Feiyu Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Feiyu Zhu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Weihua Chen
Faculty of Electrical and Control Engineering Liaoning Technical University Huludao City China
4 shared publications- Xiaoheng Yan
Liaoning Technical University
4 shared publications - Weihua Chen
School of Electrical and Control Engineering, Liaoning Technical University, Huludao, China
3 shared publications - Weiyi Huang
Liaoning Technical University
3 shared publications Xiaoheng Yan
Faculty of Electrical and Control Engineering Liaoning Technical University Huludao City China
2 shared publications- Chao Wang
Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China
1 shared publication
Latest Publications
- 22 March 2026
- Published by Wiley in International Journal of Circuit Theory and Applications
Research on Composite Shielding of Sector‐Shaped Coil for Resonant Wireless Power Supply Cardiac Pacemaker
In response to the issues of severe magnetic leakage in the wireless power transfer (WPT) system for cardiac pacemaker, which poses a threat to human safety, this paper proposes a composite shielding method for a resonant wireless power supply cardiac pacemaker sector‐shaped coil operating at a frequency of 180 kHz. Firstly, the working principle of the sector‐shaped shielding coil is analyzed, and a WPT system based on the LCC‐S compensation circuit is constructed. The structural parameters of the system are determined by optimizing the coupling coefficient between the transmission coils. Secondly, in order to investigate the influence of the central angle on the shielding performance of the circumferential sector‐shaped shielding coil, five different shielding schemes are designed and their magnetic field leakage confinement capabilities as well as system performance are studied. Considering the potential risks of leakage magnetic fields to human health, a human model is established in COMSOL for safety assessment. Finally, an experimental platform is designed and constructed. The experimental results show that, after incorporating the 120° circumferential sector‐shaped shielding coil and composite shielding material, the leakage magnetic field at a distance of 36 mm from the center decreases by 34.7%, and the transmission efficiency is 72.3%. Under a 30‐min charging test, the maximum tissue temperature rise is only 1.2°C, which complies with human safety standards.
- 22 March 2026
- Published by Wiley in International Journal of Circuit Theory and Applications
Research on Composite Shielding of Sector‐Shaped Coil for Resonant Wireless Power Supply Cardiac Pacemaker
In response to the issues of severe magnetic leakage in the wireless power transfer (WPT) system for cardiac pacemaker, which poses a threat to human safety, this paper proposes a composite shielding method for a resonant wireless power supply cardiac pacemaker sector‐shaped coil operating at a frequency of 180 kHz. Firstly, the working principle of the sector‐shaped shielding coil is analyzed, and a WPT system based on the LCC‐S compensation circuit is constructed. The structural parameters of the system are determined by optimizing the coupling coefficient between the transmission coils. Secondly, in order to investigate the influence of the central angle on the shielding performance of the circumferential sector‐shaped shielding coil, five different shielding schemes are designed and their magnetic field leakage confinement capabilities as well as system performance are studied. Considering the potential risks of leakage magnetic fields to human health, a human model is established in COMSOL for safety assessment. Finally, an experimental platform is designed and constructed. The experimental results show that, after incorporating the 120° circumferential sector‐shaped shielding coil and composite shielding material, the leakage magnetic field at a distance of 36 mm from the center decreases by 34.7%, and the transmission efficiency is 72.3%. Under a 30‐min charging test, the maximum tissue temperature rise is only 1.2°C, which complies with human safety standards.
- 4 February 2026
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 54 (11) , 5277-5290
A Wireless Power Transfer System for Cardiac Pacemakers Based on Flexible Dual‐Magnetic‐Negative Metamaterial Array
To address the low power transfer efficiency (PTE) of wireless power transfer (WPT) systems for cardiac pacemakers and the limited conformability of conventional metamaterials to the curvature of the human body, this paper proposes a WPT system for cardiac pacemakers based on a flexible dual‐magnetic‐negative metamaterial array. First, the influence of the geometric parameters of the flexible magnetic‐negative metamaterial (MNG) units on the PTE of the WPT system is analyzed. The number of turns, trace width, and inter‐turn spacing are then optimized to maximize the PTE. Next, based on the negative refraction characteristics of the unit, a flexible dual‐magnetic‐negative metamaterial array composed of two types of negative‐permeability units is constructed. The improvement in the transmission performance of the WPT system, as well as its safety, is evaluated through simulations and experiments under bending angles ranging from 0° to 50°. Experimental results show that at a transmission distance of 20 mm, the integration of the flexible dual‐magnetic‐negative metamaterial array increases the PTE of the WPT system by at least 38.47%. When the receiving coil experiences lateral misalignment and angular deviation, the system maintains transmission efficiencies of 28.35% and 24.22%, respectively. During a 30‐min charging test, the maximum temperature rise in the surrounding tissue is 1.8°C, which complies with human safety standards.
- 4 February 2026
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 54 (11) , 5277-5290
A Wireless Power Transfer System for Cardiac Pacemakers Based on Flexible Dual‐Magnetic‐Negative Metamaterial Array
To address the low power transfer efficiency (PTE) of wireless power transfer (WPT) systems for cardiac pacemakers and the limited conformability of conventional metamaterials to the curvature of the human body, this paper proposes a WPT system for cardiac pacemakers based on a flexible dual‐magnetic‐negative metamaterial array. First, the influence of the geometric parameters of the flexible magnetic‐negative metamaterial (MNG) units on the PTE of the WPT system is analyzed. The number of turns, trace width, and inter‐turn spacing are then optimized to maximize the PTE. Next, based on the negative refraction characteristics of the unit, a flexible dual‐magnetic‐negative metamaterial array composed of two types of negative‐permeability units is constructed. The improvement in the transmission performance of the WPT system, as well as its safety, is evaluated through simulations and experiments under bending angles ranging from 0° to 50°. Experimental results show that at a transmission distance of 20 mm, the integration of the flexible dual‐magnetic‐negative metamaterial array increases the PTE of the WPT system by at least 38.47%. When the receiving coil experiences lateral misalignment and angular deviation, the system maintains transmission efficiencies of 28.35% and 24.22%, respectively. During a 30‐min charging test, the maximum temperature rise in the surrounding tissue is 1.8°C, which complies with human safety standards.
- 1 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (2) , 2059-2068
Magnetic Structure Design for Drone WPT With Ultra-Low Stray Magnetic Fields and High Anti-Offset Performance
- 1 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (2) , 2059-2068
Magnetic Structure Design for Drone WPT With Ultra-Low Stray Magnetic Fields and High Anti-Offset Performance
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (3) , 3976-3987
A High-Performance Wireless Power Transfer System for Cardiac Pacemaker Based on Multi-MNG
In response to the issues of low transmission efficiency, poor offset tolerance, and severe magnetic leakage in wireless energy transmission systems for cardiac pacemakers, this paper presents a novel wireless power transfer system for cardiac pacemakers based on Multi- magnetic negative materials(Multi-MNG). Based on the theory of equivalent medium for magnetic negative materials (MNG) and the distribution of magnetic fields, three different metamaterial units with varying magnetic permeabilities are designed and arranged in a mixed manner to ensure effective convergence of the system's magnetic field, shield magnetic field leakage, and reduce Specific Absorption Rate (SAR). The accuracy, high efficiency, robustness, and safety of the Multi-MNG system's transmission are validated through simulations at 8.94MHz, and it mitigates the impact of magnetic leakage on the human body without a significant decrease in transmission performance. The maximum SAR value of the system is 0.0000504. The transmission performance of the Multi-MNG system is compared with that of ferrite, an unshielded MNG array 1 system, and a traditional system. The experiment unequivocally verifies the high performance of the Multi-MNG system, with a demonstrated maximum system output power of 1.323W and a transmission efficiency peaking at 72.1%, The temperature rise is 2.9°C, which meets human safety standards.
- 21 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (3) , 3976-3987
A High-Performance Wireless Power Transfer System for Cardiac Pacemaker Based on Multi-MNG
In response to the issues of low transmission efficiency, poor offset tolerance, and severe magnetic leakage in wireless energy transmission systems for cardiac pacemakers, this paper presents a novel wireless power transfer system for cardiac pacemakers based on Multi- magnetic negative materials(Multi-MNG). Based on the theory of equivalent medium for magnetic negative materials (MNG) and the distribution of magnetic fields, three different metamaterial units with varying magnetic permeabilities are designed and arranged in a mixed manner to ensure effective convergence of the system's magnetic field, shield magnetic field leakage, and reduce Specific Absorption Rate (SAR). The accuracy, high efficiency, robustness, and safety of the Multi-MNG system's transmission are validated through simulations at 8.94MHz, and it mitigates the impact of magnetic leakage on the human body without a significant decrease in transmission performance. The maximum SAR value of the system is 0.0000504. The transmission performance of the Multi-MNG system is compared with that of ferrite, an unshielded MNG array 1 system, and a traditional system. The experiment unequivocally verifies the high performance of the Multi-MNG system, with a demonstrated maximum system output power of 1.323W and a transmission efficiency peaking at 72.1%, The temperature rise is 2.9°C, which meets human safety standards.
- 22 November 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 53 (8) , 4874-4889
Wireless Power Transfer System for Cardiac Pacemakers Based on Spiral Ring mu‐Negative Materials
Considering the impact of metamaterials on the magnetic coupling effect and electromagnetic response characteristics in wireless power transfer systems for implantable cardiac pacemakers, this paper proposes a wireless power transfer system operating at the 300‐kHz frequency band, enhanced by spiral ring mu‐negative materials (SR‐MNG) to improve magnetic coupling efficiency. First, based on the resonance principle, the SR‐MNG is designed, and the system's mutual inductance coupling is analyzed using the magnetic dipole coupling model theory. Second, the impact of metamaterial thickness and loss on the system's coupling strength is investigated, and the performance of the system is analyzed when using FR4, polyimide, and aluminum nitride as dielectric substrate. The system's tolerance to misalignment is discussed bearing in mind the special implantation environment of the peacemaker. The experimental results indicate that, at a transmission distance of 20 mm, the system achieves optimal magnetic coupling strength with a thickness of 1.6 mm, resulting in a minimum power transmission efficiency of 71%. Increasing the thickness to 2 mm disrupts the trend of increasing efficiency, causing it to drop by at least 23.3%. The SR‐MNG with polyimide as the dielectric plate performs exceptionally well, maintaining an efficiency range of 17.3%–73.1% for lateral displacements between 0 and 30 mm and achieving a minimum efficiency of 39.2% for angular misalignment of 15°.
- 22 November 2024
- Published by Wiley in International Journal of Circuit Theory and Applications
- Vol. 53 (8) , 4874-4889
Wireless Power Transfer System for Cardiac Pacemakers Based on Spiral Ring mu‐Negative Materials
Considering the impact of metamaterials on the magnetic coupling effect and electromagnetic response characteristics in wireless power transfer systems for implantable cardiac pacemakers, this paper proposes a wireless power transfer system operating at the 300‐kHz frequency band, enhanced by spiral ring mu‐negative materials (SR‐MNG) to improve magnetic coupling efficiency. First, based on the resonance principle, the SR‐MNG is designed, and the system's mutual inductance coupling is analyzed using the magnetic dipole coupling model theory. Second, the impact of metamaterial thickness and loss on the system's coupling strength is investigated, and the performance of the system is analyzed when using FR4, polyimide, and aluminum nitride as dielectric substrate. The system's tolerance to misalignment is discussed bearing in mind the special implantation environment of the peacemaker. The experimental results indicate that, at a transmission distance of 20 mm, the system achieves optimal magnetic coupling strength with a thickness of 1.6 mm, resulting in a minimum power transmission efficiency of 71%. Increasing the thickness to 2 mm disrupts the trend of increasing efficiency, causing it to drop by at least 23.3%. The SR‐MNG with polyimide as the dielectric plate performs exceptionally well, maintaining an efficiency range of 17.3%–73.1% for lateral displacements between 0 and 30 mm and achieving a minimum efficiency of 39.2% for angular misalignment of 15°.