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 55 (5) , 625-636
Characterization of primary silicate minerals in Earth‐like bodies via Raman spectroscopy
The examination and identification of silicate minerals are critical for advancing our understanding of the evolutionary journey of Earth‐like bodies. To facilitate an efficient and productive process, it is imperative that these minerals be detected swiftly and accurately. This study is designed to explore the relationship between varying concentrations of cations and their corresponding Raman shifts. The focus is on primary silicate minerals in Earth‐like bodies, specifically olivine, pyroxene, and feldspar, utilizing data from the RRUFF database. Employing a fitting formula, we identify distinct Raman peak ranges associated with different silicate minerals. Our research covers a wide array of mineral types, including five varieties of olivine (forsterite [Mg2SiO4], fayalite [Fe2+2SiO4], tephroite [Mn2+2SiO4], monticellite [CaMgSiO4], and kirschsteinite [CaFe2+SiO4]), four types of pyroxene (ferrosilite [Fe2+2Si2O6], enstatite [Mg2Si2O6], hedenbergite [CaFe2+Si2O6], and diopside [CaMgSi2O6]), and three varieties of feldspar (alkali feldspar [KAlSi3O8], albite [NaAlSi3O8], and anorthite [CaAl2Si2O8]). The accuracy of matching Raman characteristics is exceptionally high for all olivine and pyroxene types (100%) and an impressive 86% for feldspar. The findings from this study highlight the crucial role of Raman spectroscopy in the field of silicate mineralogy and suggest significant implications for enhancing future exploration missions to Earth‐like bodies.
- 29 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 774-3279
Optimization of focusing position in laser induced breakdown spectroscopy system based on quantitative analysis internal standard method of steel
A laser induced breakdown spectroscopy (LIBS) system has many experimental key parameter factors. Focusing position in laser induced breakdown spectroscopy (LIBS) system is an experimental key parameter factor. The optimization of spectral intensity has been studied, but the results are often inaccurate. In this Letter, A quantitative analysis internal standard method was proposed to optimize the parameter of LIBS experimental system. One 100mm focusing lens and eight standard alloy steels with rich element content were employed as samples. By employing internal standard method, the minority elements (Mn, Cr, Cu) in steels were quantitatively analyzed and the element detection sensitivity was obtained. The limit of detection (LOD) of the minority elements under different focusing states was calculated, and finally the optimal focus position was obtained. The result which indirectly shows that the best laser focusing position of LIBS system with 100mm focusing lens is 6mm below the surface of samples, and the limit of detection (LOD) of the minority elements maintain the minimum value at this position (0.00159 wt.%), which indicates that the quantitative analysis method is effective and reliable for optimizing the parameters of LIBS system.
- 29 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12169, 774-3279
Optimization of focusing position in laser induced breakdown spectroscopy system based on quantitative analysis internal standard method of steel
A laser induced breakdown spectroscopy (LIBS) system has many experimental key parameter factors. Focusing position in laser induced breakdown spectroscopy (LIBS) system is an experimental key parameter factor. The optimization of spectral intensity has been studied, but the results are often inaccurate. In this Letter, A quantitative analysis internal standard method was proposed to optimize the parameter of LIBS experimental system. One 100mm focusing lens and eight standard alloy steels with rich element content were employed as samples. By employing internal standard method, the minority elements (Mn, Cr, Cu) in steels were quantitatively analyzed and the element detection sensitivity was obtained. The limit of detection (LOD) of the minority elements under different focusing states was calculated, and finally the optimal focus position was obtained. The result which indirectly shows that the best laser focusing position of LIBS system with 100mm focusing lens is 6mm below the surface of samples, and the limit of detection (LOD) of the minority elements maintain the minimum value at this position (0.00159 wt.%), which indicates that the quantitative analysis method is effective and reliable for optimizing the parameters of LIBS system.