Han Van Bladel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Han Van Bladel has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Wout Joseph
Ghent University/IMEC
3 shared publications - Adriana Fernandes Veludo
Swiss Tropical and Public Health Institute, Allschwil, Switzerland; University of Basel, Basel, Switzerland
2 shared publications - Bram Stroobandt
Department of Information Technology, Ghent University / imec, 9052 Ghent, Belgium
2 shared publications - Kenneth Deprez
Department of Information Technology, IMEC, Ghent University, Ghent, Belgium
2 shared publications - Martin Röösli
Swiss Tropical and Public Health Institute, Allschwil, Switzerland
2 shared publications Mònica Guxens
ISGlobal, Barcelona, Spain; Universitat Pompeu Fabra, Barcelona, Spain; Spanish Consortium for Research on Epidemiology and Public Health (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain; Department of Child and Adolescent Psychiatry/Psychology, Erasmus MC, University Medical Centre, Rotterdam, the Netherlands; ICREA, Barcelona, Spain
2 shared publications
Latest Publications
- Open Access
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 16050-16060
Design and Validation of a Low-Cost Triaxial 5G RF-EMF Exposure Sensor
A low-cost monitoring network, to measure radio frequency electromagnetic field exposure induced by 5G, is required for risk communication and to support research into long-term health and ecological effects related to 5G technologies. A low-cost triaxial 5G RF-EMF exposure sensor was designed, calibrated, and validated in the field, using a commercial network. The sensor uses a triaxial antenna based measurement design and is able to measure the exposure induced by 5G communication in the n78 (3300-3800 MHz) and the n77 (3300-4200 MHz) frequency band up to 3900 MHz. The sensitivity of the simultaneous ADC based triaxial sensor is 0.06 V/m, while having a combined uncertainty uc of 3.12 dB. The sensor was tested indoor and in two outdoor environments (private and commercial 5G network). The maximum measured electric-field level induced by 5G (n77 band) was 0.89 V/m (500 m from a commercial base station) and 2.87 V/m (60 m from a private base station), which are 1.5% and 4.8% of the ICNIRP guidelines, respectively. A second measurement campaign was used to compare the values of the electric field captured by the novel triaxial 5G sensor and commercial measurement equipment (SRM-3006). The average values of the electric field registered by the triaxial 5G sensor differ on average 2.8 dB from the values of the SRM-3006, which is within the measurement uncertainty of the SRM-3006.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 16050-16060
Open AccessDesign and Validation of a Low-Cost Triaxial 5G RF-EMF Exposure Sensor
A low-cost monitoring network, to measure radio frequency electromagnetic field exposure induced by 5G, is required for risk communication and to support research into long-term health and ecological effects related to 5G technologies. A low-cost triaxial 5G RF-EMF exposure sensor was designed, calibrated, and validated in the field, using a commercial network. The sensor uses a triaxial antenna based measurement design and is able to measure the exposure induced by 5G communication in the n78 (3300-3800 MHz) and the n77 (3300-4200 MHz) frequency band up to 3900 MHz. The sensitivity of the simultaneous ADC based triaxial sensor is 0.06 V/m, while having a combined uncertainty uc of 3.12 dB. The sensor was tested indoor and in two outdoor environments (private and commercial 5G network). The maximum measured electric-field level induced by 5G (n77 band) was 0.89 V/m (500 m from a commercial base station) and 2.87 V/m (60 m from a private base station), which are 1.5% and 4.8% of the ICNIRP guidelines, respectively. A second measurement campaign was used to compare the values of the electric field captured by the novel triaxial 5G sensor and commercial measurement equipment (SRM-3006). The average values of the electric field registered by the triaxial 5G sensor differ on average 2.8 dB from the values of the SRM-3006, which is within the measurement uncertainty of the SRM-3006.
- Open Access
- 3 February 2025
- Published by Elsevier in Environmental Research
- Vol. 270, 121029
Auto-induced uplink 4G and 5G RF-EMF exposure assessment using a network monitoring application in different microenvironments across seven European countries
- 3 February 2025
- Published by Elsevier in Environmental Research
- Vol. 270, 121029
Open AccessAuto-induced uplink 4G and 5G RF-EMF exposure assessment using a network monitoring application in different microenvironments across seven European countries
- Open Access
- 5 December 2024
- Published by Elsevier in Environmental Research
- Vol. 266, 120550
Exploring RF-EMF levels in Swiss microenvironments: An evaluation of environmental and auto-induced downlink and uplink exposure in the era of 5G
- 5 December 2024
- Published by Elsevier in Environmental Research
- Vol. 266, 120550
Open AccessExploring RF-EMF levels in Swiss microenvironments: An evaluation of environmental and auto-induced downlink and uplink exposure in the era of 5G