Nima Gorjian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nima Gorjian has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Christopher W. K. Chow
Sustainable Infrastructure and Resource Management (SIRM), UniSA STEM, University of South Australia, Mawson Lakes, SA 5095, Australia
3 shared publications - Xing Ma
University of South Australia
2 shared publications - Yan Zhuge
UniSA STEM, University of South Australia, Adelaide, Australia
2 shared publications - Amir A. E. Elseady
Sustainable Infrastructure and Resource Management (SIRM), UniSA STEM, University of South Australia, Adelaide, SA 5095, Australia
1 shared publication - Bo Jin
School of Chemical Engineering, The University of Adelaide, Adelaide, SA 5005, Australia
1 shared publication Indra Gunawan
Entrepreneurship, Commercialisation and Innovation Centre (ECIC) The University of Adelaide Adelaide South Australia Australia
1 shared publication
Latest Publications
- Open Access
Development of a Knowledge Graph for Automatic Job Hazard Analysis: The Schema
In the current practice, an essential element of safety management systems, Job Hazard Analysis (JHA), is performed manually, relying on the safety personnel’s experiential knowledge and observations. This research was conducted to create a new ontology that comprehensively represents the JHA knowledge domain, including the implicit knowledge. Specifically, 115 actual JHA documents and interviews with 18 JHA domain experts were analyzed and used as the source of knowledge for creating a new JHA knowledge base, namely the Job Hazard Analysis Knowledge Graph (JHAKG). To ensure the quality of the developed ontology, a systematic approach to ontology development called METHONTOLOGY was used in this process. The case study performed for validation purposes demonstrates that a JHAKG can operate as a knowledge base that answers queries regarding hazards, external factors, level of risks, and appropriate control measures to mitigate risks. As the JHAKG is a database of knowledge representing a large number of actual JHA cases previously developed and also implicit knowledge that has not been formalized in any explicit forms yet, the quality of JHA documents produced from queries to the database is expectedly higher than the ones produced by an individual safety manager in terms of completeness and comprehensiveness.
Open AccessDevelopment of a Knowledge Graph for Automatic Job Hazard Analysis: The Schema
In the current practice, an essential element of safety management systems, Job Hazard Analysis (JHA), is performed manually, relying on the safety personnel’s experiential knowledge and observations. This research was conducted to create a new ontology that comprehensively represents the JHA knowledge domain, including the implicit knowledge. Specifically, 115 actual JHA documents and interviews with 18 JHA domain experts were analyzed and used as the source of knowledge for creating a new JHA knowledge base, namely the Job Hazard Analysis Knowledge Graph (JHAKG). To ensure the quality of the developed ontology, a systematic approach to ontology development called METHONTOLOGY was used in this process. The case study performed for validation purposes demonstrates that a JHAKG can operate as a knowledge base that answers queries regarding hazards, external factors, level of risks, and appropriate control measures to mitigate risks. As the JHAKG is a database of knowledge representing a large number of actual JHA cases previously developed and also implicit knowledge that has not been formalized in any explicit forms yet, the quality of JHA documents produced from queries to the database is expectedly higher than the ones produced by an individual safety manager in terms of completeness and comprehensiveness.
- Open Access
Piezoresistivity and AC Impedance Spectroscopy of Cement-Based Sensors: Basic Concepts, Interpretation, and Perspective
Cement-based sensors include conductive fillers to achieve a sensing capability based on the piezoresistivity phenomenon, in which the electrical resistivity changes with strain. The microstructural characterisation of cement-based sensors can be obtained using a promising non-destructive technique, such as AC impedance spectroscopy (ACIS), which has been recently used by many researchers. This paper reviews the fundamental concepts of piezoresistivity and ACIS in addition to the comparison of equivalent circuit models of cement-based sensors found in the literature. These concepts include piezoresistivity theory, factors affecting piezoresistivity measurement, resistance measurement methodology, strain/damage sensing, causes of piezoresistivity, theories of conduction, AC impedance spectroscopy theory, and the equivalent circuit model. This review aims to provide a comprehensive guide for researchers and practitioners interested in exploring and applying different techniques to self-sensing concrete.
Open AccessPiezoresistivity and AC Impedance Spectroscopy of Cement-Based Sensors: Basic Concepts, Interpretation, and Perspective
Cement-based sensors include conductive fillers to achieve a sensing capability based on the piezoresistivity phenomenon, in which the electrical resistivity changes with strain. The microstructural characterisation of cement-based sensors can be obtained using a promising non-destructive technique, such as AC impedance spectroscopy (ACIS), which has been recently used by many researchers. This paper reviews the fundamental concepts of piezoresistivity and ACIS in addition to the comparison of equivalent circuit models of cement-based sensors found in the literature. These concepts include piezoresistivity theory, factors affecting piezoresistivity measurement, resistance measurement methodology, strain/damage sensing, causes of piezoresistivity, theories of conduction, AC impedance spectroscopy theory, and the equivalent circuit model. This review aims to provide a comprehensive guide for researchers and practitioners interested in exploring and applying different techniques to self-sensing concrete.
- Open Access
Durability of Fibre-Reinforced Calcium Aluminate Cement (CAC)–Ground Granulated Blast Furnace Slag (GGBFS) Blended Mortar after Sulfuric Acid Attack
Concrete wastewater infrastructures are important to modern society but are susceptible to sulfuric acid attack when exposed to an aggressive environment. Fibre-reinforced mortar has been adopted as a promising coating and lining material for degraded reinforced concrete structures due to its unique crack control and excellent anti-corrosion ability. This paper aims to evaluate the performance of polyethylene (PE) fibre-reinforced calcium aluminate cement (CAC)–ground granulated blast furnace slag (GGBFS) blended strain-hardening mortar after sulfuric acid immersion, which represented the aggressive sewer environment. Specimens were exposed to 3% sulfuric acid solution for up to 112 days. Visual, physical and mechanical performance such as water absorption ability, sorptivity, compressive and direct tensile strength were evaluated before and after sulfuric acid attack. In addition, micro-structure changes to the samples after sulfuric acid attack were also assessed by X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM) to further understand the deterioration mechanism. The results show that overall fibre-reinforced calcium aluminate cement (CAC)-based samples performed significantly better than fibre-reinforced ordinary Portland cement (OPC)-based samples as well as mortar samples in sulfuric acid solution in regard to visual observations, penetration depth, direct tensile strength and compressive reduction. Gypsum generation in the cementitious matrix of both CAC and OPC-based systems was the main reason behind the deterioration mechanism after acid attack exposure. Moreover, laboratory sulfuric acid testing has been proven for successfully screening the cementitious material against an acidic environment. This method can be considered to design the service life of concrete wastewater pipes.
Open AccessDurability of Fibre-Reinforced Calcium Aluminate Cement (CAC)–Ground Granulated Blast Furnace Slag (GGBFS) Blended Mortar after Sulfuric Acid Attack
Concrete wastewater infrastructures are important to modern society but are susceptible to sulfuric acid attack when exposed to an aggressive environment. Fibre-reinforced mortar has been adopted as a promising coating and lining material for degraded reinforced concrete structures due to its unique crack control and excellent anti-corrosion ability. This paper aims to evaluate the performance of polyethylene (PE) fibre-reinforced calcium aluminate cement (CAC)–ground granulated blast furnace slag (GGBFS) blended strain-hardening mortar after sulfuric acid immersion, which represented the aggressive sewer environment. Specimens were exposed to 3% sulfuric acid solution for up to 112 days. Visual, physical and mechanical performance such as water absorption ability, sorptivity, compressive and direct tensile strength were evaluated before and after sulfuric acid attack. In addition, micro-structure changes to the samples after sulfuric acid attack were also assessed by X-Ray Diffraction (XRD) and Scanning Electron Microscopy (SEM) to further understand the deterioration mechanism. The results show that overall fibre-reinforced calcium aluminate cement (CAC)-based samples performed significantly better than fibre-reinforced ordinary Portland cement (OPC)-based samples as well as mortar samples in sulfuric acid solution in regard to visual observations, penetration depth, direct tensile strength and compressive reduction. Gypsum generation in the cementitious matrix of both CAC and OPC-based systems was the main reason behind the deterioration mechanism after acid attack exposure. Moreover, laboratory sulfuric acid testing has been proven for successfully screening the cementitious material against an acidic environment. This method can be considered to design the service life of concrete wastewater pipes.
- 24 November 2019
- Published by Wiley in Quality and Reliability Engineering International
- Vol. 36 (2) , 784-796
Reliability modelling with redundancy—A case study of power generation engines in a wastewater treatment plant
Power generators are critical assets in wastewater treatment plants (WWTPs) in Australia and many countries. Better managing the lifetime, minimising failures, improving reliability and availability, and reducing operating and maintenance costs of the power generation assets are still challenging topics for water utilities. This case study aims to develop power generation system reliability and availability modelling considering redundancy to minimise operation and maintenance costs. The two‐parameter Weibull model was used to assess system reliability and availability to power generation engines in WWTPs. The Kaplan‐Meier method (a time‐driven estimation technique) and the log beta‐Weibull model (which is suitable for modelling censored and uncensored data) were used to analyse and validate the modelling results. Shape and scale parameters of the Weibull models were estimated by maximising the log‐likelihood function using non‐linear optimisation. Hazard and reliability functions were calculated using the Weibull model. Results using two‐parameter Weibull, Kaplan‐Meier, and log beta‐Weibull models display low reliability and high hazard rate over time, which was associated with spark plug failure due to a suboptimal start and stop operation strategy.
- 24 November 2019
- Published by Wiley in Quality and Reliability Engineering International
- Vol. 36 (2) , 784-796
Reliability modelling with redundancy—A case study of power generation engines in a wastewater treatment plant
Power generators are critical assets in wastewater treatment plants (WWTPs) in Australia and many countries. Better managing the lifetime, minimising failures, improving reliability and availability, and reducing operating and maintenance costs of the power generation assets are still challenging topics for water utilities. This case study aims to develop power generation system reliability and availability modelling considering redundancy to minimise operation and maintenance costs. The two‐parameter Weibull model was used to assess system reliability and availability to power generation engines in WWTPs. The Kaplan‐Meier method (a time‐driven estimation technique) and the log beta‐Weibull model (which is suitable for modelling censored and uncensored data) were used to analyse and validate the modelling results. Shape and scale parameters of the Weibull models were estimated by maximising the log‐likelihood function using non‐linear optimisation. Hazard and reliability functions were calculated using the Weibull model. Results using two‐parameter Weibull, Kaplan‐Meier, and log beta‐Weibull models display low reliability and high hazard rate over time, which was associated with spark plug failure due to a suboptimal start and stop operation strategy.