Lieyi Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lieyi Dong has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Qi Wei
College of Power and Energy Engineering, Harbin Engineering University, Harbin, China
3 shared publications - Wanyou Li
Harbin Engineering University
3 shared publications Zhijun Shuai
3 shared publications- Zhijun Shuai
Harbin Engineering University
3 shared publications - Chen-Xing Jiang
College of Energy, Xiamen University, Xiamen 361102, China
2 shared publications - Depeng Zeng
College of Intelligent Systems Science and Engineering, Harbin Engineering University, Harbin, China
2 shared publications
Latest Publications
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Unsteady flow characteristics and mechanisms of a centrifugal pump with impeller translation
This study investigates the influence of impeller translation on the internal flow of a centrifugal pump, with a focus on how translation-induced effects redistribute flow structures and modulate unsteady characteristics. Non-concentric impeller motion represents a critical off-design condition that exacerbates pressure pulsations and unsteady radial forces, increasing shaft stress and the risk of fatigue failure. Therefore, it is essential for operational reliability to characterize the interplay between impeller translation and the evolution of the internal flow. A computational fluid dynamics framework for generalized impeller eccentric rotation is proposed to capture this motion, employing a vibration intensity number (VIN) to quantify different eccentric operating conditions. The radial force, outlet pressure spatiotemporal evolution, and relative velocity fields are systematically analyzed. In addition, dynamic mode decomposition (DMD) is applied to identify the corresponding frequency-domain flow features. The results demonstrate that impeller translation significantly alters the radial force and the spatiotemporal evolution of the outlet pressure. Specifically, the outlet pressure exhibits distinct low-frequency, high-pressure propagation features, whose direction, phase relation, and circumferential distribution vary with the translational state. Mechanistically, the pressure field is governed by a coupled dual effect of kinematic and dynamic influences. Under bi-directional translation, the final pressure pattern is determined by the dominant directional component when these effects are in opposition. For the VIN = 1 case, the fixed relationship between translational velocity and acceleration produces a highly ordered evolution of flow variables. The DMD results further confirm this flow reorganization in the frequency domain. In particular, impeller translation modifies the harmonics of shaft-frequency pressure modes within the impeller while inducing a strong shaft-frequency response superimposed on the stable blade-passing frequency in the volute. Overall, eccentric motion does not introduce new flow structures; instead, it reshapes the spatiotemporal organization and frequency response of the internal flow through the coupling of rotational motion with translation-induced effects. These findings provide physical insight into flow instability and vibration response under non-concentric pump operation.
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Unsteady flow characteristics and mechanisms of a centrifugal pump with impeller translation
This study investigates the influence of impeller translation on the internal flow of a centrifugal pump, with a focus on how translation-induced effects redistribute flow structures and modulate unsteady characteristics. Non-concentric impeller motion represents a critical off-design condition that exacerbates pressure pulsations and unsteady radial forces, increasing shaft stress and the risk of fatigue failure. Therefore, it is essential for operational reliability to characterize the interplay between impeller translation and the evolution of the internal flow. A computational fluid dynamics framework for generalized impeller eccentric rotation is proposed to capture this motion, employing a vibration intensity number (VIN) to quantify different eccentric operating conditions. The radial force, outlet pressure spatiotemporal evolution, and relative velocity fields are systematically analyzed. In addition, dynamic mode decomposition (DMD) is applied to identify the corresponding frequency-domain flow features. The results demonstrate that impeller translation significantly alters the radial force and the spatiotemporal evolution of the outlet pressure. Specifically, the outlet pressure exhibits distinct low-frequency, high-pressure propagation features, whose direction, phase relation, and circumferential distribution vary with the translational state. Mechanistically, the pressure field is governed by a coupled dual effect of kinematic and dynamic influences. Under bi-directional translation, the final pressure pattern is determined by the dominant directional component when these effects are in opposition. For the VIN = 1 case, the fixed relationship between translational velocity and acceleration produces a highly ordered evolution of flow variables. The DMD results further confirm this flow reorganization in the frequency domain. In particular, impeller translation modifies the harmonics of shaft-frequency pressure modes within the impeller while inducing a strong shaft-frequency response superimposed on the stable blade-passing frequency in the volute. Overall, eccentric motion does not introduce new flow structures; instead, it reshapes the spatiotemporal organization and frequency response of the internal flow through the coupling of rotational motion with translation-induced effects. These findings provide physical insight into flow instability and vibration response under non-concentric pump operation.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Effects of impeller whirling vibration on the rotor–stator interaction in a centrifugal pump
This study employs the dynamic sliding multi-region and the Reynolds averaged Navier–Stokes to conduct computational fluid dynamics numerical simulations on the centrifugal pump flow characteristics under four forms of impeller whirling vibrations. The influence mechanisms of different whirling forms on the unsteady flow characteristics and rotor–stator interaction are analyzed. Because of assembly errors and non-uniform support stiffness, the centrifugal pump impeller does not undergo simple eccentric rotation. Instead, it exhibits the complex whirling vibration with multiple kinematic characteristics, which has been neglected in previous studies. First, the numerical models of different whirling vibration forms are established to simulate the unsteady flow characteristics. The accuracy is verified using the test bench. Second, the study investigates the influence mechanisms of different whirling vibration forms on the flow characteristics and rotor–stator interaction. The results demonstrate that the rotor–stator interaction can be categorized into small-scale interaction from the single blade and large-scale interaction from the overall impeller under whirling conditions. The additional fluctuations caused by whirling vibration result from periodic variations in the magnitude and direction of the impeller outflow velocity. Under backward whirling, the modulation frequency amplitude of the flow characteristics is greater. This is because the high tangential speed region of the impeller is opposite to the whirling direction, thereby intensifying the unsteady flow characteristics caused by rotor–stator interaction. This study serves as a foundation for vibration and noise control and fault diagnosis of centrifugal pumps.
- 1 June 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (6)
Effects of impeller whirling vibration on the rotor–stator interaction in a centrifugal pump
This study employs the dynamic sliding multi-region and the Reynolds averaged Navier–Stokes to conduct computational fluid dynamics numerical simulations on the centrifugal pump flow characteristics under four forms of impeller whirling vibrations. The influence mechanisms of different whirling forms on the unsteady flow characteristics and rotor–stator interaction are analyzed. Because of assembly errors and non-uniform support stiffness, the centrifugal pump impeller does not undergo simple eccentric rotation. Instead, it exhibits the complex whirling vibration with multiple kinematic characteristics, which has been neglected in previous studies. First, the numerical models of different whirling vibration forms are established to simulate the unsteady flow characteristics. The accuracy is verified using the test bench. Second, the study investigates the influence mechanisms of different whirling vibration forms on the flow characteristics and rotor–stator interaction. The results demonstrate that the rotor–stator interaction can be categorized into small-scale interaction from the single blade and large-scale interaction from the overall impeller under whirling conditions. The additional fluctuations caused by whirling vibration result from periodic variations in the magnitude and direction of the impeller outflow velocity. Under backward whirling, the modulation frequency amplitude of the flow characteristics is greater. This is because the high tangential speed region of the impeller is opposite to the whirling direction, thereby intensifying the unsteady flow characteristics caused by rotor–stator interaction. This study serves as a foundation for vibration and noise control and fault diagnosis of centrifugal pumps.
- 21 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (9) , 1-6
Comparative Analysis of Electromagnetic Vibration and Torque Ripple of Multi-Unit PMSMs Under Normal and Fault Operation
In order to study the electromagnetic vibration and torque ripple of multi-unit permanent magnet synchronous motors (PMSMs), an analytical model of flux density under multi-unit operation was established. The spatiotemporal characteristics of 2-D air-gap flux density, electromagnetic force, and electromagnetic torque were explored, and the characteristics of electromagnetic force and vibration response under unit-missing operation were analyzed. First, the flux density analytical models under the operation of one unit and k unit motors were established, and the spatiotemporal distribution law of electromagnetic force and electromagnetic torque was analyzed. Then, the vibration response under unit-missing operation was theoretically derived and analyzed; finally, the prototype was simulated and experimentally verified. With k unit motors, the electromagnetic force and torque components exhibit harmonics with angular frequency $2\pi (2hf_{e})$ and $2\pi (6hf_{e})$ , $h\in \mathbb {N}$ , respectively ( $f_{e}$ supply line frequency). The unbalanced electromagnetic pull resulting from the lack of a single unit introduces additional force harmonics, whose frequencies differ from those in balanced operation by multiples of the rotation frequency $f_{r}=f_{e}/p$ (p: pole pairs) that, however, are not generally multiples of $f_{e}$ .
- 21 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (9) , 1-6
Comparative Analysis of Electromagnetic Vibration and Torque Ripple of Multi-Unit PMSMs Under Normal and Fault Operation
In order to study the electromagnetic vibration and torque ripple of multi-unit permanent magnet synchronous motors (PMSMs), an analytical model of flux density under multi-unit operation was established. The spatiotemporal characteristics of 2-D air-gap flux density, electromagnetic force, and electromagnetic torque were explored, and the characteristics of electromagnetic force and vibration response under unit-missing operation were analyzed. First, the flux density analytical models under the operation of one unit and k unit motors were established, and the spatiotemporal distribution law of electromagnetic force and electromagnetic torque was analyzed. Then, the vibration response under unit-missing operation was theoretically derived and analyzed; finally, the prototype was simulated and experimentally verified. With k unit motors, the electromagnetic force and torque components exhibit harmonics with angular frequency $2\pi (2hf_{e})$ and $2\pi (6hf_{e})$ , $h\in \mathbb {N}$ , respectively ( $f_{e}$ supply line frequency). The unbalanced electromagnetic pull resulting from the lack of a single unit introduces additional force harmonics, whose frequencies differ from those in balanced operation by multiples of the rotation frequency $f_{r}=f_{e}/p$ (p: pole pairs) that, however, are not generally multiples of $f_{e}$ .
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 7287-7296
High-Frequency Electromagnetic Vibration Analysis and Modulation Parameter Optimization of PMSMs Driven by Inverters
The utilization of inverters and pulse width modulation (PWM) technology in driving permanent magnet synchronous motors (PMSMs) introduces high-frequency sideband electromagnetic force. Consequently, the risk of PMSMs resonance inevitably increases, leading to disruptions in the operating state and increased noise radiation. Two-dimensional (2-D) sideband electromagnetic force, torque ripple, and electromagnetic vibration of PMSMs with integral-slot and fractional-slot winding arrangements are studied in this article. The torque ripple caused by sideband harmonic currents is derived. Rules to reduce electromagnetic vibration are proposed. The results indicate that the sideband electromagnetic forces have both low- and high-frequency characteristics. Torque ripple shows a new high-frequency characteristic. Experimental findings validate the effectiveness of the proposed rules for optimizing electromagnetic vibration, resulting in an 11.1 dB reduction in the 3.5–6.5 kHz band.
- 23 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 7287-7296
High-Frequency Electromagnetic Vibration Analysis and Modulation Parameter Optimization of PMSMs Driven by Inverters
The utilization of inverters and pulse width modulation (PWM) technology in driving permanent magnet synchronous motors (PMSMs) introduces high-frequency sideband electromagnetic force. Consequently, the risk of PMSMs resonance inevitably increases, leading to disruptions in the operating state and increased noise radiation. Two-dimensional (2-D) sideband electromagnetic force, torque ripple, and electromagnetic vibration of PMSMs with integral-slot and fractional-slot winding arrangements are studied in this article. The torque ripple caused by sideband harmonic currents is derived. Rules to reduce electromagnetic vibration are proposed. The results indicate that the sideband electromagnetic forces have both low- and high-frequency characteristics. Torque ripple shows a new high-frequency characteristic. Experimental findings validate the effectiveness of the proposed rules for optimizing electromagnetic vibration, resulting in an 11.1 dB reduction in the 3.5–6.5 kHz band.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Flow-induced vibration and heat transfer characteristics of three elliptical cylinders arranged in an isosceles triangle
This study investigates the flow-induced vibration (FIV) and heat transfer behavior of three heated cylinders arranged in an isosceles triangle configuration at a Reynolds number of 100. A dynamic model for the FIV of two-dimensional, elastically supported cylinders was developed using computational fluid dynamics simulations and overset mesh technology. The effects of aspect ratio (AR) and angle of attack (α) were examined by varying α from 30° to 90° and AR from 0.75 to 2.0, with AR = 1.0 corresponding to a circular cross section. To study FIV, the two-degree-of-freedom motion of the cylinders was analyzed across a range of reduced velocities (Ur = 2–12). The results indicate that as α increases, the impact of the upstream cylinder's wake on the downstream cylinders gradually weakens, resulting in lower vibration amplitudes and higher heat transfer rates for the downstream cylinders. Notably, when α reaches 90°, the streamwise amplitude becomes almost negligible. At α = 30° and 45°, the average Nusselt number of the downstream cylinder is generally lower than that of the upstream cylinder. However, when α reaches 60°, the average Nusselt number of the downstream cylinders becomes noticeably higher than that of the upstream cylinder. As the aspect ratio increases, the lock-in region of the cylinders shifts from being concentrated at Ur = 6 and 8 to Ur = 4 and 6, indicating that the increase in aspect ratio raises the vortex shedding frequency.
- 1 November 2024
- Published by AIP Publishing in Physics of Fluids
- Vol. 36 (11)
Flow-induced vibration and heat transfer characteristics of three elliptical cylinders arranged in an isosceles triangle
This study investigates the flow-induced vibration (FIV) and heat transfer behavior of three heated cylinders arranged in an isosceles triangle configuration at a Reynolds number of 100. A dynamic model for the FIV of two-dimensional, elastically supported cylinders was developed using computational fluid dynamics simulations and overset mesh technology. The effects of aspect ratio (AR) and angle of attack (α) were examined by varying α from 30° to 90° and AR from 0.75 to 2.0, with AR = 1.0 corresponding to a circular cross section. To study FIV, the two-degree-of-freedom motion of the cylinders was analyzed across a range of reduced velocities (Ur = 2–12). The results indicate that as α increases, the impact of the upstream cylinder's wake on the downstream cylinders gradually weakens, resulting in lower vibration amplitudes and higher heat transfer rates for the downstream cylinders. Notably, when α reaches 90°, the streamwise amplitude becomes almost negligible. At α = 30° and 45°, the average Nusselt number of the downstream cylinder is generally lower than that of the upstream cylinder. However, when α reaches 60°, the average Nusselt number of the downstream cylinders becomes noticeably higher than that of the upstream cylinder. As the aspect ratio increases, the lock-in region of the cylinders shifts from being concentrated at Ur = 6 and 8 to Ur = 4 and 6, indicating that the increase in aspect ratio raises the vortex shedding frequency.