Lixiang Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lixiang Xie has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Chunfeng Hu
Department of Radiology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
2 shared publications Cunjie Sun
Department of Radiology, The Affiliated Hospital of Xuzhou Medical University
2 shared publications- Juan Long
Department of Radiology, The Affiliated Hospital of Xuzhou Medical University
2 shared publications - Xiaohan Liu
Department of Radiology, The Affiliated Hospital of Xuzhou Medical University
2 shared publications - Yankai Meng
Department of Radiology, The Affiliated Hospital of Xuzhou Medical University, Xuzhou, China
2 shared publications Aiyun Sun
CT Imaging Research Center, GE Healthcare China, Shanghai, China
1 shared publication
Latest Publications
- 10 August 2026
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 41 (6)
High-pitch Low-dose Chest Computed Tomography With Calcium-aware Reconstruction for Coronary Artery Calcium Scoring
Purpose: To evaluate the accuracy, radiation dose, and clinical feasibility of a high-pitch low-dose chest CT (Sa36LDCT) scanning protocol with calcium-aware reconstruction for coronary artery calcium scoring (CAC). Materials and Methods: In this prospective study, 90 patients underwent both standard CAC scanning (Qr36CACS, 120 kVp) and Sa36LDCT (70 to 120 kVp, high-pitch, ATVS). CAC scoring was quantified as Agatston score, calcium volume, and equivalent mass. Risk stratification was assessed using Agatston categories. Agreement between protocols was evaluated using intraclass correlation coefficients, Bland–Altman analysis, and weighted kappa. Subgroup analyses were performed according to heart rate (≤75 vs. >75 bpm). Radiation dose and subjective image quality were also compared. Results: CAC metrics showed no significant difference between protocols, with excellent agreement (ICC = 0.983 to 0.996). Subgroup analysis revealed that heart rate did not significantly influence CAC quantification or risk classification, with Agatston score ICC values of 0.98 for ≤75 bpm and 0.99 for >75 bpm, demonstrating similar accuracy in both subgroups. Radiation dose reduction was consistently observed across both subgroups, with Sa36LDCT reducing effective radiation dose by 62% (0.74 vs. 0.28 mSv, P < 0.001), without compromising image quality. Risk stratification based on Agatston categories showed near-perfect consistency across heart rate subgroups (weighted k = 0.957). Conclusion: High-pitch Sa36LDCT provides accurate and reliable CAC scoring equivalent to standard CAC scoring, with substantial radiation dose reduction and preserved image quality. The protocol’s robustness across heart rate subgroups demonstrates its potential as a safe and practical approach for combined pulmonary and cardiovascular screening, pending validation in larger, more diverse populations.
- 10 August 2026
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 41 (6)
High-pitch Low-dose Chest Computed Tomography With Calcium-aware Reconstruction for Coronary Artery Calcium Scoring
Purpose: To evaluate the accuracy, radiation dose, and clinical feasibility of a high-pitch low-dose chest CT (Sa36LDCT) scanning protocol with calcium-aware reconstruction for coronary artery calcium scoring (CAC). Materials and Methods: In this prospective study, 90 patients underwent both standard CAC scanning (Qr36CACS, 120 kVp) and Sa36LDCT (70 to 120 kVp, high-pitch, ATVS). CAC scoring was quantified as Agatston score, calcium volume, and equivalent mass. Risk stratification was assessed using Agatston categories. Agreement between protocols was evaluated using intraclass correlation coefficients, Bland–Altman analysis, and weighted kappa. Subgroup analyses were performed according to heart rate (≤75 vs. >75 bpm). Radiation dose and subjective image quality were also compared. Results: CAC metrics showed no significant difference between protocols, with excellent agreement (ICC = 0.983 to 0.996). Subgroup analysis revealed that heart rate did not significantly influence CAC quantification or risk classification, with Agatston score ICC values of 0.98 for ≤75 bpm and 0.99 for >75 bpm, demonstrating similar accuracy in both subgroups. Radiation dose reduction was consistently observed across both subgroups, with Sa36LDCT reducing effective radiation dose by 62% (0.74 vs. 0.28 mSv, P < 0.001), without compromising image quality. Risk stratification based on Agatston categories showed near-perfect consistency across heart rate subgroups (weighted k = 0.957). Conclusion: High-pitch Sa36LDCT provides accurate and reliable CAC scoring equivalent to standard CAC scoring, with substantial radiation dose reduction and preserved image quality. The protocol’s robustness across heart rate subgroups demonstrates its potential as a safe and practical approach for combined pulmonary and cardiovascular screening, pending validation in larger, more diverse populations.
- Open Access
- 1 December 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (12) , 9306-9322
Combining computed tomography features of left atrial epicardial and pericoronary adipose tissue with the triglyceride-glucose index to predict the recurrence of atrial fibrillation after radiofrequency catheter ablation: a machine learning study
Background: Radiofrequency catheter ablation (RFCA) represents an important treatment option for atrial fibrillation (AF); however, the recurrence rate following surgery is relatively high. This study aimed to predict the recurrence of AF after RFCA using interpretable machine learning models that combined the triglyceride-glucose (TyG) index and the quantification of left atrial epicardial and pericoronary adipose tissue. Methods: This retrospective study included 325 patients with AF who underwent their first successful RFCA, among whom 79 had confirmed recurrence. The preoperative clinical data of patients were collected, the TyG index was calculated, and computed tomography (CT) image features were quantitatively measured. Multivariate Cox regression analysis was used to identify the independent risk factors for RFCA recurrence, and adjustments being made for various confounding factors. Post-hoc subgroup analysis was conducted to evaluate the predictive value of the TyG index for recurrence in different patient subgroups. Prediction models based on six machine learning algorithms were constructed. The optimal model’s features were evaluated using Shapley additive explanations (SHAP). Results: After adjustment were made for various confounding factors such as comorbidities of AF, Cox regression showed that the volume of left atrial epicardial adipose tissue (LA-EAT), LA-EAT attenuation, left circumflex coronary artery fat attenuation index (LCX-FAI), and the TyG index were independent risk factors for recurrence after RFCA (Pinteraction=0.660). Conclusions: The SVM model that integrated the TyG index and quantitative CT imaging variables demonstrated good predictive ability for post-RFCA recurrence in patients with AF. Furthermore, the TyG index appeared capable of predicting recurrence independently of T2DM status.
- 1 December 2024
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 14 (12) , 9306-9322
Open AccessCombining computed tomography features of left atrial epicardial and pericoronary adipose tissue with the triglyceride-glucose index to predict the recurrence of atrial fibrillation after radiofrequency catheter ablation: a machine learning study
Background: Radiofrequency catheter ablation (RFCA) represents an important treatment option for atrial fibrillation (AF); however, the recurrence rate following surgery is relatively high. This study aimed to predict the recurrence of AF after RFCA using interpretable machine learning models that combined the triglyceride-glucose (TyG) index and the quantification of left atrial epicardial and pericoronary adipose tissue. Methods: This retrospective study included 325 patients with AF who underwent their first successful RFCA, among whom 79 had confirmed recurrence. The preoperative clinical data of patients were collected, the TyG index was calculated, and computed tomography (CT) image features were quantitatively measured. Multivariate Cox regression analysis was used to identify the independent risk factors for RFCA recurrence, and adjustments being made for various confounding factors. Post-hoc subgroup analysis was conducted to evaluate the predictive value of the TyG index for recurrence in different patient subgroups. Prediction models based on six machine learning algorithms were constructed. The optimal model’s features were evaluated using Shapley additive explanations (SHAP). Results: After adjustment were made for various confounding factors such as comorbidities of AF, Cox regression showed that the volume of left atrial epicardial adipose tissue (LA-EAT), LA-EAT attenuation, left circumflex coronary artery fat attenuation index (LCX-FAI), and the TyG index were independent risk factors for recurrence after RFCA (Pinteraction=0.660). Conclusions: The SVM model that integrated the TyG index and quantitative CT imaging variables demonstrated good predictive ability for post-RFCA recurrence in patients with AF. Furthermore, the TyG index appeared capable of predicting recurrence independently of T2DM status.