A. Utrobicic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
A. Utrobicic has a total of 122 co-authors. Here are the top co-authors by number of shared publications:
A. Pandey
14 Faculty of Electrical Engineering and Computing, University of Zagreb, 10000 Zagreb, Croatia
6 shared publications- Davide Fiorina
INFN Sezione di Pavia
6 shared publications - Francisco Garcia
Helsinki Institute of Physics
6 shared publications - Francisco José Iguaz
Irfu, CEA, Université Paris-Saclay, F-91191 Gif-sur-Yvette, France
6 shared publications - Ilaria Vai
Università di Pavia
6 shared publications J. McKisson
13 Jefferson Lab, Newport News, VA 23606, U.S.A.
6 shared publications
Latest Publications
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04019
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couples a Cherenkov radiator, typically an MgF 2 crystal, to a Micromegas-based photodetector equipped with a photocathode, allowing the fast photoelectron-induced signal to suppress the intrinsic time jitter characteristic of gaseous detectors. This design enables sub-20 ps timing precision while preserving the robustness and scalability of Micro-Pattern Gaseous Detector (MPGD) technologies. The 96-pad PICOSEC-MM detector represents the latest advancement in this development, optimized for precision timing in high-energy physics. Building upon the R&D insights obtained with earlier 7-pad resistive prototypes, this large-area demonstrator was developed to validate the scalability, uniformity, and robustness of the technology for integration into the ENUBET project. The detector employs a 2.5 nm Diamond-Like Carbon (DLC) photocathode with a Micromegas board equipped with surface resistivity of 10 MΩ/□, providing an excellent timing performance. The prototype was characterized using 150 GeV/ c muons at the CERN SPS beamline, with one-third of the active area instrumented during each run. A dedicated alignment procedure, developed for multi-pad PICOSEC-MM systems, was used to reconstruct the pad centers and combine measurements across different detector regions. The measured timing resolution was 43 ps across the instrumented pads, while the Signal Arrival Time (SAT) distributions exhibited a good uniformity among the detector area that was tested. Mechanical flatness was identified as a key factor influencing timing precision. Maintaining a planarity tolerance within 10 μm is therefore critical to preserve a good timing resolution over large active areas. The successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept marking a significant step toward implementing robust, high-granularity, picosecond-level gaseous timing detectors in monitored neutrino beam experiments such as ENUBET.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04019
Open AccessDesign and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couples a Cherenkov radiator, typically an MgF 2 crystal, to a Micromegas-based photodetector equipped with a photocathode, allowing the fast photoelectron-induced signal to suppress the intrinsic time jitter characteristic of gaseous detectors. This design enables sub-20 ps timing precision while preserving the robustness and scalability of Micro-Pattern Gaseous Detector (MPGD) technologies. The 96-pad PICOSEC-MM detector represents the latest advancement in this development, optimized for precision timing in high-energy physics. Building upon the R&D insights obtained with earlier 7-pad resistive prototypes, this large-area demonstrator was developed to validate the scalability, uniformity, and robustness of the technology for integration into the ENUBET project. The detector employs a 2.5 nm Diamond-Like Carbon (DLC) photocathode with a Micromegas board equipped with surface resistivity of 10 MΩ/□, providing an excellent timing performance. The prototype was characterized using 150 GeV/ c muons at the CERN SPS beamline, with one-third of the active area instrumented during each run. A dedicated alignment procedure, developed for multi-pad PICOSEC-MM systems, was used to reconstruct the pad centers and combine measurements across different detector regions. The measured timing resolution was 43 ps across the instrumented pads, while the Signal Arrival Time (SAT) distributions exhibited a good uniformity among the detector area that was tested. Mechanical flatness was identified as a key factor influencing timing precision. Maintaining a planarity tolerance within 10 μm is therefore critical to preserve a good timing resolution over large active areas. The successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept marking a significant step toward implementing robust, high-granularity, picosecond-level gaseous timing detectors in monitored neutrino beam experiments such as ENUBET.
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03015
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector concept was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 × 10 cm2 area prototypes and a 20 × 20 cm2 prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.
- 1 March 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (03) , C03015
PICOSEC Micromegas precise-timing detectors: development towards large-area application and integration
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector concept was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 × 10 cm2 area prototypes and a 20 × 20 cm2 prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.
- Open Access
- 11 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
- 11 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Open AccessPhotocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
- Open Access
- 16 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
- 16 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessPICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging