Heng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Heng Liu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Liran Shen
State Key Laboratory of Industrial Control Technology, College of Control Science and Engineering, Zhejiang University, Hangzhou, China
5 shared publications - Yuqi Cao
State Key Laboratory of Industrial Control Technology, College of Control Science and Engineering, Zhejiang University, Hangzhou, China
5 shared publications - Guangxin Zhang
Department of Thoracic Surgery, The Second Hospital of Jilin University
4 shared publications - Liangfei Tian
Department of Ambulatory Surgery Women's Hospital School of Medicine Zhejiang University Hangzhou 310027 China
4 shared publications Yi Zhang
TROE Photonics, Hangzhou, Ltd., China
4 shared publications- Dibo Hou
Zhejiang University
3 shared publications
Latest Publications
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (6) , 2237-2244
High Sensitivity Sensor Based on Bound State in the Continuum in Detection for Cancer Cells
Although terahertz (THz) metasurfaces based on bound state in the continuum (BIC) have garnered significant attention in biomedical applications, their technical implementation in high-sensitivity cancer cells detection remains a critical challenge. In this work, we present a THz biosensor employing dual split-ring resonator (DSRR) arrays based on quasi-bound state in the continuum (Q-BIC). Numerical simulations reveal a high-Q resonance dip at 2.35 THz with a detection sensitivity of 522 GHz/RIU. Experimentally, the performance was validated by detecting normal cells (murine splenocytes) and three cancer cell lines (LLC, LoVo, and MC38). In addition, analysis of cell type discrimination was achieved by integrating machine learning algorithms to project high-dimensional spectral data into a low-dimensional space. This study establishes a label-free approach for long-term cellular monitoring, advancing THz technology as an innovative platform for practical biomedical applications.
- 31 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (6) , 2237-2244
High Sensitivity Sensor Based on Bound State in the Continuum in Detection for Cancer Cells
Although terahertz (THz) metasurfaces based on bound state in the continuum (BIC) have garnered significant attention in biomedical applications, their technical implementation in high-sensitivity cancer cells detection remains a critical challenge. In this work, we present a THz biosensor employing dual split-ring resonator (DSRR) arrays based on quasi-bound state in the continuum (Q-BIC). Numerical simulations reveal a high-Q resonance dip at 2.35 THz with a detection sensitivity of 522 GHz/RIU. Experimentally, the performance was validated by detecting normal cells (murine splenocytes) and three cancer cell lines (LLC, LoVo, and MC38). In addition, analysis of cell type discrimination was achieved by integrating machine learning algorithms to project high-dimensional spectral data into a low-dimensional space. This study establishes a label-free approach for long-term cellular monitoring, advancing THz technology as an innovative platform for practical biomedical applications.
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (12) , 21455-21463
Polarization-Insensitive Terahertz Biosensing Method Based on Toroidal Dipole Metasurface
Terahertz (THz) metasurfaces based on toroidal dipoles exhibit significant potential in biosensing applications. This study presents a polarization-insensitive THz metasurface biosensor designed with a fourfold rotationally symmetric toroidal dipole structure, consisting of a circular ring and four split-ring resonators. By exploiting the low-loss and polarization-insensitive properties of toroidal dipoles, the proposed sensor achieves significant electromagnetic field magnification and high sensitivity of biomolecular detection in the THz regime. Numerical simulation demonstrates a refractive index sensitivity of 721 GHz/RIU, while experimental measurements of cell suspensions indicate a sensitivity of 400 kHz/(cell/mL). The polarization-insensitive response, analyzed through multipole decomposition theory, is attributed to the balanced electromagnetic characteristics of the structure, which ensures consistent excitation of toroidal dipoles and magnetic quadrupoles across different polarization angles. For quantitative analysis, partial least squares (PLS) and support vector regression (SVR) methods are utilized to analyze liver cell lines (HepG2 and Miha), achieving high predictive accuracy with a mean squared error of 0.083. This work circumvents the polarization dependence observed in conventional THz biosensors and proposes an innovative approach for developing high-performance biosensing devices.
- 5 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (12) , 21455-21463
Polarization-Insensitive Terahertz Biosensing Method Based on Toroidal Dipole Metasurface
Terahertz (THz) metasurfaces based on toroidal dipoles exhibit significant potential in biosensing applications. This study presents a polarization-insensitive THz metasurface biosensor designed with a fourfold rotationally symmetric toroidal dipole structure, consisting of a circular ring and four split-ring resonators. By exploiting the low-loss and polarization-insensitive properties of toroidal dipoles, the proposed sensor achieves significant electromagnetic field magnification and high sensitivity of biomolecular detection in the THz regime. Numerical simulation demonstrates a refractive index sensitivity of 721 GHz/RIU, while experimental measurements of cell suspensions indicate a sensitivity of 400 kHz/(cell/mL). The polarization-insensitive response, analyzed through multipole decomposition theory, is attributed to the balanced electromagnetic characteristics of the structure, which ensures consistent excitation of toroidal dipoles and magnetic quadrupoles across different polarization angles. For quantitative analysis, partial least squares (PLS) and support vector regression (SVR) methods are utilized to analyze liver cell lines (HepG2 and Miha), achieving high predictive accuracy with a mean squared error of 0.083. This work circumvents the polarization dependence observed in conventional THz biosensors and proposes an innovative approach for developing high-performance biosensing devices.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10984-10991
Label-Free Detection of Biological Cells Using Quasi-Bound States in the Continuum With Terahertz Metasurface
Terahertz (THz) biosensors as an advanced approach for non-destructive, label-free, and long-term monitoring of cellular states, hold tremendous potential in early disease screening and cellular drug sensitivity testing. This paper presents a THz metasurface composed of two semi-circular split-ring resonators based on quasi-bound states in the continuum (Q-BIC) mechanism. The localized field enhancement of the Q-BIC structure can significantly boost strong light-matter interactions, enabling highly sensitive detection of biological analytes. The sensitivity of the presented biosensor reaches as high as 517 GHz/RIU. Via resonance frequency shifts, we achieve ultrasensitive distinguishment between different concentrations of cancer cells (HepG2) and normal cells (293T). The results demonstrate that, without the need for additional factors, the frequency shift of the Q-BIC resonance can successfully identify different types of biological cells of varying cell concentrations. The experimental sensitivity reaches up to 456.64 kHz/(cell mL-1), with a detection limit of 5×103 cells/mL, confirming the feasibility of the designed structure. The QBIC-based THz biosensor exhibits significant potential in distinguishing different biological cells and detecting low-concentration cells, paving a new path for ultra-sensitive biomedical detection.
- 26 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10984-10991
Label-Free Detection of Biological Cells Using Quasi-Bound States in the Continuum With Terahertz Metasurface
Terahertz (THz) biosensors as an advanced approach for non-destructive, label-free, and long-term monitoring of cellular states, hold tremendous potential in early disease screening and cellular drug sensitivity testing. This paper presents a THz metasurface composed of two semi-circular split-ring resonators based on quasi-bound states in the continuum (Q-BIC) mechanism. The localized field enhancement of the Q-BIC structure can significantly boost strong light-matter interactions, enabling highly sensitive detection of biological analytes. The sensitivity of the presented biosensor reaches as high as 517 GHz/RIU. Via resonance frequency shifts, we achieve ultrasensitive distinguishment between different concentrations of cancer cells (HepG2) and normal cells (293T). The results demonstrate that, without the need for additional factors, the frequency shift of the Q-BIC resonance can successfully identify different types of biological cells of varying cell concentrations. The experimental sensitivity reaches up to 456.64 kHz/(cell mL-1), with a detection limit of 5×103 cells/mL, confirming the feasibility of the designed structure. The QBIC-based THz biosensor exhibits significant potential in distinguishing different biological cells and detecting low-concentration cells, paving a new path for ultra-sensitive biomedical detection.
- 12 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 15 (1) , 28-36
Ultrasensitive Terahertz Biodetection Using Metasensors Based on Parity-Time Symmetry
Terahertz (THz) spectroscopy has unique sensing capabilities for biological cells due to its high temporal resolution and label-free characteristics. By combining THz technologies with the local enhancement effects of the electric field induced by the metasurface, high sensitivity detection of biological analytes can be achieved. In this work, an ultrasensitive THz metasurface biosensor based on Parity-time (PT) symmetry is proposed. Consisting of a cut wire and a pair of split ring resonators, the exceptional point structure in PT symmetry can realize a balance between the gain and the loss, which leads to a high detection sensitivity. The simulation shows that the proposed biosensor can reach a sensitivity as high as 584 GHz/RIU at the exceptional point with polarization-insensitive stability across a ±35° angle range. Experimentally, the biosensor achieves a sensitivity up to 1030.51 kHz/ (cell/mL-1) in detecting different biological cells. Principal component analysis is used to reduce the dimensionality of features composed of frequency shifts and peak amplitudes. A random forest model is then used to classify the processed features and achieves a 98.9% identification accuracy. The proposed biosensor demonstrates capabilities of highly sensitive detection of cancer cells, providing an effective and rapid method for early cancer screening, grading, and staging.
- 12 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Terahertz Science and Technology
- Vol. 15 (1) , 28-36
Ultrasensitive Terahertz Biodetection Using Metasensors Based on Parity-Time Symmetry
Terahertz (THz) spectroscopy has unique sensing capabilities for biological cells due to its high temporal resolution and label-free characteristics. By combining THz technologies with the local enhancement effects of the electric field induced by the metasurface, high sensitivity detection of biological analytes can be achieved. In this work, an ultrasensitive THz metasurface biosensor based on Parity-time (PT) symmetry is proposed. Consisting of a cut wire and a pair of split ring resonators, the exceptional point structure in PT symmetry can realize a balance between the gain and the loss, which leads to a high detection sensitivity. The simulation shows that the proposed biosensor can reach a sensitivity as high as 584 GHz/RIU at the exceptional point with polarization-insensitive stability across a ±35° angle range. Experimentally, the biosensor achieves a sensitivity up to 1030.51 kHz/ (cell/mL-1) in detecting different biological cells. Principal component analysis is used to reduce the dimensionality of features composed of frequency shifts and peak amplitudes. A random forest model is then used to classify the processed features and achieves a 98.9% identification accuracy. The proposed biosensor demonstrates capabilities of highly sensitive detection of cancer cells, providing an effective and rapid method for early cancer screening, grading, and staging.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10006-10014
Characterization of High Sensitivity Terahertz Metasurface Resonance With Application to Tumor Cell Detection
Terahertz (THz) metasurface produces distinctive resonance peaks that possess exceptional sensing properties for biological cells, achieving label-free, high-time resolution, and ultrasensitive detection. Thus, this study proposes a bright-bright mode electromagnetically induced transparency (EIT) like THz biosensor through the fusion of resonant peaks, which is combined with an E-type and inverse C-type mode. The coupling of these two bright modes results in destructive interference of the electromagnetic field at 2.15 THz, forming an EIT window. The Fabry–Perot interference principle was employed to calculate the transmission coefficient of the resonance layer. Moreover, the optimized structure was proposed based on the circuit damping factor and resonance frequency distribution. Consequently, diverse types of tumor cells were measured in this study, the sensitivity of two resonance peak reached 434 and 548 GHz/RIU. Specifically, detection sensitivity of lung cancer-cell can reach 920 kHz/cell/mL, indicating that the EIT-like THz biosensor based on the bright-bright mode can significantly contribute to early cancer diagnosis.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (7) , 10006-10014
Characterization of High Sensitivity Terahertz Metasurface Resonance With Application to Tumor Cell Detection
Terahertz (THz) metasurface produces distinctive resonance peaks that possess exceptional sensing properties for biological cells, achieving label-free, high-time resolution, and ultrasensitive detection. Thus, this study proposes a bright-bright mode electromagnetically induced transparency (EIT) like THz biosensor through the fusion of resonant peaks, which is combined with an E-type and inverse C-type mode. The coupling of these two bright modes results in destructive interference of the electromagnetic field at 2.15 THz, forming an EIT window. The Fabry–Perot interference principle was employed to calculate the transmission coefficient of the resonance layer. Moreover, the optimized structure was proposed based on the circuit damping factor and resonance frequency distribution. Consequently, diverse types of tumor cells were measured in this study, the sensitivity of two resonance peak reached 434 and 548 GHz/RIU. Specifically, detection sensitivity of lung cancer-cell can reach 920 kHz/cell/mL, indicating that the EIT-like THz biosensor based on the bright-bright mode can significantly contribute to early cancer diagnosis.
- Open Access
- 1 February 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2206 (1) , 012002
Numerical Simulation of Hydrofoil Cavitation
A contrastive analysis was conducted on the lift and drag performance, pressure and gas-phase volume fraction of NACA4412 hydrofoil under different conditions of the cavitation number and the angle of attack based on CFD. The results are obtained as follows: after hydrofoil cavitation, the lift coefficient decreased and the drag coefficient increased with the decrease of the cavitation number, and supercavitation can reduce the drag coefficient locally; the pressure difference between the upper and lower surfaces of the hydrofoil decreased and the cavitation zone on the upper surface became larger with the decrease of the cavitation number; the cavitation zone of the hydrofoil originated from the leading edge; the length of the cavitation zone under large cavitation numbers first increased and then decreased with the increase of the angle of attack, and the zone moved towards the leading edge; the cavitation zone under small cavitation numbers covered almost the entire upper surface of the hydrofoil.
- 1 February 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2206 (1) , 012002
Open AccessNumerical Simulation of Hydrofoil Cavitation
A contrastive analysis was conducted on the lift and drag performance, pressure and gas-phase volume fraction of NACA4412 hydrofoil under different conditions of the cavitation number and the angle of attack based on CFD. The results are obtained as follows: after hydrofoil cavitation, the lift coefficient decreased and the drag coefficient increased with the decrease of the cavitation number, and supercavitation can reduce the drag coefficient locally; the pressure difference between the upper and lower surfaces of the hydrofoil decreased and the cavitation zone on the upper surface became larger with the decrease of the cavitation number; the cavitation zone of the hydrofoil originated from the leading edge; the length of the cavitation zone under large cavitation numbers first increased and then decreased with the increase of the angle of attack, and the zone moved towards the leading edge; the cavitation zone under small cavitation numbers covered almost the entire upper surface of the hydrofoil.