Andriy Zhukov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andriy Zhukov has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Maksym Mushtai
Sumy State University
3 shared publications - Vladyslav Kondus
Sumy State University
3 shared publications - Andrii Krugliak
Sumy State University, Sumy, Ukraine
1 shared publication - Ivan Pavlenko
Department of Computational Mechanics Named after Volodymyr Martsynkovskyy, Sumy State University, 116, Kharkivska St., 40007 Sumy, Ukraine
1 shared publication - Katarzyna Antosz
Rzeszów University of Technology
1 shared publication - Olaf Ciszak
Institute of Mechanical Technology, Poznań University of Technology, 60-965 Poznań, Poland
1 shared publication
Latest Publications
- Open Access
- 16 January 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Hydraulic machines and hydraulic units
- No. 1,p. 23-32
SUSTAINING THE SELF-CLEANING EFFECT OF A TORQUE-FLOW PUMP IN OFF-OPTIMAL MODES
This paper presents the results of a study of a torque-flow pump with a non-uniform blade system, whose design feature is the presence of expanded inter-blade channels that provide conditions for a self-cleaning effect. Unlike previous works, which confirmed the efficiency of this effect only at the optimal flow rate, this research analyzes the pump performance at off-optimal modes within the operating range – 0.8Qbep (100 m³/h) and 1.2Qbep (150 m³/h). Numerical simulations were carried out in ANSYS CFX using three-dimensional geometric models and unstructured computational grids. For each operating point, the complete hydraulic characteristics (head and efficiency) were determined, and the distributions of pressure and velocity in the inter-blade channels were analyzed. It was shown that, even under deviations from the optimal flow rate, the energy performance of the pump with a non-uniform blade system differs from the standard design by no more than 2.5 m in head and 1 % in efficiency. The most important result is the confirmation of the stability of the self-cleaning effect within the operating zone. An asymmetry of pressure distribution and local pulsations were detected in the inter-blade channels, which contribute to the removal of fibrous inclusions from the blade surfaces. It was found that at increased flow rates the intensity of pulsations grows, while at reduced flow rates they remain regular and ensure stable cleaning. Thus, the pump with a non-uniform blade system demonstrates a combination of acceptable energy performance and stable self-cleaning capability throughout the operating zone, which makes it promising for application in wastewater systems and industrial processes where reliability and durability are of critical importance.
- 16 January 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Bulletin of the National Technical University "KhPI". Series: Hydraulic machines and hydraulic units
- No. 1,p. 23-32
Open AccessSUSTAINING THE SELF-CLEANING EFFECT OF A TORQUE-FLOW PUMP IN OFF-OPTIMAL MODES
This paper presents the results of a study of a torque-flow pump with a non-uniform blade system, whose design feature is the presence of expanded inter-blade channels that provide conditions for a self-cleaning effect. Unlike previous works, which confirmed the efficiency of this effect only at the optimal flow rate, this research analyzes the pump performance at off-optimal modes within the operating range – 0.8Qbep (100 m³/h) and 1.2Qbep (150 m³/h). Numerical simulations were carried out in ANSYS CFX using three-dimensional geometric models and unstructured computational grids. For each operating point, the complete hydraulic characteristics (head and efficiency) were determined, and the distributions of pressure and velocity in the inter-blade channels were analyzed. It was shown that, even under deviations from the optimal flow rate, the energy performance of the pump with a non-uniform blade system differs from the standard design by no more than 2.5 m in head and 1 % in efficiency. The most important result is the confirmation of the stability of the self-cleaning effect within the operating zone. An asymmetry of pressure distribution and local pulsations were detected in the inter-blade channels, which contribute to the removal of fibrous inclusions from the blade surfaces. It was found that at increased flow rates the intensity of pulsations grows, while at reduced flow rates they remain regular and ensure stable cleaning. Thus, the pump with a non-uniform blade system demonstrates a combination of acceptable energy performance and stable self-cleaning capability throughout the operating zone, which makes it promising for application in wastewater systems and industrial processes where reliability and durability are of critical importance.
- 18 October 2025
- Published by Springer Nature
- p. 295-304
Design and Modeling of Two-Tier Impellers for Torque-Flow Pumps
- 18 October 2025
- Published by Springer Nature
- p. 295-304
Design and Modeling of Two-Tier Impellers for Torque-Flow Pumps
- Open Access
- 1 January 2024
- Published by Sumy State University in Journal of Engineering Sciences
- Vol. 11 (2) , F17-F26
Development of a Self-Cleaning Mechanism for Torque-Flow Pumps
The design of reliable and durable pumping units is consistent with the achievement of a number of the United Nations’ sustainable development goals (SDG), in particular, “Clean water and proper sanitation” (SDG 6), “Affordable and clean energy” (SDG 7), and “Industry, innovation and infrastructure” (SDG 9). Notably, the use of torque-flow pumps is associated with the need to transport liquids of various types. Such an operating process can cause clogging of the flowing part of the pump (primarily the impeller) by pumping products, mainly wet wipes, solids, and inclusions. As a result of scientific research, an effective self-cleaning mechanism for the torque-flow pump was developed, which was the primary goal. The authors proved that the flow of actual fluid in the interblade channels of the impeller is characterized by an uneven distribution of absolute pressure and relative speed, which is a prerequisite for forming an uneven pulsating nature of motion (the key hypothesis of the study). To implement the proposed hypothesis, an impeller with uniform and non-uniform distribution of blades was developed, and the movement of actual fluid flow in their interblade channels was considered. As a result of the research, it was established that in the expanded interblade channels, there is a pulsation of the absolute (total) pressure value, which is more than 2 times higher than the indicator of an impeller with a uniform distribution of blades. This creates prerequisites for self-cleaning of the developed impeller of the torque-flow pump.
- 1 January 2024
- Published by Sumy State University in Journal of Engineering Sciences
- Vol. 11 (2) , F17-F26
Open AccessDevelopment of a Self-Cleaning Mechanism for Torque-Flow Pumps
The design of reliable and durable pumping units is consistent with the achievement of a number of the United Nations’ sustainable development goals (SDG), in particular, “Clean water and proper sanitation” (SDG 6), “Affordable and clean energy” (SDG 7), and “Industry, innovation and infrastructure” (SDG 9). Notably, the use of torque-flow pumps is associated with the need to transport liquids of various types. Such an operating process can cause clogging of the flowing part of the pump (primarily the impeller) by pumping products, mainly wet wipes, solids, and inclusions. As a result of scientific research, an effective self-cleaning mechanism for the torque-flow pump was developed, which was the primary goal. The authors proved that the flow of actual fluid in the interblade channels of the impeller is characterized by an uneven distribution of absolute pressure and relative speed, which is a prerequisite for forming an uneven pulsating nature of motion (the key hypothesis of the study). To implement the proposed hypothesis, an impeller with uniform and non-uniform distribution of blades was developed, and the movement of actual fluid flow in their interblade channels was considered. As a result of the research, it was established that in the expanded interblade channels, there is a pulsation of the absolute (total) pressure value, which is more than 2 times higher than the indicator of an impeller with a uniform distribution of blades. This creates prerequisites for self-cleaning of the developed impeller of the torque-flow pump.