Tanawat Tawonwong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tanawat Tawonwong has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Ratanaporn Toengkhuntod
Faculty of Medicine Ramathibodi Hospital, Mahidol University, Thailand
1 shared publication- Sasithorn Amnuaywattakorn
Faculty of Medicine Ramathibodi Hospital Department of Diagnostic and Therapeutic Radiology Division of Nuclear Medicine Mahidol University Thailand Bangkok
1 shared publication Sasivimol Promma
Faculty of Medicine Ramathibodi Hospital, Mahidol University, Thailand
1 shared publicationSuchawadee Musikarat
Faculty of Medicine Ramathibodi Hospital, Mahidol University, Thailand
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by Chiang Mai University in Biomedical Sciences and Clinical Medicine
- Vol. 63 (1) , 8-13
The Precision of Lumbar Spine BMD and TBS on Different Vertebral Combinations
OBJECTIVE The objective of this study is to compute the precision and LSC of BMD and TBS at the lumbar spine using dual-energy X-ray absorptiometry in different vertebral combinations. METHODS Thirty female participants (age 58.8 ± 4.0 years, height: 155.0 ± 5.2 cm, weight: 57.4 ± 8.6 kg and BMI: 23.9 ± 3.6) were scanned at the lumbar spine twice in the same day using DXA. The precision and LSC of BMD and TBS were computed in terms of the RMS-SD and %CV using the ISCD Advanced Precision Calculation Tool. RESULTS The precision and LSC of BMD of the 4 vertebrae combinations showed the best precision and also showed a similar trend (0.005 g/cm2 and 0.62%, 0.013 g/cm2 and 1.71%), respectively. For TBS, the precision and LSC followed a similar pattern as BMD but was inferior to those of BMD. The %CV LSC of BMD for all vertebrae combinations did not exceed 5.3% as recommended by ISCD (15). The %CV LSC of TBS for 2-4 vertebrae combinations were within 5.8% with the exception of the individual vertebra which was unacceptable (%CV range 6.17-8.98). CONCLUSIONS All vertebrae combinations had an acceptable level of precision and LSC for BMD monitoring. However, the precision and LSC of TBS were inferior to those of BMD, and individual vertebra were not appropriate for TBS monitoring. KEYWORDS precision, least significant change (LSC), bone mineral density (BMD), trabecular bone score (TBS)
- 1 January 2024
- Published by Chiang Mai University in Biomedical Sciences and Clinical Medicine
- Vol. 63 (1) , 8-13
Open AccessThe Precision of Lumbar Spine BMD and TBS on Different Vertebral Combinations
OBJECTIVE The objective of this study is to compute the precision and LSC of BMD and TBS at the lumbar spine using dual-energy X-ray absorptiometry in different vertebral combinations. METHODS Thirty female participants (age 58.8 ± 4.0 years, height: 155.0 ± 5.2 cm, weight: 57.4 ± 8.6 kg and BMI: 23.9 ± 3.6) were scanned at the lumbar spine twice in the same day using DXA. The precision and LSC of BMD and TBS were computed in terms of the RMS-SD and %CV using the ISCD Advanced Precision Calculation Tool. RESULTS The precision and LSC of BMD of the 4 vertebrae combinations showed the best precision and also showed a similar trend (0.005 g/cm2 and 0.62%, 0.013 g/cm2 and 1.71%), respectively. For TBS, the precision and LSC followed a similar pattern as BMD but was inferior to those of BMD. The %CV LSC of BMD for all vertebrae combinations did not exceed 5.3% as recommended by ISCD (15). The %CV LSC of TBS for 2-4 vertebrae combinations were within 5.8% with the exception of the individual vertebra which was unacceptable (%CV range 6.17-8.98). CONCLUSIONS All vertebrae combinations had an acceptable level of precision and LSC for BMD monitoring. However, the precision and LSC of TBS were inferior to those of BMD, and individual vertebra were not appropriate for TBS monitoring. KEYWORDS precision, least significant change (LSC), bone mineral density (BMD), trabecular bone score (TBS)