Chenying Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Interests
Chenying Zhang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Shaoyu Liu
Department of Mechanical & Electrical Engineering, Xiamen University, Xiamen 361005, China
2 shared publications - Wei Zhou
Beijing National Laboratory for Molecular Science New Cornerstone Science Laboratory College of Chemistry and Molecular Engineering Peking University Beijing China
2 shared publications - Charles Bu
Department of Mathematics, Wellesley College, Wellesley, MA 02481, USA
1 shared publication - Giorgio Pavesi
Università degli Studi di Padova
1 shared publication - Guobiao Zhang
School of Engineering and Technology, China University of Geosciences, Beijing 100083, China
1 shared publication Haotian She
School of Mechatronical Engineering, Beijing Institute of Technology, Beijing 100080, China
1 shared publication
Latest Publications
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Unstable flow analysis of transient process in the pump as turbine during turbine mode caused by pump power failure
Mixed-flow pump as turbines (PATs) serve as pivotal components within energy micro-grids, facilitating energy conversion and storage. However, the emergence of pressure pulsations in these systems can markedly affect their stability and efficiency, especially in pump power failure. To simulate the power-off transition accurately, the commercial computational fluid dynamics code ANSYS CFX® is integrated by a Fortran program through ANSYS parametric design language in the transient simulation to enable real-time iterative calculations of angular momentum equations for mixed-flow PAT at varying speeds. This study integrates the analysis of radial forces, vortices, and flow lines to elucidate the sudden changes in pressure pulsations observed during the transition stages. Specifically, significant fluctuations in the amplitude of pressure pulsations at the volute tongue were found for various initial flow rates, which correlated closely with changes in radial forces. The sudden increase and nonuniform distribution of radial forces emerged as the main factors of these fluctuations. In addition, the study reveals that the intensity of pressure fluctuations evidenced by wavelet time-frequency analysis on the pressure surface of the blade significantly exceeds that on the back surface of the blade. Furthermore, in the flow characteristics inside the draft tube, the pressure pulsation signals are mainly concentrated in the low-frequency region and are accompanied by the presence of a double-helix structure. These results provide an important reference for further understanding of the operating mechanism of the mixed-flow pump as a turbine, which helps to optimize the design and improve the performance.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Unstable flow analysis of transient process in the pump as turbine during turbine mode caused by pump power failure
Mixed-flow pump as turbines (PATs) serve as pivotal components within energy micro-grids, facilitating energy conversion and storage. However, the emergence of pressure pulsations in these systems can markedly affect their stability and efficiency, especially in pump power failure. To simulate the power-off transition accurately, the commercial computational fluid dynamics code ANSYS CFX® is integrated by a Fortran program through ANSYS parametric design language in the transient simulation to enable real-time iterative calculations of angular momentum equations for mixed-flow PAT at varying speeds. This study integrates the analysis of radial forces, vortices, and flow lines to elucidate the sudden changes in pressure pulsations observed during the transition stages. Specifically, significant fluctuations in the amplitude of pressure pulsations at the volute tongue were found for various initial flow rates, which correlated closely with changes in radial forces. The sudden increase and nonuniform distribution of radial forces emerged as the main factors of these fluctuations. In addition, the study reveals that the intensity of pressure fluctuations evidenced by wavelet time-frequency analysis on the pressure surface of the blade significantly exceeds that on the back surface of the blade. Furthermore, in the flow characteristics inside the draft tube, the pressure pulsation signals are mainly concentrated in the low-frequency region and are accompanied by the presence of a double-helix structure. These results provide an important reference for further understanding of the operating mechanism of the mixed-flow pump as a turbine, which helps to optimize the design and improve the performance.
- 16 August 2021
- Published by Springer Nature in Journal of Materials Science
- Vol. 56 (31) , 17694-17708
Nitrogen-doped biomass-derived porous carbon spheres for supercapacitors with ultrafast charge/discharge rate up to 2.5 V s−1
- 16 August 2021
- Published by Springer Nature in Journal of Materials Science
- Vol. 56 (31) , 17694-17708
Nitrogen-doped biomass-derived porous carbon spheres for supercapacitors with ultrafast charge/discharge rate up to 2.5 V s−1
- 19 October 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (12) , 3187-3193
Differentiating atypical hemangiomas and vertebral metastases: a field-of-view (FOV) and FOCUS intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) study
Purpose Some atypical vertebral hemangiomas (VHs) may mimic metastases on routine MRI and can result in misdiagnosis and ultimately to additional imaging, biopsy and unnecessary costs. The purpose of this study is to assess the utility of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) on account of field-of-view optimized and constrained undistorted single shot (FOCUS) in distinguishing atypical VHs and vertebral metastases. Methods A total of 25 patients with vertebral metastases and 25 patients with atypical VHs were confirmed by clinical follow-up or pathology. IVIM-DWI imaging was performed at different b values (0, 30, 50, 100, 150, 200, 400, 600, 800, 1000 mm2/s). IVIM parameters [the true diffusion coefficient (D), pseudodiffusion coefficient (D*), standard apparent diffusion coefficient (ADC), and perfusion fraction (f)] were calculated and compared between two groups by using Student’s t test. A receiver operating characteristic analysis was performed. Results Quantitative analysis of standard ADC and D parameters showed significantly lower values in vertebral metastases when compared to atypical hemangiomas [ADC value: (0.70 ± 0.12) × 10–3 mm2/s vs (1.14 ± 0.28) × 10–3 mm2/s; D value: (0.47 ± 0.07) × 10–3 mm2/s vs (0.76 ± 0.14) × 10–3 mm2/s, all P < 0.01]. The sensitivity and specificity of D value were 93.8% and 92.3%, respectively. Conclusion The standard ADC value and D value may be used as an indicator to distinguish vertebral metastases from atypical VHs. FOCUS IVIM-derived parameters provide potential value in the quantitatively differentiating vertebral metastases from vertebral atypical hemangiomas.
- 19 October 2020
- Published by Springer Nature in European Spine Journal
- Vol. 29 (12) , 3187-3193
Differentiating atypical hemangiomas and vertebral metastases: a field-of-view (FOV) and FOCUS intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) study
Purpose Some atypical vertebral hemangiomas (VHs) may mimic metastases on routine MRI and can result in misdiagnosis and ultimately to additional imaging, biopsy and unnecessary costs. The purpose of this study is to assess the utility of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) on account of field-of-view optimized and constrained undistorted single shot (FOCUS) in distinguishing atypical VHs and vertebral metastases. Methods A total of 25 patients with vertebral metastases and 25 patients with atypical VHs were confirmed by clinical follow-up or pathology. IVIM-DWI imaging was performed at different b values (0, 30, 50, 100, 150, 200, 400, 600, 800, 1000 mm2/s). IVIM parameters [the true diffusion coefficient (D), pseudodiffusion coefficient (D*), standard apparent diffusion coefficient (ADC), and perfusion fraction (f)] were calculated and compared between two groups by using Student’s t test. A receiver operating characteristic analysis was performed. Results Quantitative analysis of standard ADC and D parameters showed significantly lower values in vertebral metastases when compared to atypical hemangiomas [ADC value: (0.70 ± 0.12) × 10–3 mm2/s vs (1.14 ± 0.28) × 10–3 mm2/s; D value: (0.47 ± 0.07) × 10–3 mm2/s vs (0.76 ± 0.14) × 10–3 mm2/s, all P < 0.01]. The sensitivity and specificity of D value were 93.8% and 92.3%, respectively. Conclusion The standard ADC value and D value may be used as an indicator to distinguish vertebral metastases from atypical VHs. FOCUS IVIM-derived parameters provide potential value in the quantitatively differentiating vertebral metastases from vertebral atypical hemangiomas.
- 1 September 2018
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 280, 170-178
Mechanical properties of surface microstructures of metal dry bioelectrode
- 1 September 2018
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 280, 170-178
Mechanical properties of surface microstructures of metal dry bioelectrode
- 1 August 2017
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 263, 252-258
Characterization of impedance properties of metal dry bioelectrodes with surface microstructure arrays
- 1 August 2017
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 263, 252-258
Characterization of impedance properties of metal dry bioelectrodes with surface microstructure arrays
- Open Access
- 27 July 2005
- Published by AIP Publishing in Journal of Mathematical Physics
- Vol. 46 (8) , 083504
Nonlinear Schrödinger Equation with Inhomogeneous Dirichlet Boundary Data
In this article we study the following nonlinear Schrödinger equation iut=Δu−g∣u∣p−1u in a domain Ω⊂Rn with initial condition u(x,0)=ϕ(x) and the Dirichlet boundary condition u(x,t)=Q(x,t) on ∂Ω, where ϕ, Q are given smooth functions. The nonlinear term contributes a negative term to the energy (i.e., g<0). We present the existence theorem for a global solution of finite energy when p⩽1+2∕n.
- 27 July 2005
- Published by AIP Publishing in Journal of Mathematical Physics
- Vol. 46 (8) , 083504
Open AccessNonlinear Schrödinger Equation with Inhomogeneous Dirichlet Boundary Data
In this article we study the following nonlinear Schrödinger equation iut=Δu−g∣u∣p−1u in a domain Ω⊂Rn with initial condition u(x,0)=ϕ(x) and the Dirichlet boundary condition u(x,t)=Q(x,t) on ∂Ω, where ϕ, Q are given smooth functions. The nonlinear term contributes a negative term to the energy (i.e., g<0). We present the existence theorem for a global solution of finite energy when p⩽1+2∕n.