K. K. Guk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
K. K. Guk has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
N. N. Potrakhov
Petersburg Electrotechnical University LETI, St. Petersburg, Russia
2 shared publications- Nikolay Nikolaevich Potrakhov
Saint Petersburg Electrotechnical University
2 shared publications A V Obodovskiy
Department of electronic instruments and devices, Saint Petersburg Electrotechnical University "LETI", 197376, Saint Petersburg, Russia
1 shared publicationA Yu Gryaznov
Department of electronic instruments and devices, Saint Petersburg Electrotechnical University "LETI", 197376, Saint Petersburg, Russia
1 shared publicationA. D. Kuleshov
Petersburg Electrotechnical University LETI, St. Petersburg, Russia
1 shared publicationA. S. Dmitriev
Petersburg Electrotechnical University LETI, St. Petersburg, Russia
1 shared publication
Latest Publications
- 28 February 2025
- Published by ITMO University in Nanosystems: Physics, Chemistry, Mathematics
- Vol. 16 (1)
Phase-contrast method for determining the size of the effective focal spot of a nanofocus X-ray tube
- 28 February 2025
- Published by ITMO University in Nanosystems: Physics, Chemistry, Mathematics
- Vol. 16 (1)
Phase-contrast method for determining the size of the effective focal spot of a nanofocus X-ray tube
- Open Access
- 22 November 2024
- Published by St. Petersburg Electrotechnical University LETI in Journal of the Russian Universities. Radioelectronics
- Vol. 27 (5) , 77-90
Multifunctional Thermal Imaging Complex for Medical Diagnostics
Introduction. Recent developments in the field of thermal imaging technology and the accumulated experience in instrumental analysis of thermal processes in the patient’s body indicate the prospects of developing new medical thermal imaging systems (thermal imagers).Aim. Creation of a low-budget domestic thermal imaging system for medical diagnostics with expanded functionality.Materials and methods. The distribution of temperature over the surface of the human body depends on its internal state and external environment. For each person, this distribution has its own physiological characteristics, the study and interpretation of which can be significant for diagnosing specific pathologies or assessing the general (psychophysical) state of the patient. Analysis of temperature fields on the surface of the human body makes it possible to diagnose various pathological processes manifested in the form of local temperature changes in individual areas. The proposed method for thermal diagnostics involves measuring the temperature at each point of such an area simultaneously (statically) or over a period of time (dynamically). In comparison with conventional approaches, two thermal imaging sensors are used for this purpose. These include a small-sized matrix (thus being low cost) and a point sensor. Such a combination of sensors provides for the necessary discretization of the temperature field image of sufficiently large areas of the surface of the human body, when shooting from a distance significantly reduced compared to the conventional approach.Results. A conceptual electrical circuit and a layout of a modern thermal imaging system are developed. The advantages of the proposed thermal imager over similar devices are assessed. A method for recording and analyzing temperature in a certain point and temperature fields of both separate areas and large areas on the surface of the human body is proposed and tested.Conclusion. The conducted testing of a material model of the proposed thermal imaging system using the facilities of large medical institutions in St. Petersburg showed its wide functionality along with simplicity and convenience.
- 22 November 2024
- Published by St. Petersburg Electrotechnical University LETI in Journal of the Russian Universities. Radioelectronics
- Vol. 27 (5) , 77-90
Open AccessMultifunctional Thermal Imaging Complex for Medical Diagnostics
Introduction. Recent developments in the field of thermal imaging technology and the accumulated experience in instrumental analysis of thermal processes in the patient’s body indicate the prospects of developing new medical thermal imaging systems (thermal imagers).Aim. Creation of a low-budget domestic thermal imaging system for medical diagnostics with expanded functionality.Materials and methods. The distribution of temperature over the surface of the human body depends on its internal state and external environment. For each person, this distribution has its own physiological characteristics, the study and interpretation of which can be significant for diagnosing specific pathologies or assessing the general (psychophysical) state of the patient. Analysis of temperature fields on the surface of the human body makes it possible to diagnose various pathological processes manifested in the form of local temperature changes in individual areas. The proposed method for thermal diagnostics involves measuring the temperature at each point of such an area simultaneously (statically) or over a period of time (dynamically). In comparison with conventional approaches, two thermal imaging sensors are used for this purpose. These include a small-sized matrix (thus being low cost) and a point sensor. Such a combination of sensors provides for the necessary discretization of the temperature field image of sufficiently large areas of the surface of the human body, when shooting from a distance significantly reduced compared to the conventional approach.Results. A conceptual electrical circuit and a layout of a modern thermal imaging system are developed. The advantages of the proposed thermal imager over similar devices are assessed. A method for recording and analyzing temperature in a certain point and temperature fields of both separate areas and large areas on the surface of the human body is proposed and tested.Conclusion. The conducted testing of a material model of the proposed thermal imaging system using the facilities of large medical institutions in St. Petersburg showed its wide functionality along with simplicity and convenience.
- 1 April 2024
- Published by Pleiades Publishing Ltd in Inorganic Materials
- Vol. 60 (4) , 444-449
High-Voltage Power Supply for X-ray Control of the Structure of Materials
A high-voltage power supply, along with an X-ray tube, is one of the main components of X-ray machines widely used in studying the structure of materials, estimating the internal structure of components and mechanisms, and nondestructive testing of technological processes. In monoblock devices, an X-ray tube and power supply are located in a common housing, while in cable-type setups, an X-ray emitter with the tube and a power supply are connected by a high-voltage cable. In this study, the results of creation of a stabilized high-voltage power supply for X-ray tubes as a part of a cable-type machine are reported. The electric circuits and design of the power supply based on a full-bridge voltage inverter built on power bipolar transistors are developed. The output voltage and power of the source are adjusted through the pulse width modulation of the rectified mains voltage applied to the primary winding of a high-voltage transformer. The use of a solid-state compound with increased thermal conductivity has made it possible to limit the design to forced air cooling of the source and place it within the Rack Mount standard dimensions (4U form factor). The experience of the power supply operation at a large industrial enterprise has shown that its electrical and dimensional parameters provide the possibility of successful use in X-ray machines for structure control of materials.
- 1 April 2024
- Published by Pleiades Publishing Ltd in Inorganic Materials
- Vol. 60 (4) , 444-449
High-Voltage Power Supply for X-ray Control of the Structure of Materials
A high-voltage power supply, along with an X-ray tube, is one of the main components of X-ray machines widely used in studying the structure of materials, estimating the internal structure of components and mechanisms, and nondestructive testing of technological processes. In monoblock devices, an X-ray tube and power supply are located in a common housing, while in cable-type setups, an X-ray emitter with the tube and a power supply are connected by a high-voltage cable. In this study, the results of creation of a stabilized high-voltage power supply for X-ray tubes as a part of a cable-type machine are reported. The electric circuits and design of the power supply based on a full-bridge voltage inverter built on power bipolar transistors are developed. The output voltage and power of the source are adjusted through the pulse width modulation of the rectified mains voltage applied to the primary winding of a high-voltage transformer. The use of a solid-state compound with increased thermal conductivity has made it possible to limit the design to forced air cooling of the source and place it within the Rack Mount standard dimensions (4U form factor). The experience of the power supply operation at a large industrial enterprise has shown that its electrical and dimensional parameters provide the possibility of successful use in X-ray machines for structure control of materials.
- 15 March 2019
- Published by Springer Nature in Biomedical Engineering
- Vol. 52 (6) , 435-438
New Methods for Digital Processing of Microfocus X-Ray Images
- 15 March 2019
- Published by Springer Nature in Biomedical Engineering
- Vol. 52 (6) , 435-438
New Methods for Digital Processing of Microfocus X-Ray Images
- Open Access
- 10 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 872 (1) , 012008
Some questions of designing installations for X-ray inspection
The problems of choosing the source of X-ray radiation for use as part of technological X-ray control installations are considered. The design and main characteristics of a domestic X-ray source based on a microfocus X-ray tube are described.
- 10 July 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 872 (1) , 012008
Open AccessSome questions of designing installations for X-ray inspection
The problems of choosing the source of X-ray radiation for use as part of technological X-ray control installations are considered. The design and main characteristics of a domestic X-ray source based on a microfocus X-ray tube are described.