Dmitrii A. Radko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dmitrii A. Radko has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Vitalii V. Danilov
Pacific State Medical University
4 shared publications - Vladimir V. Vashchenko
Pacific State Medical University
4 shared publications - A. K. Shalaeva
Pacific State Medical University
3 shared publications - I. Yu. Volnykh
Pacific State Medical University; RZD-Medicine Clinical Hospital
3 shared publications И. Ю. Вольных
Тихоокеанский государственный медицинский университет; Клиническая больница «РЖД-Медицина
3 shared publications- Valerii V. Danilov
Clinical Hospital RZD–Medicine; Far Eastern Federal University
1 shared publication
Latest Publications
- Open Access
- 12 December 2024
- Published by Immanuel Kant Baltic Federal University in Surgical Practice
- No. 4,p. 6-15
Changes in uroflowmetry indicators with automatic interference elimination
Aim. The aim of this article is to compare the values of measured (QMAX) and calculated (QMCLC) maximal urine flow and the values of measured (TQ) and calculated (TQCLC) time to reach maximal flow in a large group of individual uroflowgrams during home uroflowmetry.Materials and Methods. We analysed 29,110 individual uroflowgrams from 719 patients with prostate adenoma, aged 50 to 73 years (mean age, 60.5 ± 8.2 years), collected between 2004 and 2024. Two algorithms were used: determination of QMAX as the maximum value of the calculated flow (function extremum) and calculation of the actual value of the maximum flow after computer processing to eliminate interference and the WAG-effect (QMCLC).Results. The data showed the following differences between QMAX and QMCLC in the groups: 16.14 % for volumes up to 100 ml; 14.62 % for 100–200 ml; 13.75 % for 200–300 ml; 13.04 % for 300–400 ml; 14.25 % for 400–500 ml; 14.55 % for 500–600 ml; and 12.65 % for 600+ ml. For TQ and TQCLC values, the group differences were as follows: 3.49 % for volumes up to 100 mL; 2.27 % for 100–200 mL; 0.71 % for 200–300 mL; 0.97 % for 300–400 mL; 0.91 % for 400–500 mL; 3.51 % for 500–600 mL; and 1.51 % for 600+ mL.Conclusion. The study demonstrated a statistically significant difference between the maximum urine flow (QMAX) values obtained during measurement and the maximum urine flow value, after removing interference and the WAG effect (QMCLS) characteristic of any recorded volumes. Therefore, the accuracy of the data obtained may differ depending on the algorithm of uroflowgram processing. No statistically significant difference was found between TQ and TQCLC parameters. The algorithm of uroflowgrams processing used in the Sigma and Urovest uroflowmetry hardware and software system ensures high accuracy in determining maximum flow values; Urovest, in particular, has demonstrated reliability in this regard. The average determined difference between the QMAX and QMCLC values at different volumes of urination is 14.14 %.
- 12 December 2024
- Published by Immanuel Kant Baltic Federal University in Surgical Practice
- No. 4,p. 6-15
Open AccessChanges in uroflowmetry indicators with automatic interference elimination
Aim. The aim of this article is to compare the values of measured (QMAX) and calculated (QMCLC) maximal urine flow and the values of measured (TQ) and calculated (TQCLC) time to reach maximal flow in a large group of individual uroflowgrams during home uroflowmetry.Materials and Methods. We analysed 29,110 individual uroflowgrams from 719 patients with prostate adenoma, aged 50 to 73 years (mean age, 60.5 ± 8.2 years), collected between 2004 and 2024. Two algorithms were used: determination of QMAX as the maximum value of the calculated flow (function extremum) and calculation of the actual value of the maximum flow after computer processing to eliminate interference and the WAG-effect (QMCLC).Results. The data showed the following differences between QMAX and QMCLC in the groups: 16.14 % for volumes up to 100 ml; 14.62 % for 100–200 ml; 13.75 % for 200–300 ml; 13.04 % for 300–400 ml; 14.25 % for 400–500 ml; 14.55 % for 500–600 ml; and 12.65 % for 600+ ml. For TQ and TQCLC values, the group differences were as follows: 3.49 % for volumes up to 100 mL; 2.27 % for 100–200 mL; 0.71 % for 200–300 mL; 0.97 % for 300–400 mL; 0.91 % for 400–500 mL; 3.51 % for 500–600 mL; and 1.51 % for 600+ mL.Conclusion. The study demonstrated a statistically significant difference between the maximum urine flow (QMAX) values obtained during measurement and the maximum urine flow value, after removing interference and the WAG effect (QMCLS) characteristic of any recorded volumes. Therefore, the accuracy of the data obtained may differ depending on the algorithm of uroflowgram processing. No statistically significant difference was found between TQ and TQCLC parameters. The algorithm of uroflowgrams processing used in the Sigma and Urovest uroflowmetry hardware and software system ensures high accuracy in determining maximum flow values; Urovest, in particular, has demonstrated reliability in this regard. The average determined difference between the QMAX and QMCLC values at different volumes of urination is 14.14 %.
- Open Access
- 16 July 2024
- Published by Immanuel Kant Baltic Federal University in Surgical Practice
- No. 2,p. 6-21
Optimizing Treatment Strategies of Prostate Adenoma through Analytical Urodynamics
Aim: To investigate the role of urinary obstruction in determining surgical indications based on analytical urodynamics.Materials and methods. To collect observational data, a cohort of patients was selected from those receiving treatment at the Urination Pathology Centre in Vladivostok due to urinary disorders and prostate adenoma. This cohort consisted of patients aged 50 to 73 years (mean age 60.5 ± 8.2 years), with observation periods ranging from 2 to 29.3 months (mean duration 15.5 ± 13.5 months). During a two-day home uroflow monitoring session, the severity of urinary symptoms was assessed using the IPSS questionnaire prior to each monitoring event. The study utilized a domestically designed two-sensor SIGMA uroflowmeter in conjunction with LEVELEST software.Results. The study demonstrated that in patients from all three groups undergoing therapy with an alpha-1 adrenergic blocker, there was a significant reduction in clinical symptoms as measured by the IPSS questionnaire and an increase in the average effective volume of urination. However, despite these improvements, the groups exhibited differing dynamics in urinary obstruction, which ultimately determined the indications for surgical intervention.Conclusion. Home uroflow monitoring with the Sigma uroflowmeter provides an objective assessment of the lower urinary tract function in patients with bladder outlet obstruction, focusing on the urinary obstruction indicator dynamics. Repeated pharmacological testing in patients with prostate adenoma shows potential for long-term patient management, aiming to prevent detrusor failure and evaluate the efficacy of conservative therapy. Analytical urodynamic methods enable the establishment of surgical treatment indications based on uroflow monitoring outcomes.
- 16 July 2024
- Published by Immanuel Kant Baltic Federal University in Surgical Practice
- No. 2,p. 6-21
Open AccessOptimizing Treatment Strategies of Prostate Adenoma through Analytical Urodynamics
Aim: To investigate the role of urinary obstruction in determining surgical indications based on analytical urodynamics.Materials and methods. To collect observational data, a cohort of patients was selected from those receiving treatment at the Urination Pathology Centre in Vladivostok due to urinary disorders and prostate adenoma. This cohort consisted of patients aged 50 to 73 years (mean age 60.5 ± 8.2 years), with observation periods ranging from 2 to 29.3 months (mean duration 15.5 ± 13.5 months). During a two-day home uroflow monitoring session, the severity of urinary symptoms was assessed using the IPSS questionnaire prior to each monitoring event. The study utilized a domestically designed two-sensor SIGMA uroflowmeter in conjunction with LEVELEST software.Results. The study demonstrated that in patients from all three groups undergoing therapy with an alpha-1 adrenergic blocker, there was a significant reduction in clinical symptoms as measured by the IPSS questionnaire and an increase in the average effective volume of urination. However, despite these improvements, the groups exhibited differing dynamics in urinary obstruction, which ultimately determined the indications for surgical intervention.Conclusion. Home uroflow monitoring with the Sigma uroflowmeter provides an objective assessment of the lower urinary tract function in patients with bladder outlet obstruction, focusing on the urinary obstruction indicator dynamics. Repeated pharmacological testing in patients with prostate adenoma shows potential for long-term patient management, aiming to prevent detrusor failure and evaluate the efficacy of conservative therapy. Analytical urodynamic methods enable the establishment of surgical treatment indications based on uroflow monitoring outcomes.
- Open Access
- 22 March 2024
- Published by Immanuel Kant Baltic Federal University in Surgical Practice
- No. 1,p. 28-37
A method for determining incomplete urinary bladder emptying by uroflowmetry
Aim. This article aims to assess the effectiveness of uroflowmetry in detecting residual urine and to investigate the relationship between the sensation of incomplete bladder emptying, as measured by the IPSS questionnaire, and the presence of residual urine.Materials and methods. A cohort of patients treated at the Urination Pathology Centre (Vladivostok) for benign prostatic hyperplasia was observed and data were collected. Patients ranged in age from 50 to 73 years (with an average age of 60.5 ± 8.2 years) and were observed during from 2 to 24 months (with an average of 8.4 ± 5.5 months).Results. The analysis of ultrasound data and uroflowmetry results demonstrates convincingly that the SIGMA uroflowmeter can reliably detect residual urine with a high degree of accuracy (p < 0.01). However, during the study, no consistent correlation was found between the symptom of feeling of incomplete bladder emptying, as assessed by the IPSS questionnaire, and the presence of residual urine detected by the SIGMA uroflowmeter.Conclusion. Uroflowmetry conducted with the SIGMA uroflowmeter reliably identifies instances of incomplete bladder emptying, as evidenced by comparison with ultrasound data. At the same time, clinical assessment using the IPSS charts, particularly for the symptom of incomplete bladder emptying, does not adequately indicate the presence of residual urine. Uroflowmetry offers a means to identify incomplete bladder emptying and measure residual urine volume without requiring specialised equipment or medical personnel, thus broadening the diagnostic scope for both conservative and surgical treatment approaches.
- 22 March 2024
- Published by Immanuel Kant Baltic Federal University in Surgical Practice
- No. 1,p. 28-37
Open AccessA method for determining incomplete urinary bladder emptying by uroflowmetry
Aim. This article aims to assess the effectiveness of uroflowmetry in detecting residual urine and to investigate the relationship between the sensation of incomplete bladder emptying, as measured by the IPSS questionnaire, and the presence of residual urine.Materials and methods. A cohort of patients treated at the Urination Pathology Centre (Vladivostok) for benign prostatic hyperplasia was observed and data were collected. Patients ranged in age from 50 to 73 years (with an average age of 60.5 ± 8.2 years) and were observed during from 2 to 24 months (with an average of 8.4 ± 5.5 months).Results. The analysis of ultrasound data and uroflowmetry results demonstrates convincingly that the SIGMA uroflowmeter can reliably detect residual urine with a high degree of accuracy (p < 0.01). However, during the study, no consistent correlation was found between the symptom of feeling of incomplete bladder emptying, as assessed by the IPSS questionnaire, and the presence of residual urine detected by the SIGMA uroflowmeter.Conclusion. Uroflowmetry conducted with the SIGMA uroflowmeter reliably identifies instances of incomplete bladder emptying, as evidenced by comparison with ultrasound data. At the same time, clinical assessment using the IPSS charts, particularly for the symptom of incomplete bladder emptying, does not adequately indicate the presence of residual urine. Uroflowmetry offers a means to identify incomplete bladder emptying and measure residual urine volume without requiring specialised equipment or medical personnel, thus broadening the diagnostic scope for both conservative and surgical treatment approaches.