Ji Ma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ji Ma has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bo Gao
School of Energy and Power Engineering, Jiangsu University 1 , Zhenjiang 212013
2 shared publications Wanbo Yu
2 shared publications- Wenjie Zhou
School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, China
2 shared publications Zhenlai Ma
2 shared publications- Huihao Su
School of Energy and Power Engineering, Jiangsu University 1 , Zhenjiang 212013
1 shared publication
Latest Publications
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Multi-scale fluid-induced vibration characteristics of centrifugal pump based on fluid–structure interaction method
Fluid-induced vibration (FIV) is a key factor in low-frequency vibration of centrifugal pumps. This study focuses on a vertical low-specific-speed centrifugal pump and adopts an excitation source-transmission path-vibration response framework to better predict the FIV. The inner characteristics of the entire flow field were investigated based on fluid–structure interaction. The relative errors between the experimental and simulated results are 2.26% and 1.01% for efficiency and head at design point, respectively. In addition, the fluid-induced excitation and vibration characteristics of the centrifugal pump were further explored from the point of view of vibration transmission in pump unit. The results indicate that the blade passing frequency fBPF is the primary frequency governing the pressure pulsations and vibration characteristics of the centrifugal pump. The total vibration acceleration levels (TVALs) at various locations of the centrifugal pump increase with the flow rate. In the low-frequency range, the TVAL at the vibration absorber reaches its maximum at 108 dB, while the TVAL at the inlet flange is the lowest at 88 dB.
- 1 February 2025
- Published by AIP Publishing in Physics of Fluids
- Vol. 37 (2)
Multi-scale fluid-induced vibration characteristics of centrifugal pump based on fluid–structure interaction method
Fluid-induced vibration (FIV) is a key factor in low-frequency vibration of centrifugal pumps. This study focuses on a vertical low-specific-speed centrifugal pump and adopts an excitation source-transmission path-vibration response framework to better predict the FIV. The inner characteristics of the entire flow field were investigated based on fluid–structure interaction. The relative errors between the experimental and simulated results are 2.26% and 1.01% for efficiency and head at design point, respectively. In addition, the fluid-induced excitation and vibration characteristics of the centrifugal pump were further explored from the point of view of vibration transmission in pump unit. The results indicate that the blade passing frequency fBPF is the primary frequency governing the pressure pulsations and vibration characteristics of the centrifugal pump. The total vibration acceleration levels (TVALs) at various locations of the centrifugal pump increase with the flow rate. In the low-frequency range, the TVAL at the vibration absorber reaches its maximum at 108 dB, while the TVAL at the inlet flange is the lowest at 88 dB.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Fluid–structure interaction on the rotor-dynamic characteristics of a low-specific-speed centrifugal pump considering multi-scale fluid excitation effects
Centrifugal pump rotor system is a complex vibration system due to the unsteady multi-scale fluid–solid interactions (FSIs). In order to explore the coupling vibration of the rotor system between the multi-scale fluid domain and different flow conditions, the bidirectional fluid–solid interaction (BFSI) was carried out, and the numerical and experimental results of the centrifugal pump performance were compared. The transient forces of the impeller and vibration characteristics of rotor system considering BFSI for different flow rates, wear-ring clearances, and axial movements were also studied in detail. The results show that the maximum errors of head and efficiency between the simulation and experiment are only 5.41% and 2.33%, respectively. The radial force of impeller is smallest at 1.0Qd and the axial force decreases with the increase in flow rate. The average deformation and stress of the rotor system reaches to 0.35 mm and 70.7 MPa, respectively, when the axial movement increases to +1.5 mm. The vibration acceleration on the blades increases gradually from the root to the top, and the vibration acceleration on the shaft is greater than that at the impeller.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Fluid–structure interaction on the rotor-dynamic characteristics of a low-specific-speed centrifugal pump considering multi-scale fluid excitation effects
Centrifugal pump rotor system is a complex vibration system due to the unsteady multi-scale fluid–solid interactions (FSIs). In order to explore the coupling vibration of the rotor system between the multi-scale fluid domain and different flow conditions, the bidirectional fluid–solid interaction (BFSI) was carried out, and the numerical and experimental results of the centrifugal pump performance were compared. The transient forces of the impeller and vibration characteristics of rotor system considering BFSI for different flow rates, wear-ring clearances, and axial movements were also studied in detail. The results show that the maximum errors of head and efficiency between the simulation and experiment are only 5.41% and 2.33%, respectively. The radial force of impeller is smallest at 1.0Qd and the axial force decreases with the increase in flow rate. The average deformation and stress of the rotor system reaches to 0.35 mm and 70.7 MPa, respectively, when the axial movement increases to +1.5 mm. The vibration acceleration on the blades increases gradually from the root to the top, and the vibration acceleration on the shaft is greater than that at the impeller.