Carlos Gabriel
Carlos Gabriel has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin Schulz
Neuherbergstr. 109, 80937 München, Germany
1 shared publication - Cara Wilson
Information Technology and Data Services Division, Southwest Fisheries Science Center, National Marine Fisheries Service, National Oceanic and Atmospheric Administration, Monterey, CA, USA.
1 shared publication - Charles M. Telesco
Department of Astronomy University of Florida 32611 Gainesville FL USA
1 shared publication D. Lemke
Max-Planck-Institut für Astronomie, Königstuhl 17, 69117 Heidelberg, Germany
1 shared publication- David Osip
Carnegie Institution for Science
1 shared publication - Gad Levy
NorthWest Research Associates, Seattle, WA, USA
1 shared publication
Latest Publications
- 26 November 2024
- Published by Taylor & Francis in International Journal of Remote Sensing
- Vol. 45 (23) , 8673-8685
Preface: the role of space ocean science and technology towards sustainable development goal
- 26 November 2024
- Published by Taylor & Francis in International Journal of Remote Sensing
- Vol. 45 (23) , 8673-8685
Preface: the role of space ocean science and technology towards sustainable development goal
- Open Access
- 15 January 2002
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 381 (3) , 1110-1130
ISOPHOT – Photometric calibration of point sources
All observations by the aperture photometer (PHT-P) and the far-infrared (FIR) camera section of ISOPHOT included reference measurements against stable internal fine calibration sources (FCS) to correct for temporal drifts in detector responsivities. The FCSs were absolutely calibrated in-orbit against stars, asteroids and planets, covering wavelengths from 3.2 to 240 μm. We present the calibration concept for point sources within a flux-range from 60 mJy up to 4500 Jy for staring and raster observations in standard configurations and discuss the requisite measurements and the uncertainties involved. In this process we correct for instrumental effects like nonlinearities, signal transients, time variable dark current, misalignments and diffraction effects. A set of formulae is developed that describes the calibration from signal level to flux densities. The scatter of 10 to 20% of the individual data points around the derived calibration relations is a measure of the consistency and typical accuracy of the calibration. The reproducibility over longer periods of time is better than 10%. The calibration tables and algorithms have been implemented in the final versions of the software for offline processing and interactive analysis.
- 15 January 2002
- Published by EDP Sciences in Astronomy & Astrophysics
- Vol. 381 (3) , 1110-1130
Open AccessISOPHOT – Photometric calibration of point sources
All observations by the aperture photometer (PHT-P) and the far-infrared (FIR) camera section of ISOPHOT included reference measurements against stable internal fine calibration sources (FCS) to correct for temporal drifts in detector responsivities. The FCSs were absolutely calibrated in-orbit against stars, asteroids and planets, covering wavelengths from 3.2 to 240 μm. We present the calibration concept for point sources within a flux-range from 60 mJy up to 4500 Jy for staring and raster observations in standard configurations and discuss the requisite measurements and the uncertainties involved. In this process we correct for instrumental effects like nonlinearities, signal transients, time variable dark current, misalignments and diffraction effects. A set of formulae is developed that describes the calibration from signal level to flux densities. The scatter of 10 to 20% of the individual data points around the derived calibration relations is a measure of the consistency and typical accuracy of the calibration. The reproducibility over longer periods of time is better than 10%. The calibration tables and algorithms have been implemented in the final versions of the software for offline processing and interactive analysis.