ABAmélie Bourgeois

Amélie Bourgeois

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amélie Bourgeois has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Antoine Remy

    Bio-, Electro- and Mechanical- Systems (BEAMS), Biomed Group, Ecole Polytechnique de Bruxelles, Brussels, Belgium

    2 shared publications
  • Teo Serra

    Bio-, Electro- and Mechanical- Systems (BEAMS), Biomed Group, Ecole Polytechnique de Bruxelles, Brussels, Belgium

    2 shared publications
  • Alain Delchambre

    Bio-, Electro- and Mechanical- Systems (BEAMS), Biomed Group, Ecole Polytechnique de Bruxelles, Brussels, Belgium

    1 shared publication
  • Anne Botteaux

    Laboratory of Microbiology, European Plotkin Institute for Vaccinology (EPIV), Université Libre de Bruxelles (ULB), Faculty of Medicine, Brussels, Belgium

    1 shared publication
  • Antoine Nonclercq

    Bio-, Electro- and Mechanical- Systems (BEAMS), Biomed Group, Ecole Polytechnique de Bruxelles, Brussels, Belgium

    1 shared publication
  • Arnaud Lemmers

    Laboratory of Experimental Gastroenterology, Université Libre de Bruxelles (ULB), Faculty of Medicine, Brussels, Belgium

    1 shared publication

Latest Publications

  • Comparison of direct and transferred cold atmospheric discharge in long, flexible tubes for the decontamination and removal of Pseudomonas aeruginosa biofilms

    by Antoine Remy, Juliette Zveny, Teo Serra, Amélie Bourgeois, Orianne Bastin, Dalila Lakhloufi, Arnaud Lemmers, Anne Botteaux, Alain Delchambre, Francois Reniers, et al.

    Endoscope working channels are particularly vulnerable to bacterial contamination and biofilm formation due to repeated exposure to biological fluids and limited sterilization options. Inadequate reprocessing can lead to the formation of persistent biofilms and the transmission of healthcare-associated infections. To address this, we investigate the use of cold atmospheric plasma (CAP) generated directly inside endoscope-like Polytetrafluoroethylene (PTFE) tubing to improve decontamination and biofilm removal. This study compares two dielectric barrier discharge (DBD) configurations: a one discharge tube (ODT), in which the plasma is generated directly inside the contaminated tube, and a two discharge tube (TDT), where a high-power upstream discharge supplies reactive species to a second discharge within the tube, also called transferred discharges. Both systems were evaluated using 2 cm samples of PTFE tube colonized with Pseudomonas aeruginosa biofilms, using the Pineau-Alfa model. Several gases or gas mixtures (He, Ar, He/O 2 , Ar/H 2 O, He/H 2 O, and air) were tested. The discharges were characterized using electrical measurements, optical emission spectroscopy, Fourier transform infrared spectroscopy FTIR, and H 2 O 2 quantification to analyze the production of reactive oxygen and nitrogen species (RONS). All gas conditions except TDT–air achieved full bacterial decontamination within 5 min. However, biofilm removal was limited, with the most effective condition (ODT–He/H 2 O) reducing biofilm coverage on the surface by 29 ± 6%. The ODT configuration provided superior local RONS delivery, including atomic oxygen and OH radicals. Its simpler design and the direct contact of the discharge with the contaminated surfaces present significant advantages for implementation in clinical settings, while maintaining the same decontamination capabilities. These findings confirm the feasibility of CAP-based in-situ decontamination for long, flexible medical tubing. Further optimization of discharge parameters and treatment time is required to enhance biofilm removal and achieve single-step, residue-free reprocessing of endoscopic devices while eliminating the reliance on hazardous chemicals (e.g. ethylene oxide, glutaraldehyde) or disposable endoscopes.

  • Pseudomonas aeruginosa biofilm decontamination and removal by Ar/H2O cold atmospheric plasma in endoscope-like tubing

    by Remy Antoine, Zveny Juliette, Serra Teo, Lakhloufi Dalila, Bourgeois Amélie, Devière Jacques, Botteaux Anne, Delchambre Alain, Reniers François, Nonclercq Antoine

    In medical device disinfection, removing bacteria and biofilms is challenging due to the poor penetration of detergents into the biofilm matrix. This is specifically true for endoscopes, which cannot be fully sterilized. This paper presents a new technique for decontaminating and removing P. aeruginosa biofilm from endoscope tubing using cold atmospheric plasma (CAP). The CAP is produced everywhere inside a contaminated tube under sustained Ar/H2O flow. The tube arrangement mimics the working channel environment of an endoscope, which is particularly difficult to sterilize. The discharge’s chemical activity was optimized by increasing the voltage without increasing the total power, which enhanced the production of hydroxyl radicals (OH) and hydrogen peroxide (H2O2). The disinfection treatment was tested on 24 h grown biofilm using the crystal violet assay for biofilm removal and the regrowth assay for bacterial decontamination. The treatments demonstrated effective decontamination capabilities at all treatment times with no bacterial regrowth. Etching of the biofilm sample by OH radicals was observed. After 30 min of treatment, only 18 ± 4% of biofilm remained on the surface, indicating near-complete biofilm removal and total absence of bacterial regrowth. This preliminary study demonstrates the effectiveness of using the direct contact of an Ar/H2O plasma to decontaminate and remove biofilm from complex shapes, such as flexible polytetraethylene tubes. It has the potential to enhance and shorten the disinfection of medical equipment, such as endoscopes.