Nicholas M. Remillard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nicholas M. Remillard has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Bruce M. Damon
Carle Clinical Imaging Research Program Stephens Family Clinical Research Institute, Carle Health Urbana Illinois USA
1 shared publication Gwenael Layec
Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA, USA
1 shared publication- Jane A. Kent
Department of Kinesiology, University of Massachusetts at Amherst, Amherst, Massachusetts, United States
1 shared publication - John R. Sirard
Department of Kinesiology, University of Massachusetts Amherst, Amherst, MA, USA
1 shared publication Joseph Gordon
1 shared publication- Luke R. Arieta
University of Massachusetts Amherst, Amherst, MA, USA
1 shared publication
Latest Publications
- 1 January 2026
- Published by Human Kinetics in Journal for the Measurement of Physical Behaviour
- Vol. 9 (1)
Responsiveness of Hip and Wrist Accelerometer-Based Physical Activity Estimates in Youth
Interventions that target physical activity (PA) typically test change between time points, often using accelerometer-based wearable activity monitors. However, only a few accelerometer-based methods have been tested for their ability to detect change over time, a measurement property known as responsiveness. Purpose : To determine the responsiveness of accelerometer-based methods, compared with a criterion measure, when predicting PA intensity in youth. Methods : Forty-seven participants (11.8 ± 3.3 years, 22 males) completed two 2-hr free-living visits. Throughout each visit, participants wore a portable indirect calorimeter (Cosmed K4b 2 or K5) and three ActiGraph GT9X devices (right wrist, left wrist, and right hip). Three hip-based and seven wrist-based methods were used to estimate time spent in sedentary behavior (≤1.50 youth metabolic equivalents [MET y ]), light PA (1.51–2.99 MET y ), and moderate to vigorous PA (≥3.00 MET y ) for each visit. Estimated MET y -minutes were calculated from regression-based methods. To assess responsiveness, visit-to-visit change scores in each variable were calculated and compared against indirect calorimetry using tests of group-level agreement (mean bias and 95% confidence intervals) and individual-level agreement (correlation plots and R 2 values). Results : When assessing mean bias of visit-to-visit change estimates, all confidence intervals spanned zero for sedentary behavior, light PA, and MET y -minutes (mean bias ± SD , sedentary behavior: 1.1 ± 1.7 min, light PA: −0.3 ± 2.9 min, MET y -minutes: 0.4 ± 7.1 min). For moderate to vigorous PA, three methods’ biases failed to cross zero (−0.8 ± 3.3 min). Large individual variability drove the nonsignificant group-level differences, as demonstrated by the correlation plots, with R 2 ranging from .14 to .73. Conclusions : Accelerometer-based PA estimates show acceptable responsiveness at the group level, but are highly variable at the individual level.
- 1 January 2026
- Published by Human Kinetics in Journal for the Measurement of Physical Behaviour
- Vol. 9 (1)
Responsiveness of Hip and Wrist Accelerometer-Based Physical Activity Estimates in Youth
Interventions that target physical activity (PA) typically test change between time points, often using accelerometer-based wearable activity monitors. However, only a few accelerometer-based methods have been tested for their ability to detect change over time, a measurement property known as responsiveness. Purpose : To determine the responsiveness of accelerometer-based methods, compared with a criterion measure, when predicting PA intensity in youth. Methods : Forty-seven participants (11.8 ± 3.3 years, 22 males) completed two 2-hr free-living visits. Throughout each visit, participants wore a portable indirect calorimeter (Cosmed K4b 2 or K5) and three ActiGraph GT9X devices (right wrist, left wrist, and right hip). Three hip-based and seven wrist-based methods were used to estimate time spent in sedentary behavior (≤1.50 youth metabolic equivalents [MET y ]), light PA (1.51–2.99 MET y ), and moderate to vigorous PA (≥3.00 MET y ) for each visit. Estimated MET y -minutes were calculated from regression-based methods. To assess responsiveness, visit-to-visit change scores in each variable were calculated and compared against indirect calorimetry using tests of group-level agreement (mean bias and 95% confidence intervals) and individual-level agreement (correlation plots and R 2 values). Results : When assessing mean bias of visit-to-visit change estimates, all confidence intervals spanned zero for sedentary behavior, light PA, and MET y -minutes (mean bias ± SD , sedentary behavior: 1.1 ± 1.7 min, light PA: −0.3 ± 2.9 min, MET y -minutes: 0.4 ± 7.1 min). For moderate to vigorous PA, three methods’ biases failed to cross zero (−0.8 ± 3.3 min). Large individual variability drove the nonsignificant group-level differences, as demonstrated by the correlation plots, with R 2 ranging from .14 to .73. Conclusions : Accelerometer-based PA estimates show acceptable responsiveness at the group level, but are highly variable at the individual level.
- 1 January 2024
- Published by Human Kinetics in Journal for the Measurement of Physical Behaviour
- Vol. 7 (1)
Validation of Exercise and Postexercise Energy Expenditure Estimates Using Hip and Wrist Accelerometer Algorithms
To estimate physical activity intensity, accelerometer-based devices are often calibrated to energy expenditure (EE) measures using indirect calorimetry (IC). Most EE estimation algorithms are based on steady-state data and do not consider excess postexercise oxygen consumption (EPOC). Purpose: The purpose of this study is to determine the effect of incorporating EPOC into linear and nonlinear accelerometer methods for estimating EE after high-intensity running. Methods: Nine adult males participated in three visits using IC to measure EE while wearing wrist and hip ActiGraph accelerometers. Each visit is described as follows: (a) Visit 1: a treadmill VO2peak test determined treadmill speed for subsequent visits; (b) Visit 2: 20-min seated baseline and three vigorous treadmill running bouts (30, 60, and 120 s) with 20-min seated rest between; and (c) Visit 3: 60-min supine baseline and a 30-min treadmill run followed by 3-hr supine rest. Fifteen EE estimation algorithms were compared with IC-measured EE. The bias (ActiGraph accelerometers − IC) and 95% confidence interval of the bias were used to determine significance. Results: Linear regression EE algorithms tended to overestimate EE after each exercise bout (mean bias kilocalories [95% confidence intervals]; 30 s: 12.5 [3.3, 21.6], 60 s: 9.6 [0.4, 18.9], 120 s: 6.5 [−2.7, 15.7], and 30 min: 177.5 [84.6, 262.1]). The nonlinear algorithms underestimated EE after the short bouts and, due to the wide confidence interval, demonstrated no bias after the 30-min bout (30 s: −7.9 [−10.2, −5.6], 60 s: −10.9 [−14.0, −7.9], 120 s: −15.4 [−15.9, −14.8], 30 min: 14.8[−39.5, 69.2]). Adding EPOC did not improve EE estimates. Conclusions: Generally, the addition of measured EPOC did not improve device-based EE estimates. Nonlinear methods demonstrated less bias in estimating postexercise EE than linear methods.
- 1 January 2024
- Published by Human Kinetics in Journal for the Measurement of Physical Behaviour
- Vol. 7 (1)
Validation of Exercise and Postexercise Energy Expenditure Estimates Using Hip and Wrist Accelerometer Algorithms
To estimate physical activity intensity, accelerometer-based devices are often calibrated to energy expenditure (EE) measures using indirect calorimetry (IC). Most EE estimation algorithms are based on steady-state data and do not consider excess postexercise oxygen consumption (EPOC). Purpose: The purpose of this study is to determine the effect of incorporating EPOC into linear and nonlinear accelerometer methods for estimating EE after high-intensity running. Methods: Nine adult males participated in three visits using IC to measure EE while wearing wrist and hip ActiGraph accelerometers. Each visit is described as follows: (a) Visit 1: a treadmill VO2peak test determined treadmill speed for subsequent visits; (b) Visit 2: 20-min seated baseline and three vigorous treadmill running bouts (30, 60, and 120 s) with 20-min seated rest between; and (c) Visit 3: 60-min supine baseline and a 30-min treadmill run followed by 3-hr supine rest. Fifteen EE estimation algorithms were compared with IC-measured EE. The bias (ActiGraph accelerometers − IC) and 95% confidence interval of the bias were used to determine significance. Results: Linear regression EE algorithms tended to overestimate EE after each exercise bout (mean bias kilocalories [95% confidence intervals]; 30 s: 12.5 [3.3, 21.6], 60 s: 9.6 [0.4, 18.9], 120 s: 6.5 [−2.7, 15.7], and 30 min: 177.5 [84.6, 262.1]). The nonlinear algorithms underestimated EE after the short bouts and, due to the wide confidence interval, demonstrated no bias after the 30-min bout (30 s: −7.9 [−10.2, −5.6], 60 s: −10.9 [−14.0, −7.9], 120 s: −15.4 [−15.9, −14.8], 30 min: 14.8[−39.5, 69.2]). Adding EPOC did not improve EE estimates. Conclusions: Generally, the addition of measured EPOC did not improve device-based EE estimates. Nonlinear methods demonstrated less bias in estimating postexercise EE than linear methods.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Relationships Between Muscle Function, Muscle Fat, and Architecture Measured by MRI in Vivo
The purpose of this work was to investigate the associations between skeletal muscle function and markers of fat content, diffusivity, and architecture. Combining MR techniques that measure muscle structure in vivo with muscle strength measures can elucidate mechanisms other than muscle size that may contribute to functional impairments. This study identified variables (e.g., fascicle length, muscle curvature, pennation angle, fat fraction) that are worthy of investigation in conjunction with functional parameters in future research, and highlighted assessment of muscle function across various contraction types and velocities.
- 3 August 2023
- Published by International Society for Magnetic Resonance in Medicine (ISMRM)
Relationships Between Muscle Function, Muscle Fat, and Architecture Measured by MRI in Vivo
The purpose of this work was to investigate the associations between skeletal muscle function and markers of fat content, diffusivity, and architecture. Combining MR techniques that measure muscle structure in vivo with muscle strength measures can elucidate mechanisms other than muscle size that may contribute to functional impairments. This study identified variables (e.g., fascicle length, muscle curvature, pennation angle, fat fraction) that are worthy of investigation in conjunction with functional parameters in future research, and highlighted assessment of muscle function across various contraction types and velocities.