Alexander N Karpushov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Alexander N Karpushov has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
- Basil P Duval
École Polytechnique Fédérale de Lausanne
12 shared publications - J. Poley-Sanjuán
Ecole Polytechnique Fédérale de Lausanne (EPFL), Swiss Plasma Center (SPC), CH-1015 Lausanne, Switzerland
8 shared publications - Ambrogio Fasoli
École Polytechnique Fédérale de Lausanne
7 shared publications - Mykola Dreval
Kharkiv Institute of Physics and Technology
7 shared publications - Mario Podesta
École Polytechnique Fédérale de Lausanne
6 shared publications - Anton Jansen van Vuuren
École Polytechnique Fédérale de Lausanne (EPFL)
5 shared publications
Latest Publications
- 1 August 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (8) , 082501
Space structure of the EGAM modes in TCV, experimental observations and modeling
The complex spatial structure of energetic-particle-driven geodesic acoustic modes (EGAMs) has been recently observed experimentally in the TCV tokamak (Dreval et al 2025 Nucl. Fusion 65 016037). In the present work, we model the spatial structure of EGAM modes in the TCV equilibrium using a realistic fast ion distribution function, implemented in the gyrokinetic particle-in-cell code ORB5. For a peaked radial profile of fast ions, the EGAM spatial structure coincides with that of the conventional geodesic acoustic mode, characterized by an nm −1 = 0/0 plasma potential perturbation and an m = 1 standing density perturbation, where the amplitude of the density oscillations is proportional to the sine of the poloidal angle. In contrast, for a hollow fast-ion radial profile and a marginally stable mode, our simulations reproduce a complex EGAM spatial structure similar to that observed experimentally in TCV, with two coexisting density fluctuation frequencies at different radial locations.
- 1 August 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (8) , 082501
Space structure of the EGAM modes in TCV, experimental observations and modeling
The complex spatial structure of energetic-particle-driven geodesic acoustic modes (EGAMs) has been recently observed experimentally in the TCV tokamak (Dreval et al 2025 Nucl. Fusion 65 016037). In the present work, we model the spatial structure of EGAM modes in the TCV equilibrium using a realistic fast ion distribution function, implemented in the gyrokinetic particle-in-cell code ORB5. For a peaked radial profile of fast ions, the EGAM spatial structure coincides with that of the conventional geodesic acoustic mode, characterized by an nm −1 = 0/0 plasma potential perturbation and an m = 1 standing density perturbation, where the amplitude of the density oscillations is proportional to the sine of the poloidal angle. In contrast, for a hollow fast-ion radial profile and a marginally stable mode, our simulations reproduce a complex EGAM spatial structure similar to that observed experimentally in TCV, with two coexisting density fluctuation frequencies at different radial locations.
- Open Access
- 25 June 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086025
Axisymmetric global Alfvén eigenmodes in the TCV tokamak
Global Alfvén eigenmodes (GAEs) with toroidal mode number n=0 (i.e., axisymmetric) have been observed in the toroidicity-induced, ellipticity-induced, and above non-circularity-induced frequency ranges in the TCV tokamak. The observed periodicity of the n=0 GAEs, caused by the periodic structure of the Alfvén continuum, demonstrates the fundamental nature of these modes. A radial splitting of the n=0 GAEs has been observed. This observation is consistent with the recently observed radial splitting of GAEs in the sub-cyclotron frequency range. Linear MHD codes were used to compute the n=0 Alfvén continuum and the corresponding eigenmode structures. The modeling confirms that the n=0 GAEs are located only below the minima of the Alfvén continuum, in contrast to the sub-cyclotron-frequency GAEs, for which modes above the continuum maxima are also observed. The n=0 GAEs have been observed in a variety of discharge types, including low- and high-density plasmas, positive- and negative-triangularity configurations, and discharges with neutral beam injection in both co-current and counter-current directions. A key factor for the appearance of n=0 GAEs is a positive gradient in the particle energy distribution function, ∂f/∂E>0 (bump-on-tail), which has been confirmed by TRANSP calculations for all discharges.
- 25 June 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086025
Open AccessAxisymmetric global Alfvén eigenmodes in the TCV tokamak
Global Alfvén eigenmodes (GAEs) with toroidal mode number n=0 (i.e., axisymmetric) have been observed in the toroidicity-induced, ellipticity-induced, and above non-circularity-induced frequency ranges in the TCV tokamak. The observed periodicity of the n=0 GAEs, caused by the periodic structure of the Alfvén continuum, demonstrates the fundamental nature of these modes. A radial splitting of the n=0 GAEs has been observed. This observation is consistent with the recently observed radial splitting of GAEs in the sub-cyclotron frequency range. Linear MHD codes were used to compute the n=0 Alfvén continuum and the corresponding eigenmode structures. The modeling confirms that the n=0 GAEs are located only below the minima of the Alfvén continuum, in contrast to the sub-cyclotron-frequency GAEs, for which modes above the continuum maxima are also observed. The n=0 GAEs have been observed in a variety of discharge types, including low- and high-density plasmas, positive- and negative-triangularity configurations, and discharges with neutral beam injection in both co-current and counter-current directions. A key factor for the appearance of n=0 GAEs is a positive gradient in the particle energy distribution function, ∂f/∂E>0 (bump-on-tail), which has been confirmed by TRANSP calculations for all discharges.
- Open Access
- 19 June 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086033
First observations of ion cyclotron emission in the TCV tokamak
The first observations of ion cyclotron emission (ICE) in the TCV tokamak are reported. The measured ICE frequency closely follows the deuterium ion cyclotron frequency at the magnetic axis, with temporal variations consistent with equilibrium evolution and associated shifts of the magnetic axis. Core ICE is observed primarily during phases with combined electron cyclotron resonance heating (ECRH) and neutral beam injection (NBI). In most discharges the second harmonic dominates, while in others higher harmonics (third or fourth) are observed. Fine spectral structure, including branch splitting and frequency chirping, is frequently detected, together with additional modes consistent with edge cyclotron harmonics. Core ICE is observed during both co-current and counter-current NBI. The frequency offset of core ICE relative to the ion cyclotron harmonic at the magnetic axis reverses sign between co- and counter-current injection, and this behaviour is confirmed in discharges with reversed plasma current. The observed frequency shifts are consistent with excitation via Doppler-shifted cyclotron resonances.
- 19 June 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (8) , 086033
Open AccessFirst observations of ion cyclotron emission in the TCV tokamak
The first observations of ion cyclotron emission (ICE) in the TCV tokamak are reported. The measured ICE frequency closely follows the deuterium ion cyclotron frequency at the magnetic axis, with temporal variations consistent with equilibrium evolution and associated shifts of the magnetic axis. Core ICE is observed primarily during phases with combined electron cyclotron resonance heating (ECRH) and neutral beam injection (NBI). In most discharges the second harmonic dominates, while in others higher harmonics (third or fourth) are observed. Fine spectral structure, including branch splitting and frequency chirping, is frequently detected, together with additional modes consistent with edge cyclotron harmonics. Core ICE is observed during both co-current and counter-current NBI. The frequency offset of core ICE relative to the ion cyclotron harmonic at the magnetic axis reverses sign between co- and counter-current injection, and this behaviour is confirmed in discharges with reversed plasma current. The observed frequency shifts are consistent with excitation via Doppler-shifted cyclotron resonances.
- Top Cited PapersOpen Access
- 13 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (11)
Progress and innovations in the TCV tokamak research programme
Research on the Tokamak à Configuration Variable (TCV) addresses a wide range of key questions relevant to ITER and future fusion power plants. Over the past two years, highly productive experimental campaigns have led to major advances across several areas: the ITER baseline scenario; pedestal properties in low-collisionality, peeling-limited conditions; and the development of high-$\beta_N$, non-inductive regimes. Alternative high-confinement scenarios have likewise received significant attention, with remarkable progress in quasi-continuous exhaust operation, X-point radiator plasmas, and negative triangularity configurations. Substantial achievements were also made in the mitigation or benign termination of runaway electron beams, in elucidating fast-ion loss mechanisms, and in improving exhaust behaviour in both conventional and alternative divertor geometries. These experimental results have been strongly supported by advances in modelling and their direct application to the experiment, ranging from gyrokinetic simulations of core and pedestal turbulence to fluid-based studies of scrape-off layer and divertor physics in diverse geometries. Plasma control has taken on an increasingly important role, with model-based and data-driven approaches now closely intertwined with physics studies. This article provides a overview of these recent activities, together with a brief outlook on forthcoming upgrades and next steps.
- 13 May 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (11)
Top Cited PapersOpen AccessProgress and innovations in the TCV tokamak research programme
Research on the Tokamak à Configuration Variable (TCV) addresses a wide range of key questions relevant to ITER and future fusion power plants. Over the past two years, highly productive experimental campaigns have led to major advances across several areas: the ITER baseline scenario; pedestal properties in low-collisionality, peeling-limited conditions; and the development of high-$\beta_N$, non-inductive regimes. Alternative high-confinement scenarios have likewise received significant attention, with remarkable progress in quasi-continuous exhaust operation, X-point radiator plasmas, and negative triangularity configurations. Substantial achievements were also made in the mitigation or benign termination of runaway electron beams, in elucidating fast-ion loss mechanisms, and in improving exhaust behaviour in both conventional and alternative divertor geometries. These experimental results have been strongly supported by advances in modelling and their direct application to the experiment, ranging from gyrokinetic simulations of core and pedestal turbulence to fluid-based studies of scrape-off layer and divertor physics in diverse geometries. Plasma control has taken on an increasingly important role, with model-based and data-driven approaches now closely intertwined with physics studies. This article provides a overview of these recent activities, together with a brief outlook on forthcoming upgrades and next steps.
- Open Access
- 16 March 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (4) , 046012
Fast ion confinement in negative triangularity plasmas on the TCV tokamak
Negative triangularity (NT) plasma configurations have been extensively studied in the Tokamak á Configuration Variable (TCV), and have displayed enhanced heat confinement for thermal electrons and ions. Herein, the question of fast-ion confinement is addressed. Limited NT and positive triangularity (PT) plasmas are compared. The plasma volume and position are kept the same between the discharges to match the neutral beam heating deposition, isolating the effect of triangularity. These plasmas were MHD-quiescent with quasi-stationary conditions, minimising additional MHD-induced transport. The upgraded TCV Fast Ion Loss Detector (FILD) and the fast neutron detector were used as the main diagnostics to probe the lost and confined fast-ion population. The FILD signal was higher for NT, suggesting higher fast-ion losses. The neutron production was, however, higher in the NT case, suggesting a higher confined fast-ion population. Modelling was able to reproduce the main experimental observations well, using neoclassical transport alone. The slowing-down fast-ion content was computed to be higher in the NT case, with fast-ion orbit-following indicating that this shape changed the relative number of fast-ion losses arriving at the FILD, while the total number of fast-ion losses to the wall remained similar. The discrepancy in the confined fast-ion population was mainly attributed to the charge-exchange fast-ion losses, which are significantly higher for the PT case.
- 16 March 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (4) , 046012
Open AccessFast ion confinement in negative triangularity plasmas on the TCV tokamak
Negative triangularity (NT) plasma configurations have been extensively studied in the Tokamak á Configuration Variable (TCV), and have displayed enhanced heat confinement for thermal electrons and ions. Herein, the question of fast-ion confinement is addressed. Limited NT and positive triangularity (PT) plasmas are compared. The plasma volume and position are kept the same between the discharges to match the neutral beam heating deposition, isolating the effect of triangularity. These plasmas were MHD-quiescent with quasi-stationary conditions, minimising additional MHD-induced transport. The upgraded TCV Fast Ion Loss Detector (FILD) and the fast neutron detector were used as the main diagnostics to probe the lost and confined fast-ion population. The FILD signal was higher for NT, suggesting higher fast-ion losses. The neutron production was, however, higher in the NT case, suggesting a higher confined fast-ion population. Modelling was able to reproduce the main experimental observations well, using neoclassical transport alone. The slowing-down fast-ion content was computed to be higher in the NT case, with fast-ion orbit-following indicating that this shape changed the relative number of fast-ion losses arriving at the FILD, while the total number of fast-ion losses to the wall remained similar. The discrepancy in the confined fast-ion population was mainly attributed to the charge-exchange fast-ion losses, which are significantly higher for the PT case.
- Open Access
- 29 January 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (3) , 036009
Dynamics of the fast-ion acceleration in type-I ELMy H-mode scenarios on the TCV tokamak
Fast ions have been observed to be accelerated in the presence of Edge Localised Modes (ELMs) and MHD activity on the Tokamak á Configuration Variable. The acceleration time, velocity-space and frequency dynamics have been resolved by analysing the fast-ion losses measured using a unique Fast Ion Loss Detector (FILD) that allows microsecond velocity-space mapping. The findings presented herein complement and extend previous studies done at the Asdex Upgrade Tokamak and show a decorrelation between the acceleration and the ELM crash. The experimental scenario is a high-confinement mode (H-mode) plasma, characterised by low density, high electron temperature and, hence, long slowing down times of the fast-ion population. Significant MHD activity has been observed in the inter-ELM-crash period with frequencies ranging from 50 to 250 kHz. These modes exhibit strong down-chirping and burst signatures. The empirical dependence of the modes’ frequency upon the plasma density identifies them as Alfvén Eigenmodes (AEs) and locates them in the outer region of the plasma, where the resonance conditions between the fast ions and modes are fulfilled. Their resonant interaction with the fast-ion, generated using a Neutral Beam Injector, changes during the ELM cycle according to the changes in the plasma parameters, such as density and temperature. The fast-ion losses are also identified using orbit following simulations, allowing us to distinguish the different contributions to the FILD signal. The pre-ELM AEs’ frequencies and the velocity-space of the MHD-induced fast-ion losses are preserved on the FILD signal during the first ∼800 microseconds of the ELM crash, suggesting a complex interaction between AEs, fast ions and ELMs.
- 29 January 2026
- Published by IOP Publishing in Nuclear Fusion
- Vol. 66 (3) , 036009
Open AccessDynamics of the fast-ion acceleration in type-I ELMy H-mode scenarios on the TCV tokamak
Fast ions have been observed to be accelerated in the presence of Edge Localised Modes (ELMs) and MHD activity on the Tokamak á Configuration Variable. The acceleration time, velocity-space and frequency dynamics have been resolved by analysing the fast-ion losses measured using a unique Fast Ion Loss Detector (FILD) that allows microsecond velocity-space mapping. The findings presented herein complement and extend previous studies done at the Asdex Upgrade Tokamak and show a decorrelation between the acceleration and the ELM crash. The experimental scenario is a high-confinement mode (H-mode) plasma, characterised by low density, high electron temperature and, hence, long slowing down times of the fast-ion population. Significant MHD activity has been observed in the inter-ELM-crash period with frequencies ranging from 50 to 250 kHz. These modes exhibit strong down-chirping and burst signatures. The empirical dependence of the modes’ frequency upon the plasma density identifies them as Alfvén Eigenmodes (AEs) and locates them in the outer region of the plasma, where the resonance conditions between the fast ions and modes are fulfilled. Their resonant interaction with the fast-ion, generated using a Neutral Beam Injector, changes during the ELM cycle according to the changes in the plasma parameters, such as density and temperature. The fast-ion losses are also identified using orbit following simulations, allowing us to distinguish the different contributions to the FILD signal. The pre-ELM AEs’ frequencies and the velocity-space of the MHD-induced fast-ion losses are preserved on the FILD signal during the first ∼800 microseconds of the ELM crash, suggesting a complex interaction between AEs, fast ions and ELMs.
- Open Access
- 14 October 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (11) , 114001
First velocity-space resolved measurements of relativistic electron losses in a magnetically confined plasma
This letter reports on the first direct velocity-space resolved measurements of runaway electrons (REs) losses in magnetically confined plasmas using a unique Fast Particle Loss Detector (FPLD) installed on the magnetic confinement fusion device Tokamak à Configuration Variable. Clear signatures of REs are identified via multiple distinct regions of emission appearing on the FPLD scintillator-coated plate in plasma discharges that contain no fast ions but are characterised by significant RE populations, as monitored through measurements of gamma-ray emission. Some of these regions of emission on the FPLD scintillator result from direct impacts of REs that have passed, virtually unimpeded, through one of the FPLD’s steel collimators. These RE impacts correspond to a region of momentum space centred around a pitch, λ = v ∥ / v ∼ ± 0.8 and energy, E ∼ 3 MeV. Simultaneous measurements of both co- and counter-current RE losses provide evidence for the detection of both passing and trapped REs. Full-orbit and Monte Carlo simulations of the interaction of the REs with the FPLD components indicate that a fraction of the REs can pass through the FPLD’s collimator or through its graphite shielding, leading to multiple emission locations on the scintillator plate, with both features observed experimentally.
- 14 October 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (11) , 114001
Open AccessFirst velocity-space resolved measurements of relativistic electron losses in a magnetically confined plasma
This letter reports on the first direct velocity-space resolved measurements of runaway electrons (REs) losses in magnetically confined plasmas using a unique Fast Particle Loss Detector (FPLD) installed on the magnetic confinement fusion device Tokamak à Configuration Variable. Clear signatures of REs are identified via multiple distinct regions of emission appearing on the FPLD scintillator-coated plate in plasma discharges that contain no fast ions but are characterised by significant RE populations, as monitored through measurements of gamma-ray emission. Some of these regions of emission on the FPLD scintillator result from direct impacts of REs that have passed, virtually unimpeded, through one of the FPLD’s steel collimators. These RE impacts correspond to a region of momentum space centred around a pitch, λ = v ∥ / v ∼ ± 0.8 and energy, E ∼ 3 MeV. Simultaneous measurements of both co- and counter-current RE losses provide evidence for the detection of both passing and trapped REs. Full-orbit and Monte Carlo simulations of the interaction of the REs with the FPLD components indicate that a fraction of the REs can pass through the FPLD’s collimator or through its graphite shielding, leading to multiple emission locations on the scintillator plate, with both features observed experimentally.
- Open Access
- 8 August 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (9)
First measurements of velocity-space resolved intra-ELM fast-ion losses on the TCV tokamak
Edge Localised Modes (ELM) induced fast-ion losses have been characterised in the energy, E, and pitch, λ= v∥/v, space using a unique Fast Ion Loss Detector (FILD) on the Tokamak à Configuration Variable (TCV). The FILD is equipped with a 128 Avalanche Photo Diodes (APDs) camera measuring scintillator emission with a 1MHz bandwidth. The well-defined view lines of the APDs allow for obtaining velocity space information from the emission pattern with unrepresented temporal resolution. Making use of the enhanced FILD capabilities, ELM-induced fast-ion losses were investigated in the ITER Baseline Scenario, mimicking its shape and normalised plasma parameters. Significant fast-ion losses were observed, notably before and during the ELM crashes induced by the presence of a 2/1 MHD instability localised at the plasma’s normalised radius, p = 0.7. The fast-ion interaction with the plasma instabilities is concluded to be unconnected to the presence of the ELMs. During the ELM crashes, there is an observed spread in both the fast-ion pitch and energy that reaches higher values (~75 keV) than expected from the pre-ELM fast-ion population, generated by Neutral Beam Injection at ~27 keV. This implies a fast-ion acceleration during the ELM’s crash. Full orbit neoclassical simulations are used to calculate the neoclassical fast-ion velocity space lost to the FILD and to quantify the neoclassical fast-ion losses.
- 8 August 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (9)
Open AccessFirst measurements of velocity-space resolved intra-ELM fast-ion losses on the TCV tokamak
Edge Localised Modes (ELM) induced fast-ion losses have been characterised in the energy, E, and pitch, λ= v∥/v, space using a unique Fast Ion Loss Detector (FILD) on the Tokamak à Configuration Variable (TCV). The FILD is equipped with a 128 Avalanche Photo Diodes (APDs) camera measuring scintillator emission with a 1MHz bandwidth. The well-defined view lines of the APDs allow for obtaining velocity space information from the emission pattern with unrepresented temporal resolution. Making use of the enhanced FILD capabilities, ELM-induced fast-ion losses were investigated in the ITER Baseline Scenario, mimicking its shape and normalised plasma parameters. Significant fast-ion losses were observed, notably before and during the ELM crashes induced by the presence of a 2/1 MHD instability localised at the plasma’s normalised radius, p = 0.7. The fast-ion interaction with the plasma instabilities is concluded to be unconnected to the presence of the ELMs. During the ELM crashes, there is an observed spread in both the fast-ion pitch and energy that reaches higher values (~75 keV) than expected from the pre-ELM fast-ion population, generated by Neutral Beam Injection at ~27 keV. This implies a fast-ion acceleration during the ELM’s crash. Full orbit neoclassical simulations are used to calculate the neoclassical fast-ion velocity space lost to the FILD and to quantify the neoclassical fast-ion losses.
- Open Access
- 6 August 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (9) , 092002
Isotope effects in linear and saturated ohmic confinement of TCV tokamak and gyrokinetic validation
We investigated isotope effects during the tokamak à configuration variable (TCV) ohmic discharge of a diverted positive triangular shape configuration of deuterium (D) and hydrogen (H) plasmas. The transition from the linear ohmic confinement (LOC) regime to the saturated ohmic confinement (SOC) regime was clearly identified from the shot-by-shot density scan experiments. The transport characteristics were almost identical in the H and D plasmas in the LOC regime, and clear improvements were observed in the heat and particle transports in the D plasma compared with the H plasma in the SOC regime. In the SOC regime, the global energy confinement was higher in the D plasma than in the H plasma. Improvements in the SOC regime were evident in the ion channel of the heat transport and the diffusion term of the particle transport. Intrinsic toroidal rotation was found. Its profiles were identical in the H and D plasma in the LOC regime. However, the steeper gradient of toroidal rotation was found in the D plasma than in the H plasma in the SOC regime. The gyrokinetic modeling of switching ion species and keeping identical input profiles showed no difference of the heat flux in the LOC regime and a clear reduction in the D plasma heat flux in the SOC regime. Additionally, collisionality is shown to play an important role in in the heat flux reduction in D plasmas relative to H plasmas. The gyrokinetic validation of the heat transport against the experimental profiles showed a qualitative agreement regarding the heat and particle fluxes. Quantitative agreement was better for the ion heat channel than for the other transport channels.
- 6 August 2025
- Published by IOP Publishing in Nuclear Fusion
- Vol. 65 (9) , 092002
Open AccessIsotope effects in linear and saturated ohmic confinement of TCV tokamak and gyrokinetic validation
We investigated isotope effects during the tokamak à configuration variable (TCV) ohmic discharge of a diverted positive triangular shape configuration of deuterium (D) and hydrogen (H) plasmas. The transition from the linear ohmic confinement (LOC) regime to the saturated ohmic confinement (SOC) regime was clearly identified from the shot-by-shot density scan experiments. The transport characteristics were almost identical in the H and D plasmas in the LOC regime, and clear improvements were observed in the heat and particle transports in the D plasma compared with the H plasma in the SOC regime. In the SOC regime, the global energy confinement was higher in the D plasma than in the H plasma. Improvements in the SOC regime were evident in the ion channel of the heat transport and the diffusion term of the particle transport. Intrinsic toroidal rotation was found. Its profiles were identical in the H and D plasma in the LOC regime. However, the steeper gradient of toroidal rotation was found in the D plasma than in the H plasma in the SOC regime. The gyrokinetic modeling of switching ion species and keeping identical input profiles showed no difference of the heat flux in the LOC regime and a clear reduction in the D plasma heat flux in the SOC regime. Additionally, collisionality is shown to play an important role in in the heat flux reduction in D plasmas relative to H plasmas. The gyrokinetic validation of the heat transport against the experimental profiles showed a qualitative agreement regarding the heat and particle fluxes. Quantitative agreement was better for the ion heat channel than for the other transport channels.
- Open Access
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Design and upgrades of the TCV fast ion loss detector
The Tokamak à Configuration Variable has a unique Fast Ion Loss Detector (FILD) that allows the simultaneous measurement of co- and counter-current fast-ion losses in forward or reverse magnetic field. Recently, multiple novel upgrades have been implemented that further extended its capabilities. The optical system throughput was improved by adding anti-reflective coatings to the internal components, in direct view of the camera, and installing a low wavelength filter to reduce unwanted stray light. The mechanical rigidity was increased by adding additional contact points closer to the heat shield, which significantly reduced the system vibration amplitude during operation. The entrance slit pinholes were reduced from 1 to 0.8 mm, obtaining an energy resolution improvement of over 40% for only an ∼20% signal level decrease. Finally, a rotary system now permits the FILD head angle to be scanned from ±30° on a shot-to-shot basis. These upgrades, described herein, greatly increase the functionality of the FILD diagnostic.
- 1 August 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (8)
Open AccessDesign and upgrades of the TCV fast ion loss detector
The Tokamak à Configuration Variable has a unique Fast Ion Loss Detector (FILD) that allows the simultaneous measurement of co- and counter-current fast-ion losses in forward or reverse magnetic field. Recently, multiple novel upgrades have been implemented that further extended its capabilities. The optical system throughput was improved by adding anti-reflective coatings to the internal components, in direct view of the camera, and installing a low wavelength filter to reduce unwanted stray light. The mechanical rigidity was increased by adding additional contact points closer to the heat shield, which significantly reduced the system vibration amplitude during operation. The entrance slit pinholes were reduced from 1 to 0.8 mm, obtaining an energy resolution improvement of over 40% for only an ∼20% signal level decrease. Finally, a rotary system now permits the FILD head angle to be scanned from ±30° on a shot-to-shot basis. These upgrades, described herein, greatly increase the functionality of the FILD diagnostic.