Gideon Villar Leandro
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gideon Villar Leandro has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Gustavo Henrique da Costa Oliveira
Univ Fed Parana, Dept Elect Engn, Curitiba, PR, Brazil
2 shared publications - Roman Kuiava
Federal University of Paraná (UFPR)
2 shared publications - Ádamo Henrique Rocha De Oliveira
Electrical Engineering Department, Federal University of Paran, Curitiba, Brazil
2 shared publications - André Pedretti
Copel - Companhia Paranaense de Energia, Brasil
1 shared publication - Carla Eduarda Orlando de Moraes de Lara
Centro Universitário Internacional (Uninter), Brasil
1 shared publication Carlos Gouvea da Silva
Universidade Federal do Paraná
1 shared publication
Latest Publications
- Open Access
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 213669-213696
A New Hybrid Reference Vector and Grid-Based Evolutionary Algorithm for Dynamic Many-Objective Optimization
Dynamic many-objective optimization problems (DMaOPs) are a class of problems involving more than three objectives. Their objective functions, search space, or constraints may change over time. Dynamic many-objective evolutionary algorithms (DMaOEAs) are typically used to solve DMaOPs and primarily consist of a static optimizer, a change detection mechanism, and a change response mechanism. In this paper, a new hybrid DMaOEA based on the reference vector guided evolutionary algorithm (RVEA) and the grid-based evolutionary algorithm (GrEA), called the dynamic reference vector and grid-based evolutionary algorithm (DRVGrEA), is proposed. In the selection stage of DRVGrEA, a new dynamic angle-penalized distance (DAPD) is introduced to balance convergence and diversity uniformly across all dynamic environments of the problem. At this stage, the GrEA grid-based indicators are still used as a secondary selection mechanism. These mechanisms are applied to different parts of the solutions. To evaluate the performance of the proposed algorithm, several experiments were conducted that compared DRVGrEA with six DMaOEAs, including five based on classical algorithms from the literature and one recently proposed method. The experiments used the SDP1–15 benchmark with 4, 6, 8, 10, 12, and 15 objectives. The results demonstrate that DRVGrEA outperforms or at least matches the performance of the other DMaOEAs. Furthermore, DRVGrEA was also applied to a real-world control problem, namely the PID tuning of an Automatic Voltage Regulator system, where it achieved superior performance compared to all competing algorithms.
- 15 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 213669-213696
Open AccessA New Hybrid Reference Vector and Grid-Based Evolutionary Algorithm for Dynamic Many-Objective Optimization
Dynamic many-objective optimization problems (DMaOPs) are a class of problems involving more than three objectives. Their objective functions, search space, or constraints may change over time. Dynamic many-objective evolutionary algorithms (DMaOEAs) are typically used to solve DMaOPs and primarily consist of a static optimizer, a change detection mechanism, and a change response mechanism. In this paper, a new hybrid DMaOEA based on the reference vector guided evolutionary algorithm (RVEA) and the grid-based evolutionary algorithm (GrEA), called the dynamic reference vector and grid-based evolutionary algorithm (DRVGrEA), is proposed. In the selection stage of DRVGrEA, a new dynamic angle-penalized distance (DAPD) is introduced to balance convergence and diversity uniformly across all dynamic environments of the problem. At this stage, the GrEA grid-based indicators are still used as a secondary selection mechanism. These mechanisms are applied to different parts of the solutions. To evaluate the performance of the proposed algorithm, several experiments were conducted that compared DRVGrEA with six DMaOEAs, including five based on classical algorithms from the literature and one recently proposed method. The experiments used the SDP1–15 benchmark with 4, 6, 8, 10, 12, and 15 objectives. The results demonstrate that DRVGrEA outperforms or at least matches the performance of the other DMaOEAs. Furthermore, DRVGrEA was also applied to a real-world control problem, namely the PID tuning of an Automatic Voltage Regulator system, where it achieved superior performance compared to all competing algorithms.
- Open Access
- 15 November 2024
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 67, e24241072
Day-Ahead Operational Planning of Isolated Microgrids Considering Over/Underestimation Costs for Solar and Wind Power Generation and Battery Degradation Costs
This paper proposes a methodology for the day-ahead operational planning of isolated microgrids equipped with renewable distributed generation based on solar photovoltaic and wind generation systems, energy storage systems, and diesel generation as backup power sources. As one of the main contributions of this paper, the proposed methodology is based on optimal power flow (OPF), considering cost minimization as the objective function that combines probabilistic costs of the renewable distributed generation systems with the determinist cost associated with the degradation of the battery bank. In addition, the cost of fuel consumption associated with the diesel generator is also considered. The costs associated with the renewable distributed generation are modeled by probability density functions, where a reserve cost for overestimation and a penalty cost for underestimation of the output power from these renewable sources are adopted. Hence, the proposed OPF avoids the over/underestimation of the available day-ahead solar and wind generations. The differential evolution optimization technique was used to solve the proposed OPF formulation and to obtain a minimum cost of operation considering the deterministic load profile for the operation of the microgrid under study. The proposed formulation was tested for different solar photovoltaic and wind generation scenarios in a microgrid in Lençóis Island, Brazil, another important contribution of the paper. The obtained results showed that the considered microgrid's day-ahead planning is sensitive to climatic conditions that impact the generation scenario and minimize long-term operating costs.
- 15 November 2024
- Published by FapUNIFESP (SciELO) in Brazilian Archives of Biology and Technology
- Vol. 67, e24241072
Open AccessDay-Ahead Operational Planning of Isolated Microgrids Considering Over/Underestimation Costs for Solar and Wind Power Generation and Battery Degradation Costs
This paper proposes a methodology for the day-ahead operational planning of isolated microgrids equipped with renewable distributed generation based on solar photovoltaic and wind generation systems, energy storage systems, and diesel generation as backup power sources. As one of the main contributions of this paper, the proposed methodology is based on optimal power flow (OPF), considering cost minimization as the objective function that combines probabilistic costs of the renewable distributed generation systems with the determinist cost associated with the degradation of the battery bank. In addition, the cost of fuel consumption associated with the diesel generator is also considered. The costs associated with the renewable distributed generation are modeled by probability density functions, where a reserve cost for overestimation and a penalty cost for underestimation of the output power from these renewable sources are adopted. Hence, the proposed OPF avoids the over/underestimation of the available day-ahead solar and wind generations. The differential evolution optimization technique was used to solve the proposed OPF formulation and to obtain a minimum cost of operation considering the deterministic load profile for the operation of the microgrid under study. The proposed formulation was tested for different solar photovoltaic and wind generation scenarios in a microgrid in Lençóis Island, Brazil, another important contribution of the paper. The obtained results showed that the considered microgrid's day-ahead planning is sensitive to climatic conditions that impact the generation scenario and minimize long-term operating costs.
- Open Access
- 8 December 2020
- Published by Sociedade Brasileira de Automatica
- Vol. 2 (1)
Controladores de Ordem Fracionária: Análise Comparativa entre os Controladores CRONE de Primeira Geração e PID de Ordem Fracionária
Nos últimos anos, o cálculo de ordem fracionária ganhou muita atenção, especialmente no campo da teoria de sistemas dinâmicos e do projeto de sistemas de controle devido a possibilidades mais precisas de modelagem e aprimoramento de controle. Os controladores de ordem fracionária permitem expandir as possíveis ações de controle, para que o projetista tenha uma gama mais ampla de possibilidades de escolha para seu projeto. No entanto, os graus de liberdade são acompanhados com uma complexidade na síntese. Dentro dessa perspectiva, esse trabalho propõe duas comparações: (i) para uma planta de ordem inteira, compara-se um controlador PID de ordem inteira com um controlador CRONE de primeira geração; (ii) para um modelo baseado em uma planta real, compara-se um controlador PID de ordem inteira com um controlador PID de ordem fracionária. Na primeira análise comparativa, o controlador CRONE apresentou uma maior robustez, porém apresentou um esforço de controle maior do que o controlador PID. Já na segunda análise comparativa, os controladores FOPID e PID apresentaram desempenho semelhante, porém o controlador FOPID apresentou um esforço de controle levemente inferior.
- 8 December 2020
- Published by Sociedade Brasileira de Automatica
- Vol. 2 (1)
Open AccessControladores de Ordem Fracionária: Análise Comparativa entre os Controladores CRONE de Primeira Geração e PID de Ordem Fracionária
Nos últimos anos, o cálculo de ordem fracionária ganhou muita atenção, especialmente no campo da teoria de sistemas dinâmicos e do projeto de sistemas de controle devido a possibilidades mais precisas de modelagem e aprimoramento de controle. Os controladores de ordem fracionária permitem expandir as possíveis ações de controle, para que o projetista tenha uma gama mais ampla de possibilidades de escolha para seu projeto. No entanto, os graus de liberdade são acompanhados com uma complexidade na síntese. Dentro dessa perspectiva, esse trabalho propõe duas comparações: (i) para uma planta de ordem inteira, compara-se um controlador PID de ordem inteira com um controlador CRONE de primeira geração; (ii) para um modelo baseado em uma planta real, compara-se um controlador PID de ordem inteira com um controlador PID de ordem fracionária. Na primeira análise comparativa, o controlador CRONE apresentou uma maior robustez, porém apresentou um esforço de controle maior do que o controlador PID. Já na segunda análise comparativa, os controladores FOPID e PID apresentaram desempenho semelhante, porém o controlador FOPID apresentou um esforço de controle levemente inferior.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Monitoring micro phasor measurement units at university campus
This paper presents the results of an ongoing project involving the monitoring of micro phasor measurement units (micro-PMU) at Universidade Federal do Paraná (UFPR). The infrastructure for receiving, processing and storing data from micro-PMUs, energy meters and power quality analysers was deployed. Free software were tested for data storage and visualization. We modified an existing open-source Energy Monitoring System (EMS) for proper use with PMUs. The software native communication protocol was adapted from hypertext protocol (HTTP) to direct reception of user datagram protocol (UDP) in IEEE Std. C37.118.2-2011 format to receive micro-PMUs transmission at 120 phasor per second. We modified data storage format to efficiently deal with time information allowing reduction of 60% of storage space in comparison to commonly used phasor data concentrator (openPDC).
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Monitoring micro phasor measurement units at university campus
This paper presents the results of an ongoing project involving the monitoring of micro phasor measurement units (micro-PMU) at Universidade Federal do Paraná (UFPR). The infrastructure for receiving, processing and storing data from micro-PMUs, energy meters and power quality analysers was deployed. Free software were tested for data storage and visualization. We modified an existing open-source Energy Monitoring System (EMS) for proper use with PMUs. The software native communication protocol was adapted from hypertext protocol (HTTP) to direct reception of user datagram protocol (UDP) in IEEE Std. C37.118.2-2011 format to receive micro-PMUs transmission at 120 phasor per second. We modified data storage format to efficiently deal with time information allowing reduction of 60% of storage space in comparison to commonly used phasor data concentrator (openPDC).