Thibaut Cachon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Thibaut Cachon has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
- Eric Viguier
Université de Lyon, VetAgro Sup, ICE, Marcy l’Etoile, France
6 shared publications Eric Viguier
University of Lyon, VetAgro Sup, Interactions Cellules Environnement (ICE), Marcy l’Etoile, France
3 shared publicationsC. Carozzo
Vetagro-Sup, Campus Vétérinaire de Lyon Unité de Chirurgie, Marcy-l’Etoile, France
2 shared publications- Claude Carozzo
Department of Small Animal Surgery, VetAgro Sup, Campus Vétérinaire de Lyon, Université de Lyon, Marcy L'Etoile, France ; Unité ICE UPSP 2011-03-101, VetAgro Sup, Campus Vétérinaire de Lyon, Université de Lyon, Marcy L'Etoile, France
2 shared publications - Didier Fau
Department of Small Animal Surgery, VetAgro Sup, Campus Vétérinaire de Lyon, Université de Lyon, Marcy L'Etoile, France ; Unité ICE UPSP 2011-03-101, VetAgro Sup, Campus Vétérinaire de Lyon, Université de Lyon, Marcy L'Etoile, France
2 shared publications - Joséphine Roels
Surgery Unit, Lyon Veterinary Teaching Hospital, University of Lyon, Veterinary Campus of Vetagro Sup, Marcy L’Etoile, France
2 shared publications
Latest Publications
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Validation pré-clinique d'un dispositif innovant de correction de la scoliose
La scoliose est une déformation en trois dimensions de la colonne vertérbale. Les traitements chirurgicaux actuels sont à l’origine d’une perte de mobilité et de croissance du rachis. Pour palier à ces difficultés, un implant innovant de correction à été développé. Cet implant de type « fusionless » a pour but de préserver la mobilité et la croissance de la colonne vertébrale. Des études morphométriques nous ont permis de connaître la croissance du rachis chez le porc. Cette dernière est maximale entre la 6ème et la 10ème semaine de vie. Les corridors d’insertion des vis pédiculaires ont également pu être décrit. Ensuite, des essais biomécaniques nous ont permis de connaître les contraintes s’exerçant sur le rachis du porc au cours de l’apparition des déformations scoliotiques et de décrire la résistance à l’arrachement des vis pédicualires. Chez le porcs, leur implantation doit etre bicorticale. Enfin, le dispositif a pu être implanté avec succès et a été suivi pendant 2 mois chez 6 porcs charcutiers. Nous avons pu montrer que le dispositif ne semble altérer ni la croissance ni la mobilité rachidienne. Aucune dégénérescence discale n’a été observée
- 3 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Validation pré-clinique d'un dispositif innovant de correction de la scoliose
La scoliose est une déformation en trois dimensions de la colonne vertérbale. Les traitements chirurgicaux actuels sont à l’origine d’une perte de mobilité et de croissance du rachis. Pour palier à ces difficultés, un implant innovant de correction à été développé. Cet implant de type « fusionless » a pour but de préserver la mobilité et la croissance de la colonne vertébrale. Des études morphométriques nous ont permis de connaître la croissance du rachis chez le porc. Cette dernière est maximale entre la 6ème et la 10ème semaine de vie. Les corridors d’insertion des vis pédiculaires ont également pu être décrit. Ensuite, des essais biomécaniques nous ont permis de connaître les contraintes s’exerçant sur le rachis du porc au cours de l’apparition des déformations scoliotiques et de décrire la résistance à l’arrachement des vis pédicualires. Chez le porcs, leur implantation doit etre bicorticale. Enfin, le dispositif a pu être implanté avec succès et a été suivi pendant 2 mois chez 6 porcs charcutiers. Nous avons pu montrer que le dispositif ne semble altérer ni la croissance ni la mobilité rachidienne. Aucune dégénérescence discale n’a été observée
- Open Access
- 25 July 2024
- Published by MDPI AG in Veterinary Sciences
- Vol. 11 (8) , 334
Intra-Articular Surgical Reconstruction of a Canine Cranial Cruciate Ligament Using an Ultra-High-Molecular-Weight Polyethylene Ligament: Case Report with Six-Month Clinical Outcome
The intra-articular reconstruction of the cranial cruciate ligament (CrCL) by an organic graft or a synthetic implant allows the restoration of physiological stifle stability. This treatment is still marginal in routine practice. A Rottweiler presented an acute complete CrCL rupture treated using an ultra-high-molecular-weight polyethylene (UHMWPE) implant. The latter was positioned under arthroscopic guidance and fixed with interference screws through femoral and tibial bone tunnels. The dog was weight-bearing just after surgery and resumed normal standing posture and gait after one month, with mild signs of pain upon stifle manipulation. At three months postoperatively, minimal muscle atrophy and minimal craniocaudal translation were noted on the operated hindlimb, with no effects on the clinical outcome. The stifle was painless. At six months postoperatively, standing posture and gait were normal, muscle atrophy had decreased, the stifle was painless, and the craniocaudal translation was stable. On radiographs, congruent articular surfaces were observed without worsening of osteoarthrosis over the follow-up, as well as stable moderate joint effusion. Replacement of a ruptured CrCL with a UHMWPE ligament yielded good functional clinical outcome at six months postoperatively. This technique could be considered an alternative for the treatment of CrCL rupture in large dogs, but it needs confirmation from a prospective study with more dogs.
- 25 July 2024
- Published by MDPI AG in Veterinary Sciences
- Vol. 11 (8) , 334
Open AccessIntra-Articular Surgical Reconstruction of a Canine Cranial Cruciate Ligament Using an Ultra-High-Molecular-Weight Polyethylene Ligament: Case Report with Six-Month Clinical Outcome
The intra-articular reconstruction of the cranial cruciate ligament (CrCL) by an organic graft or a synthetic implant allows the restoration of physiological stifle stability. This treatment is still marginal in routine practice. A Rottweiler presented an acute complete CrCL rupture treated using an ultra-high-molecular-weight polyethylene (UHMWPE) implant. The latter was positioned under arthroscopic guidance and fixed with interference screws through femoral and tibial bone tunnels. The dog was weight-bearing just after surgery and resumed normal standing posture and gait after one month, with mild signs of pain upon stifle manipulation. At three months postoperatively, minimal muscle atrophy and minimal craniocaudal translation were noted on the operated hindlimb, with no effects on the clinical outcome. The stifle was painless. At six months postoperatively, standing posture and gait were normal, muscle atrophy had decreased, the stifle was painless, and the craniocaudal translation was stable. On radiographs, congruent articular surfaces were observed without worsening of osteoarthrosis over the follow-up, as well as stable moderate joint effusion. Replacement of a ruptured CrCL with a UHMWPE ligament yielded good functional clinical outcome at six months postoperatively. This technique could be considered an alternative for the treatment of CrCL rupture in large dogs, but it needs confirmation from a prospective study with more dogs.
- 6 November 2023
- Published by Elsevier in Veterinary Anaesthesia and Analgesia
- Vol. 50 (6) , 537
Analgesic effect of compressive cryotherapy after orthopaedic surgery in dogs
- 6 November 2023
- Published by Elsevier in Veterinary Anaesthesia and Analgesia
- Vol. 50 (6) , 537
Analgesic effect of compressive cryotherapy after orthopaedic surgery in dogs
- 8 September 2022
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 24 (10) , e360-e369
Validation of a biomechanical testing protocol of craniodorsal hip luxation in feline cadavers and comparison of two ultra-high molecular weight polyethylene materials used for extra-articular hip stabilisation
Objectives: The aim of our study was to describe a biomechanical testing protocol to reproduce ex vivo craniodorsal hip luxation specific to the feline model, and evaluate the biomechanical properties of an intact hip joint compared with the fixation strength of two different techniques of extra-articular hip stabilisation. Methods: Eighteen hip joints (femur and hemipelvis) were harvested from nine mature feline cadavers. CT was performed for each hip joint so that a biomechanical base specific to each joint morphotype could be created using computer-aided design. The biomechanical bases were then produced using a three-dimensional printer to secure the hip joints during testing. A total of 34 biomechanical compression tests were performed. Eighteen compression tests were performed in the control group, of which two fractured. The remaining 16 hip joints were then randomly assigned either to group A (hip joints stabilised with an extra-articular ultra-high molecular weight polyethylene (UHMWPE) implant secured by an interference screw [n = 8]) or to group B (hip joints stabilised with a UHMWPE iliofemoral suture [n = 8]). Results: Mean ± SD yield, failure load and linear stiffness in the control group were 616 ± 168 N, 666 ± 158 N and 231 ± 50 N/mm, respectively. The relative fixation strength (% of intact joint) before hip luxation in groups A and B was 43.8% and 34.7%, respectively. No statistical difference was found between groups A and B for yield and failure load. However, the reoccurrence of craniodorsal hip luxation was higher in group B than in group A, in 5/8 and 0/8 tests, respectively. Moreover, in group A, the extra-articular UHMWPE implant induced caudodorsal hip luxation, reported as failure mode in 7/8 cases. Conclusions and relevance: This modified biomechanical protocol for testing craniodorsal hip luxation in a feline model was validated as repeatable and with acceptable variance. The extra-articular UHMWPE implant stabilisation technique proved to be more efficient in avoiding reoccurrence of craniodorsal hip luxation than UHMWPE iliofemoral suture.
- 8 September 2022
- Published by SAGE Publications in Journal of Feline Medicine and Surgery
- Vol. 24 (10) , e360-e369
Validation of a biomechanical testing protocol of craniodorsal hip luxation in feline cadavers and comparison of two ultra-high molecular weight polyethylene materials used for extra-articular hip stabilisation
Objectives: The aim of our study was to describe a biomechanical testing protocol to reproduce ex vivo craniodorsal hip luxation specific to the feline model, and evaluate the biomechanical properties of an intact hip joint compared with the fixation strength of two different techniques of extra-articular hip stabilisation. Methods: Eighteen hip joints (femur and hemipelvis) were harvested from nine mature feline cadavers. CT was performed for each hip joint so that a biomechanical base specific to each joint morphotype could be created using computer-aided design. The biomechanical bases were then produced using a three-dimensional printer to secure the hip joints during testing. A total of 34 biomechanical compression tests were performed. Eighteen compression tests were performed in the control group, of which two fractured. The remaining 16 hip joints were then randomly assigned either to group A (hip joints stabilised with an extra-articular ultra-high molecular weight polyethylene (UHMWPE) implant secured by an interference screw [n = 8]) or to group B (hip joints stabilised with a UHMWPE iliofemoral suture [n = 8]). Results: Mean ± SD yield, failure load and linear stiffness in the control group were 616 ± 168 N, 666 ± 158 N and 231 ± 50 N/mm, respectively. The relative fixation strength (% of intact joint) before hip luxation in groups A and B was 43.8% and 34.7%, respectively. No statistical difference was found between groups A and B for yield and failure load. However, the reoccurrence of craniodorsal hip luxation was higher in group B than in group A, in 5/8 and 0/8 tests, respectively. Moreover, in group A, the extra-articular UHMWPE implant induced caudodorsal hip luxation, reported as failure mode in 7/8 cases. Conclusions and relevance: This modified biomechanical protocol for testing craniodorsal hip luxation in a feline model was validated as repeatable and with acceptable variance. The extra-articular UHMWPE implant stabilisation technique proved to be more efficient in avoiding reoccurrence of craniodorsal hip luxation than UHMWPE iliofemoral suture.
- Open Access
- 17 January 2022
- Published by Elsevier in Veterinary and Animal Science
- Vol. 15, 100233
A morphometric analysis of thoracolumbar vertebrae in goat by computed tomography.
- 17 January 2022
- Published by Elsevier in Veterinary and Animal Science
- Vol. 15, 100233
Open AccessA morphometric analysis of thoracolumbar vertebrae in goat by computed tomography.
- Open Access
- 1 January 2022
- Published by ScopeMed in Open Veterinary Journal
- Vol. 12 (3) , 341-350
Biomechanical cyclic loading test of a synthetic ligament fixation system used for intra-articular stabilization of deficient canine stifles
Background: Cranial cruciate ligament rupture (CCLr) is the most common cause of hindlimb lameness in dogs. Currently, surgical management of CCLr is mostly performed using tibial osteotomy techniques to modify the biomechanical conformation of the affected stifle. These surgical techniques have a significant complication rate, associated with persistent instability of the stifle which may lead to chronic postoperative pain. Over the last decade, studies have been published on various techniques of anatomical CCL reconstruction in veterinary practice, using physiological autografts or woven synthetic implants. Aim: The aim of this ex vivo biomechanical study is to investigate the ex vivo dynamic biomechanical behavior of a synthetic implant (ultra-high molecular weight polyethylene implant) fixed with interference screws for the treatment of cranial cruciate ligament rupture in dogs, according to a fatigue protocol (48h per test). Methods: Seven stifles from four skeletally mature canine cadavers were implanted with the synthetic implant. It was fixed with four interference screws inserted in transversal and oblique tunnels in both the distal femur and the proximal tibia. For each case, 100 000 cycles were performed at 0.58Hz, with traction loads ranging from 100N to 210N. Results: Neither screw-bone assembly rupture nor a pull-out issue were observed during the dynamic tests. The linear stiffness of the implants associated with a fixation system with four interference screws increased over time. The final displacement did not exceed 3mm for five of the seven specimens. Five of the seven synthetic implants yielded to a lengthening in functional range [0: 3 mm]. Linear stiffness was homogeneous among samples, showing a strong dynamic strength of the interference screw-based fixations of the UHMWPE implant in the femoral and tibial bones. Conclusion: This study completes the existing literature on the biomechanical evaluation of passive stifle stabilization techniques with a testing protocol focused on cyclic loading at a given force level instead of driven by displacement. These biomechanical results should revive interest in intra-articular reconstruction after rupture of the cranial cruciate ligament in dogs.
- 1 January 2022
- Published by ScopeMed in Open Veterinary Journal
- Vol. 12 (3) , 341-350
Open AccessBiomechanical cyclic loading test of a synthetic ligament fixation system used for intra-articular stabilization of deficient canine stifles
Background: Cranial cruciate ligament rupture (CCLr) is the most common cause of hindlimb lameness in dogs. Currently, surgical management of CCLr is mostly performed using tibial osteotomy techniques to modify the biomechanical conformation of the affected stifle. These surgical techniques have a significant complication rate, associated with persistent instability of the stifle which may lead to chronic postoperative pain. Over the last decade, studies have been published on various techniques of anatomical CCL reconstruction in veterinary practice, using physiological autografts or woven synthetic implants. Aim: The aim of this ex vivo biomechanical study is to investigate the ex vivo dynamic biomechanical behavior of a synthetic implant (ultra-high molecular weight polyethylene implant) fixed with interference screws for the treatment of cranial cruciate ligament rupture in dogs, according to a fatigue protocol (48h per test). Methods: Seven stifles from four skeletally mature canine cadavers were implanted with the synthetic implant. It was fixed with four interference screws inserted in transversal and oblique tunnels in both the distal femur and the proximal tibia. For each case, 100 000 cycles were performed at 0.58Hz, with traction loads ranging from 100N to 210N. Results: Neither screw-bone assembly rupture nor a pull-out issue were observed during the dynamic tests. The linear stiffness of the implants associated with a fixation system with four interference screws increased over time. The final displacement did not exceed 3mm for five of the seven specimens. Five of the seven synthetic implants yielded to a lengthening in functional range [0: 3 mm]. Linear stiffness was homogeneous among samples, showing a strong dynamic strength of the interference screw-based fixations of the UHMWPE implant in the femoral and tibial bones. Conclusion: This study completes the existing literature on the biomechanical evaluation of passive stifle stabilization techniques with a testing protocol focused on cyclic loading at a given force level instead of driven by displacement. These biomechanical results should revive interest in intra-articular reconstruction after rupture of the cranial cruciate ligament in dogs.
- Open Access
- 1 May 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (sup1) , S463-S464
Ex vivo biomechanical study on a porcine model of three types of stabilisation in scoliosis treatment
- 1 May 2019
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 22 (sup1) , S463-S464
Open AccessEx vivo biomechanical study on a porcine model of three types of stabilisation in scoliosis treatment
- Open Access
- 20 February 2019
- Published by MDPI AG in Biomimetics
- Vol. 4 (1) , 19
Cellulose Nanofiber-Reinforced Chitosan Hydrogel Composites for Intervertebral Disc Tissue Repair
The development of non-cellularized composites of chitosan (CHI) hydrogels, filled with cellulose nanofibers (CNFs) of the type nanofibrillated cellulose, was proposed for the repair and regeneration of the intervertebral disc (IVD) annulus fibrosus (AF) tissue. With the achievement of CNF-filled CHI hydrogels, biomaterial-based implants were designed to restore damaged/degenerated discs. The structural, mechanical and biological properties of the developed hydrogel composites were investigated. The neutralization of weakly acidic aqueous CNF/CHI viscous suspensions in NaOH yielded composites of physical hydrogels in which the cellulose nanofibers reinforced the CHI matrix, as investigated by means of microtensile testing under controlled humidity. We assessed the suitability of the achieved biomaterials for intervertebral disc tissue engineering in ex vivo experiments using spine pig models. Cellulose nanofiber-filled chitosan hydrogels can be used as implants in AF tissue defects to restore IVD biomechanics and constitute contention patches against disc nucleus protrusion while serving as support for IVD regeneration.
- 20 February 2019
- Published by MDPI AG in Biomimetics
- Vol. 4 (1) , 19
Open AccessCellulose Nanofiber-Reinforced Chitosan Hydrogel Composites for Intervertebral Disc Tissue Repair
The development of non-cellularized composites of chitosan (CHI) hydrogels, filled with cellulose nanofibers (CNFs) of the type nanofibrillated cellulose, was proposed for the repair and regeneration of the intervertebral disc (IVD) annulus fibrosus (AF) tissue. With the achievement of CNF-filled CHI hydrogels, biomaterial-based implants were designed to restore damaged/degenerated discs. The structural, mechanical and biological properties of the developed hydrogel composites were investigated. The neutralization of weakly acidic aqueous CNF/CHI viscous suspensions in NaOH yielded composites of physical hydrogels in which the cellulose nanofibers reinforced the CHI matrix, as investigated by means of microtensile testing under controlled humidity. We assessed the suitability of the achieved biomaterials for intervertebral disc tissue engineering in ex vivo experiments using spine pig models. Cellulose nanofiber-filled chitosan hydrogels can be used as implants in AF tissue defects to restore IVD biomechanics and constitute contention patches against disc nucleus protrusion while serving as support for IVD regeneration.
- Open Access
- 23 October 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0184857
Safe corridor for the implantation of thoracolumbar pedicle screws in growing pigs: A morphometric study
The pig spine is widely used as a large animal model for preclinical research in human medicine to test new spinal implants and surgical procedures. Among them, pedicle screw is one of the most common method of fixation of those implants. However, the pedicle of the porcine vertebra is not as well defined and not as large as the pedicle of the human vertebra. Therefore, the position of the screw should be adapted to the pig and not merely transposed based on the literature on humans. The purpose of this study is to determine the characteristics of the optimum implantation corridors for pedicle screws in the thoracolumbar spine of piglets of different ages using computed tomography (CT) and to determine the size and length of these corridors in pigs of different ages. CT scans from five groups of age: 6, 10, 14, 18, and 26 weeks were reviewed. For each thoracolumbar vertebrae, the pedicle width, pedicle axis length, and the pedicle angle was measured for the left and right pedicle. A total of 326 thoracic vertebrae and 126 lumbar vertebrae were included in the study. Pedicles are statistically larger but not longer for the lumbar vertebrae. An important variation of the pedicle angle is observed along the spine. In all pigs, an abrupt modification of the pedicle angle between T10 and T11 was observed, which corresponds to the level of the anticlinal vertebra which is the vertebra for which the spinous process is nearly perpendicular to the vertebral body. In conclusion, this study provides a quantitative database of pedicle screw implantation corridors in pigs of different ages. When using pedicle screws in experimental studies in pigs, these results should be considered for selecting the most suitable implants for the study but also to ensure a correct and safer screw position. Improving study procedures may limit postoperative complications and pain, thereby limiting the use of live animals.
- 23 October 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0184857
Open AccessSafe corridor for the implantation of thoracolumbar pedicle screws in growing pigs: A morphometric study
The pig spine is widely used as a large animal model for preclinical research in human medicine to test new spinal implants and surgical procedures. Among them, pedicle screw is one of the most common method of fixation of those implants. However, the pedicle of the porcine vertebra is not as well defined and not as large as the pedicle of the human vertebra. Therefore, the position of the screw should be adapted to the pig and not merely transposed based on the literature on humans. The purpose of this study is to determine the characteristics of the optimum implantation corridors for pedicle screws in the thoracolumbar spine of piglets of different ages using computed tomography (CT) and to determine the size and length of these corridors in pigs of different ages. CT scans from five groups of age: 6, 10, 14, 18, and 26 weeks were reviewed. For each thoracolumbar vertebrae, the pedicle width, pedicle axis length, and the pedicle angle was measured for the left and right pedicle. A total of 326 thoracic vertebrae and 126 lumbar vertebrae were included in the study. Pedicles are statistically larger but not longer for the lumbar vertebrae. An important variation of the pedicle angle is observed along the spine. In all pigs, an abrupt modification of the pedicle angle between T10 and T11 was observed, which corresponds to the level of the anticlinal vertebra which is the vertebra for which the spinous process is nearly perpendicular to the vertebral body. In conclusion, this study provides a quantitative database of pedicle screw implantation corridors in pigs of different ages. When using pedicle screws in experimental studies in pigs, these results should be considered for selecting the most suitable implants for the study but also to ensure a correct and safer screw position. Improving study procedures may limit postoperative complications and pain, thereby limiting the use of live animals.
- Open Access
- 9 November 2016
- Published by Wiley in Veterinary Record Case Reports
- Vol. 4 (2) , e000348
Avulsion fracture of the femoral attachment of the caudal cruciate ligament treated by arthroscopy in a Bernese Mountain puppy
A five‐month‐old male Bernese Mountain dog weighing 27.4 kg was presented for evaluation of an acute non‐weightbearing left pelvic limb lameness. Radiographs and CT revealed an avulsion fracture of the femoral attachment of the caudal cruciate ligament (CaCL). A left stifle arthroscopy was performed. Reduction and internal fixation were realised under arthroscopic guidance using a Kirschner wire (1.8 mm) and a single cortical screw (2.0 mm). Ten weeks postoperatively, the implants were removed via arthroscopy. A mild persistent intermittent weightbearing lameness was noted. Normal healing and resolution of lameness followed and the dog was clinically healthy 6 months postoperatively. As in human medicine, surgical treatment of a CaCL avulsion injury in dogs can be performed under arthroscopic guidance. Even though surgical treatment is not always required, it seemed indicated in this case and arthroscopic treatment was successful.
- 9 November 2016
- Published by Wiley in Veterinary Record Case Reports
- Vol. 4 (2) , e000348
Open AccessAvulsion fracture of the femoral attachment of the caudal cruciate ligament treated by arthroscopy in a Bernese Mountain puppy
A five‐month‐old male Bernese Mountain dog weighing 27.4 kg was presented for evaluation of an acute non‐weightbearing left pelvic limb lameness. Radiographs and CT revealed an avulsion fracture of the femoral attachment of the caudal cruciate ligament (CaCL). A left stifle arthroscopy was performed. Reduction and internal fixation were realised under arthroscopic guidance using a Kirschner wire (1.8 mm) and a single cortical screw (2.0 mm). Ten weeks postoperatively, the implants were removed via arthroscopy. A mild persistent intermittent weightbearing lameness was noted. Normal healing and resolution of lameness followed and the dog was clinically healthy 6 months postoperatively. As in human medicine, surgical treatment of a CaCL avulsion injury in dogs can be performed under arthroscopic guidance. Even though surgical treatment is not always required, it seemed indicated in this case and arthroscopic treatment was successful.