KZKrzysztof Zawalski

Krzysztof Zawalski

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Krzysztof Zawalski has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Intelligent Robot-Aided, Task-Oriented Physiotherapy Method for Upper Limb Rehabilitation: Development and Usability Study

    by Piotr Falkowski, Kajetan Jeznach, Jan Oleksiuk, Tomasz Osiak, Maciej Pikuliński, Andrzej ZakręCki, Krzysztof Zawalski, Piotr Kołodziejski, Daniel Śliż

    Background: Task-oriented rehabilitation supported by exoskeletons has the potential to increase therapy intensity, personalization, and accessibility. However, to achieve fully automatic treatment, robotized systems need to analyze therapy in a more complex way than only based on reference trajectories following. Objective: This study aimed to investigate the effects of an intelligent, context-aware control algorithm for an upper limb rehabilitation exoskeleton on patients’ musculoskeletal engagement, compared with constant-admittance robot-assisted therapy, and conventional physiotherapist-guided treatment. Methods: A single-session experimental study was conducted with 34 adult participants performing 6 activities of daily living under 3 therapy modes: robot-assisted therapy with constant admittance, robot-assisted therapy with an intelligent assist-as-needed algorithm, and physiotherapist-guided therapy. Muscle activity was assessed using surface electromyography of 8 upper limb muscle groups, while joint kinematics were recorded using inertial measurement units. Metrics included electromyography power, muscle activation time, joint range of motion, and Burst Duration Similarity Indices. Statistical comparisons were performed using the t test and the Mann-Whitney U test depending on data normality. Results: Results indicate that the intelligent control strategy engages the musculoskeletal system at least as effectively as constant-admittance control across all exercises. At the same time, more motion control is given to the patient, which is consistent with the principles of neuroplastic motor learning. Compared with physiotherapist-guided therapy, robot-assisted treatment with intelligent control elicited significantly higher and more consistent muscular engagement. Intelligent assistance also modified joint-level motion patterns by reducing compensatory movements, particularly in shoulder-elbow coupling, while maintaining functional task execution. Muscle activation timing patterns during intelligent robot-assisted therapy were more consistent with robotic control than with manual therapy, reflecting altered movement strategies. Conclusions: These findings demonstrate that context-aware, intelligent control in rehabilitation exoskeletons can promote active patient participation, reduce compensatory behaviors, and maintain physiologically meaningful muscle engagement. The proposed approach exceeds the results of recent similar studies, being a promising step toward effective, minimally supervised, and task-oriented rehabilitation.

  • Open Access

    Method for Improving Muscular Activations during Exoskeleton-Aided Therapy with Intelligent Algorithms and VR-Based Teleoperation

    by Piotr Falkowski, Kajetan Jeznach, Tomasz Osiak, Jan Oleksiuk, Krzysztof Zawalski, Piotr Kołodziejski, Daniel Śliż, Zbigniew Pilat, Tomasz Chomiuk

    Population ageing, neurological and orthopaedical diseases, and shortages in medical staff result in the need to develop tools for minimally su-pervised therapy. To guarantee effective kinesiotherapy in high doses, rehabilitation robots are required. However, they require additional tech-nologies for automating treatment and monitoring patients' safety. This paper presents and assesses such technologies integrated with the SmartEx-Twin exoskeleton of a lower extremity and its digital twin in virtual reality (VR) for teleoperation during emergency cases. The intelligent algorithms were proven to increase the effectiveness of the therapy, as assessed based on the EMG measured. The VR system was validated as also increasing the effectiveness, but reducing the perception of tiring exercises, based on EEG tracking. Additionally, the accuracy of controlling exoskeleton movements was measured. It was found out that the poor operation skills of the physiotherapist in the VR environment can increase motion inaccuracies by as much as 30 degrees per joint. Additional emergency tools trig-gered by spastic cramps detected and risk of pain were assessed as fully reliable and working with the delay of up to 125 ms and 2 s, respec-tively. The whole system was implemented for the exoskeleton and will undergo further tests to minimize control inaccuracies and teleoperation delays.

  • Open Access

    Measurement-Based Optimization of a Lightweight Upper-Extremity Rehabilitation Exoskeleton for Task-Oriented Treatment

    by Piotr Falkowski, Piotr Kołodziejski, Krzysztof Zawalski, Maciej Pikuliński, Jan Oleksiuk, Tomasz Osiak, Andrzej ZakręCki, Kajetan Jeznach, Daniel Śliż

    Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients with neurological conditions, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons—wearable devices that mobilize multiple joints with complex motions representing activities of daily living. To perform kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology for decreasing the mass of the exoskeleton design with real-life data-driven simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% for the main construction elements while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all components. The final design was manufactured and tested with humans, reflecting an almost fully automatic passive and active therapy.


  • Rehabilitation Exoskeleton's Motion Monitoring Based on the Multibody Model Simulation Compared to the IMU-Based Digital Shadow

    by Piotr Falkowski, Jan Oleksiuk, Krzysztof Zawalski, Kajetan Jeznach, Piotr Kołodziejski

    Due to the aging of the population, the need for rehabilitation devices has risen, including rehabilitation exoskeletons. The exoskeletons combined with digital shadows can be used for providing therapy and monitoring it, also with minimal supervision. This study aimed to evaluate the accuracy of multibody model simulations based on encoder measurements compared with IMU-based digital shadows for monitoring an upper extremity physiotherapy with such devices. The SmartEx-Home exoskeleton was used as the test platform. Encoder readings were applied to a multibody dynamics model in MATLAB/Simulink, while IMU sensors recorded construction segments' orientations. Both methods were tested with executing task-oriented motion registered by a physiotherapist. Results showed that encoders measured angular inaccuracies between registered and followed joint trajectories not exceeding 0.8 degrees and positional inaccuracies not exceeding 7.9 mm for the modeled center of the hand grip. IMU-based monitoring detected higher angular inaccuracies - up to 8.6 degrees, resulting in positional inaccuracies not higher than 12 mm. However, both methods differed by no more than 1.8 cm in monitoring of characteristic points, which remains within the tolerance of functionality of activities of daily living. In conclusion, encoder-based multibody simulations are more robust and less noise-prone, while IMU-based systems capture structural deformations. Both methods are suitable for digital shadow applications in rehabilitation, but encoder-driven models are preferable for automatic motion assessment, especially while operating with low deviations of construction segments.

  • Open Access

    Optimization-Based Design of a Lightweight Rehabilitation Exoskeleton of an Upper Extremity for Task-Oriented Treatment

    by Piotr Falkowski, Piotr Kołodziejski, Krzysztof Zawalski, Maciej Pikuliński, Jan Oleksiuk, Tomasz Osiak, Andrzej Zakręcki, Kajetan Jeznach, Daniel Śliż

    Contemporary physiotherapy requires technological tools to provide effective therapy to the increasing group of patients, neurological, among others. This can be achieved with rehabilitation robots, which can also be exoskeletons - wearable devices mobilizing multiple joints with complex motions representing activities of daily living. To perform the kinesiotherapy conveniently in home-like environments, the exoskeletons need to be relatively lightweight. The paper presents the methodology of decreasing the mass of the exoskeleton design with the human-in-the-loop simulations of motions, followed by multibody dynamics simulations, and finite element method (FEM) multistep optimization. The process includes sequential initial parametric optimization, topology optimization, and final parametric optimization. The steps are used to set initial dimensional and material parameters, extract new geometrical features, and adjust the final geometry dimensions of a new design. The presented case of the SmartEx-Home exoskeleton resulted in a total mass reduction of almost 50% while meeting the criteria of the minimum safety factor and maximum internal stress and strain for all the components. The final design is being manufactured and will be used within the tests with humans, reflecting almost fully automatic passive and active therapy.

  • Open Access

    Multibody Dynamics Simulation of Upper Extremity Rehabilitation Exoskeleton During Task-Oriented Exercises

    by Piotr Falkowski, Krzysztof Zawalski

    Population aging intensifies the demand for rehabilitation services, which are already suffering from staff shortages. In response to this challenge, the implementation of new technologies in physiotherapy is needed. For such a task, rehabilitation exoskeletons can be used. While designing such tools, their functionality and safety must be ensured. Therefore, simulations of their strength and kinematics must meet set criteria. This paper aims to present a methodology for simulating the dynamics of rehabilitation exoskeletons during activities of daily living and determining the reactions in the construction’s joints, as well as the required driving torques. The methodology is applied to the SmartEx-Home exoskeleton. Two versions of a multibody model were developed in the Matlab/Simulink environment—a rigid-only version and one with deformable components. The kinematic chain of construction was reflected with the driven rotational joints and modeled passive sliding open bearings. The simulation outputs include the driving torques and joint reaction forces and the torques for various input trajectories registered using IMU sensors on human participants. The results obtained in the investigation show that in general, to mobilize shoulder flexion/extension or abduction/adduction, around 30 Nm of torque is required in such a lightweight exoskeleton. For elbow flexion/extension, around 10 Nm of torque is needed. All of the reactions are presented in tables for all of the characteristic points on the passive and active joints, as well as the attachments of the extremities. This methodology provides realistic load estimations and can be universally used for similar structures. The presented numerical results can be used as the basis for a strength analysis and motor or force sensor selection. They will be directly implemented for the process of mass minimization of the SmartEx-Home exoskeleton based on computational optimization.


  • Open Access

    Similarity Analysis of Upper Extremity’s Trajectories in Activities of Daily Living for Use in an Intelligent Control System of a Rehabilitation Exoskeleton

    by Piotr Falkowski, Maciej Pikuliński, Tomasz Osiak, Kajetan Jeznach, Krzysztof Zawalski, Piotr Kołodziejski, Andrzej Zakręcki, Jan Oleksiuk, Daniel Śliż, Natalia Osiak

    Rehabilitation robotic systems have been developed to perform therapy with minimal supervision from a specialist. Hence, they require algorithms to assess and support patients’ motions. Artificial intelligence brings an opportunity to implement new exercises based on previously modelled ones. This study focuses on analysing the similarities in upper extremity movements during activities of daily living (ADLs). This research aimed to model ADLs by registering and segmenting real-life movements and dividing them into sub-tasks based on joint motions. The investigation used IMU sensors placed on the body to capture upper extremity motion. Angular measurements were converted into joint variables using Matlab computations. Then, these were divided into segments assigned to the sub-functionalities of the tasks. Further analysis involved calculating mathematical measures to evaluate the similarity between the different movements. This approach allows the system to distinguish between similar motions, which is critical for assessing rehabilitation scenarios and anatomical correctness. Twenty-two ADLs were recorded, and their segments were analysed to build a database of typical motion patterns. The results include a discussion on the ranges of motion for different ADLs and gender-related differences. Moreover, the similarities and general trends for different motions are presented. The system’s control algorithm will use these results to improve the effectiveness of robotic-assisted physiotherapy.


  • Investigation of Delays and Connection Stability in Teleoperation via VR Capabilities for Remote Exoskeleton-Aided Physiotherapy

    by Piotr Falkowski, Krzysztof Zawalski, Kajetan Jeznach, Jan Oleksiuk, Mehmet Emin Aktan, Vasfi Emre Ömürlü, Paweł Niedbalski, Erhan Akdoğan, Piotr Kołodziejski

    The research paper examines the challenges of remote control delays in exoskeleton-aided physiotherapy. It focuses on the implications of telerehabilitation requirements for safe treatment. As the global share of disabled and elderly people increases, the demand for effective teleoperated physiotherapy solutions rises, necessitating precise control over robotic systems. The study utilizes a mixed-methods approach to assess delays in communication between a rehabilitation exoskeleton and the control system's based on the digital twin in VR (virtual reality) components at different stages. Moreover, additional delays coming from distant operations are assessed. Key findings reveal that the average latency for joint control on shorter distances remains below 300 ms-considered acceptable for comfortable manual teleoperation. The delays between setting the device's configuration and reaching it by a physical exoskeleton differ for particular joints and depend mainly on the torque-to-moment of inertia ratio. The total communication cycle should not exceed 400 ms, which can be further reduced by using a 6G network in the future or ADS (Automation Device Specification) communication protocol instead of the database. Ultimately, the study provides a foundation for developing algorithms that can mitigate delays and improve the efficacy of telehealth solutions with physically supportive devices.


  • Open Access

    Systematic review of mechanical designs of rehabilitation exoskeletons for lower-extremity

    by Krzysztof Zawalski, Jan Oleksiuk, Piotr Falkowski, Bazyli Leczkowski, Zbigniew Pilat, Mehmet Emin Aktan, Erhan Akdogan, Paweł Niedbalski, Maciej Mazowiec, Mateusz Wawrzyniak, et al.

    Exoskeletons of lower extremities are used mainly for gait treatment in physical rehabilitation. However, they are also capable of being involved in other types of exercises. Nevertheless, their structure needs to be adequately adjusted for such applications. To analyse approaches to that, this review paper investigates the mechanical designs of rehabilitation exoskeletons for lower extremities. The study seeks to identify best practices in designing and implementing these devices by analysing fifty-two articles. It covers aspects such as kinematic structures, materials used, types of drives, and the range of exercises. Standard design features include multiple degrees of freedom, primarily at the hip, knee, and ankle joints, and using lightweight materials to enhance mobility and reduce power consumption. The review also discusses the advantages of different driving systems. The findings provide valuable insights for developing effective and safe rehabilitation exoskeletons, contributing to improved patient outcomes in physiotherapy and rehabilitation settings.