Angela Peloso
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Angela Peloso has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Elena De Momi
Politecnico di Milano
5 shared publications - Xiu Zhang
Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Italy
5 shared publications - Anna Bicchi
Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
4 shared publications - Arianna Menciassi
The BioRobotics Institute, Scuola Superiore Sant’Anna, Pisa, Italy
3 shared publications Benjamín Ignacio Fortuño Jara
Politecnico di Milano
3 shared publications- Emiliano Votta
Politecnico di Milano
3 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (5) , 5210-5221
Collaborative Control Framework of a Robotic Transesophageal Echocardiography System for Guiding Structural Heart Interventions
Transesophageal echocardiography (TEE) is important for guiding the surgeon in percutaneous intervention for structural heart diseases. TEE is acquired through a catheterlike probe that must be maneuvered by a sonographer. Also, since X-ray fluoroscopy is adopted along with TEE, surgeons and sonographers must wear heavy protective suits to shield against radiation, leading to fatigue and the long-term risk of musculoskeletal injuries. This work proposes a robotic TEE system with a collaborative control framework designed to autonomously adjust the TEE probe, while relieving sonographers from physical effort and X-ray exposure. To enable accurate task space control in the constrained anatomical environment, a hybrid adaptive controller is introduced, leveraging offline hysteresis data and real-time feedback from electromagnetic (EM) sensors. Experiments conducted on silicone-casted esophagus phantoms with varying thicknesses, as well as path following tests with different patterns, demonstrate the controller's adaptability and accuracy. The framework was further validated through a complete workflow simulation within a cardiac phantom, replicating a transcatheter mitral valve repair procedure. The system maintained a maximum angular error below $3.2^\circ$. The results highlight the potential of the proposed robotic system for clinical applications in robot-assisted intervention procedures.
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (5) , 5210-5221
Collaborative Control Framework of a Robotic Transesophageal Echocardiography System for Guiding Structural Heart Interventions
Transesophageal echocardiography (TEE) is important for guiding the surgeon in percutaneous intervention for structural heart diseases. TEE is acquired through a catheterlike probe that must be maneuvered by a sonographer. Also, since X-ray fluoroscopy is adopted along with TEE, surgeons and sonographers must wear heavy protective suits to shield against radiation, leading to fatigue and the long-term risk of musculoskeletal injuries. This work proposes a robotic TEE system with a collaborative control framework designed to autonomously adjust the TEE probe, while relieving sonographers from physical effort and X-ray exposure. To enable accurate task space control in the constrained anatomical environment, a hybrid adaptive controller is introduced, leveraging offline hysteresis data and real-time feedback from electromagnetic (EM) sensors. Experiments conducted on silicone-casted esophagus phantoms with varying thicknesses, as well as path following tests with different patterns, demonstrate the controller's adaptability and accuracy. The framework was further validated through a complete workflow simulation within a cardiac phantom, replicating a transcatheter mitral valve repair procedure. The system maintained a maximum angular error below $3.2^\circ$. The results highlight the potential of the proposed robotic system for clinical applications in robot-assisted intervention procedures.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. PP, 1-8
A Robotic System with Path Planning and Visual Guidance for Teleoperated Left Atrial Appendage Closure
Percutaneous Left Atrial Appendage Closure (LAAC) is a minimally invasive procedure to prevent thromboembolic events in atrial fibrillation patients. The procedure's success relies on precise navigation and occluder deployment, which is challenged by sheath movement in the dynamic cardiac environment, procedural complexity, and prolonged radiation exposure. This study introduces a robotic-assisted navigation system for LAAC procedure, integrating a dedicated steerable sheath, customed planning algorithms, and an intuitive teleoperation interface. The path-planning framework generates collision-free routes based on patient-specific anatomy, adjusting for deviations in real-time. The teleoperation interface comprises a digital replica of the patient's anatomy with real-time visual feedback to the user for precise and intuitive navigation. Bench-top validation demonstrated that navigation guidance reduced target position error by $2.03\%$ with the planner and $2.85\%$ with the replanner, compared to free navigation without planning assistance. Planning and replanning strategies also reduced collisions with cardiac structures, highlighting the platform's potential to improve procedural precision and safety.
- 23 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. PP, 1-8
A Robotic System with Path Planning and Visual Guidance for Teleoperated Left Atrial Appendage Closure
Percutaneous Left Atrial Appendage Closure (LAAC) is a minimally invasive procedure to prevent thromboembolic events in atrial fibrillation patients. The procedure's success relies on precise navigation and occluder deployment, which is challenged by sheath movement in the dynamic cardiac environment, procedural complexity, and prolonged radiation exposure. This study introduces a robotic-assisted navigation system for LAAC procedure, integrating a dedicated steerable sheath, customed planning algorithms, and an intuitive teleoperation interface. The path-planning framework generates collision-free routes based on patient-specific anatomy, adjusting for deviations in real-time. The teleoperation interface comprises a digital replica of the patient's anatomy with real-time visual feedback to the user for precise and intuitive navigation. Bench-top validation demonstrated that navigation guidance reduced target position error by $2.03\%$ with the planner and $2.85\%$ with the replanner, compared to free navigation without planning assistance. Planning and replanning strategies also reduced collisions with cardiac structures, highlighting the platform's potential to improve procedural precision and safety.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (2) , 562-571
Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair
Minimally invasive mitral valve repair offers significant advantages over traditional open-heart surgery, yet it remains a complex procedure that exposes both patients and medical staff to radiation. To address these challenges, a significant research interest is growing in automating these manual procedures. Continuum robots represent a promising approach, thanks to their ability to navigate confined spaces. However, their nonlinear behavior presents challenges in modeling and control. In this study, we developed a robust position control method for a variable-length tendon-driven continuum robot. We designed a control system that effectively tracks the desired target positions by employing a constant curvature model and a Jacobian-based control algorithm with real-time position feedback. We assessed the stability of our system through Lyapunov analysis, demonstrating reliable convergence to these target positions. Experimental validation conducted in a cardiovascular phantom demonstrated significant improvements with respect to the state of the art. Our method achieved a trajectory following error of approximately 2.43 mm 1.63, 3.23 and a target position error of about 1.92 mm 1.73, 3.13. Moreover, the computation time per trajectory point was reduced to approximately 0.04 seconds, highlighting enhanced computational efficiency. These results showcase improved accuracy and efficiency in minimally invasive mitral valve repair procedures.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7 (2) , 562-571
Model-Based Position Control of a Tendon-Driven Variable-Length Continuum Robot for Minimally Invasive Mitral Valve Repair
Minimally invasive mitral valve repair offers significant advantages over traditional open-heart surgery, yet it remains a complex procedure that exposes both patients and medical staff to radiation. To address these challenges, a significant research interest is growing in automating these manual procedures. Continuum robots represent a promising approach, thanks to their ability to navigate confined spaces. However, their nonlinear behavior presents challenges in modeling and control. In this study, we developed a robust position control method for a variable-length tendon-driven continuum robot. We designed a control system that effectively tracks the desired target positions by employing a constant curvature model and a Jacobian-based control algorithm with real-time position feedback. We assessed the stability of our system through Lyapunov analysis, demonstrating reliable convergence to these target positions. Experimental validation conducted in a cardiovascular phantom demonstrated significant improvements with respect to the state of the art. Our method achieved a trajectory following error of approximately 2.43 mm 1.63, 3.23 and a target position error of about 1.92 mm 1.73, 3.13. Moreover, the computation time per trajectory point was reduced to approximately 0.04 seconds, highlighting enhanced computational efficiency. These results showcase improved accuracy and efficiency in minimally invasive mitral valve repair procedures.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (8) , 2379-2387
Imitation Learning for Path Planning in Cardiac Percutaneous Interventions
Objective: Mitral regurgitation is a valvular heart disease particularly affecting the aging population. Minimally invasive transcatheter procedures offer benefits over traditional open-chest surgery but require significant operator skill and hand-eye coordination, making the learning curve steeper and limiting accessibility. To address these challenges, there is growing research interest in automating these procedures, making it crucial to define safe navigable routes within anatomical structures for robotic operation. This study introduces a tailored learning-based framework for path planning in cardiac percutaneous interventions, specifically adapted to the dynamically constrained and safety-critical environment of mitral valve repair. Methods: We compared generative adversarial imitation learning and behavioral cloning techniques to traditional path planning algorithms like rapidly-exploring random trees. Using patient-specific anatomical data, a faithful digital twin was created, with dynamic motions to replicate real-time cardiac movements of the mitral valve. Results: Learning approaches significantly reduced target position errors and improved path smoothness with greater clearance from obstacles compared to state-of-the-art methods. Conclusion: Learning methodologies provided consistent and repeatable routes in cardiac anatomy, both in pre-operative static and intra-operative dynamic scenarios. Significance: Embedding task demonstrations in the learning process shows the potential to automate and optimize catheter navigation, promoting standardization of minimally invasive cardiac procedures.
- 13 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (8) , 2379-2387
Imitation Learning for Path Planning in Cardiac Percutaneous Interventions
Objective: Mitral regurgitation is a valvular heart disease particularly affecting the aging population. Minimally invasive transcatheter procedures offer benefits over traditional open-chest surgery but require significant operator skill and hand-eye coordination, making the learning curve steeper and limiting accessibility. To address these challenges, there is growing research interest in automating these procedures, making it crucial to define safe navigable routes within anatomical structures for robotic operation. This study introduces a tailored learning-based framework for path planning in cardiac percutaneous interventions, specifically adapted to the dynamically constrained and safety-critical environment of mitral valve repair. Methods: We compared generative adversarial imitation learning and behavioral cloning techniques to traditional path planning algorithms like rapidly-exploring random trees. Using patient-specific anatomical data, a faithful digital twin was created, with dynamic motions to replicate real-time cardiac movements of the mitral valve. Results: Learning approaches significantly reduced target position errors and improved path smoothness with greater clearance from obstacles compared to state-of-the-art methods. Conclusion: Learning methodologies provided consistent and repeatable routes in cardiac anatomy, both in pre-operative static and intra-operative dynamic scenarios. Significance: Embedding task demonstrations in the learning process shows the potential to automate and optimize catheter navigation, promoting standardization of minimally invasive cardiac procedures.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (1) , 104-111
Design and Hysteresis Compensation of a Telerobotic System for Transesophageal Echocardiography
Transesophageal echocardiogram (TEE) plays an important role in diagnosing cardiac conditions such as valvular diseases and cardiac embolism, as well as guiding various cardiac interventions. It provides detailed cardiac imaging by inserting a probe into the esophagus, which offers an unobstructed view of the heart's chambers and valves. Addressing the operational challenges and health risks of the sonographer associated with the manual procedure, a novel robotic TEE system is developed to teleoperate the TEE probe across all four degrees of freedom (4-DoFs). This actuation device features an easily assembled design for post-operative cleaning and sanitization. Moreover, this system enhances the precision of tip bending angles through an optimization technique for offline calibration of the actuation plane. The hysteresis effect inherent in the tendon-driven mechanism is characterized and compensated using a free knots B-spline method and a look-up table. Experiments are conducted in a realistic human cardiovascular phantom for preclinical evaluation. Repeatability experiments validate the system's robustness. Furthermore, compared with the piecewise linear model, the proposed method achieves high accuracy with a median bending angle error of less than $\mathbf {0.8^\circ }$ . The results demonstrate the system's potential to significantly improve the autonomy of TEE procedures in cardiac diagnostic and therapeutic procedures.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 10 (1) , 104-111
Design and Hysteresis Compensation of a Telerobotic System for Transesophageal Echocardiography
Transesophageal echocardiogram (TEE) plays an important role in diagnosing cardiac conditions such as valvular diseases and cardiac embolism, as well as guiding various cardiac interventions. It provides detailed cardiac imaging by inserting a probe into the esophagus, which offers an unobstructed view of the heart's chambers and valves. Addressing the operational challenges and health risks of the sonographer associated with the manual procedure, a novel robotic TEE system is developed to teleoperate the TEE probe across all four degrees of freedom (4-DoFs). This actuation device features an easily assembled design for post-operative cleaning and sanitization. Moreover, this system enhances the precision of tip bending angles through an optimization technique for offline calibration of the actuation plane. The hysteresis effect inherent in the tendon-driven mechanism is characterized and compensated using a free knots B-spline method and a look-up table. Experiments are conducted in a realistic human cardiovascular phantom for preclinical evaluation. Repeatability experiments validate the system's robustness. Furthermore, compared with the piecewise linear model, the proposed method achieves high accuracy with a median bending angle error of less than $\mathbf {0.8^\circ }$ . The results demonstrate the system's potential to significantly improve the autonomy of TEE procedures in cardiac diagnostic and therapeutic procedures.