Eunji Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Eunji Kim has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Jae-Eun Kim
Department of Oral & Maxillofacial Surgery, College of Dentistry, Kyung Hee University, Seoul 02447, Republic of Korea
3 shared publications - Yong-Dae Kwon
Department of Oral and Maxillofacial Surgery, College of Dentistry, Kyung Hee University, Seoul, Korea
3 shared publications - Youngjae Yoon
Department of Oral & Maxillofacial Surgery, College of Dentistry, Kyung Hee University, Seoul 02447, Republic of Korea
3 shared publications - Inyeong Kang
School of Mechanical Engineering, Korea University, Seoul 02841, Republic of Korea
2 shared publications - Soyeon Park
School of Mechanical Engineering, Korea University, Seoul 02841, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 28 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12629
Influence of Morse Taper Angle and Bone Quality on the Biomechanical Behavior of Dental Implants: A Finite Element Analysis Study
This study performed a finite element analysis to evaluate the biomechanical effects of implant connection geometry and bone quality (D2, D4) on stress distribution and structural stability. A mandibular model consisting of cortical and cancellous bone was generated, and implant components—including fixture, abutment, screw, and crown—were simulated. Two designs were analyzed based on Morse taper angle (11° or 15°) and the presence of an apical slot. A tightening torque of 32 N·cm and an occlusal load of 200 N were applied, with the lateral mandible constrained. The 11° taper with the non-slot design showed the highest von Mises stress (1048.81 MPa) in the fixture with D4 bone type and Tessera crown. In contrast, the 15° taper with the slot design improved stress distribution at the fixture–abutment interface, reducing fixture stress by 26.78% in D2 bone type. Localized stress near the slot was observed but did not compromise overall structural stability. Under oblique loading, stress concentrated primarily in the cortical bone, whereas D4 cancellous bone showed increased susceptibility to microdamage. Prosthetic materials demonstrated no significant differences in stress behavior. These findings suggest that connection design and bone density strongly influence biomechanical performance and should guide individualized implant selection.
- 28 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12629
Open AccessInfluence of Morse Taper Angle and Bone Quality on the Biomechanical Behavior of Dental Implants: A Finite Element Analysis Study
This study performed a finite element analysis to evaluate the biomechanical effects of implant connection geometry and bone quality (D2, D4) on stress distribution and structural stability. A mandibular model consisting of cortical and cancellous bone was generated, and implant components—including fixture, abutment, screw, and crown—were simulated. Two designs were analyzed based on Morse taper angle (11° or 15°) and the presence of an apical slot. A tightening torque of 32 N·cm and an occlusal load of 200 N were applied, with the lateral mandible constrained. The 11° taper with the non-slot design showed the highest von Mises stress (1048.81 MPa) in the fixture with D4 bone type and Tessera crown. In contrast, the 15° taper with the slot design improved stress distribution at the fixture–abutment interface, reducing fixture stress by 26.78% in D2 bone type. Localized stress near the slot was observed but did not compromise overall structural stability. Under oblique loading, stress concentrated primarily in the cortical bone, whereas D4 cancellous bone showed increased susceptibility to microdamage. Prosthetic materials demonstrated no significant differences in stress behavior. These findings suggest that connection design and bone density strongly influence biomechanical performance and should guide individualized implant selection.
- Open Access
- 13 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11674
Stability of the Implant–Alveolar Bone Complex According to the Peri-Implant Bone Loss and Bone Quality: A Finite Element Analysis Study
Peri-implant bone loss and bone quality significantly affect the biomechanical stability and long-term success of dental implants. This study used finite element analysis to evaluate the stress distribution and deformation behavior of implants and alveolar bone according to bone loss (0–5 mm) and bone quality (normal and low). A finite element model was implemented based on a three-dimensional mandibular model. The mechanical properties of each component were assigned, and finite element analysis was performed using a static occlusal load. The results showed that progressive bone loss increased von Mises stresses in the implant fixture and surrounding bone, and low-quality bone showed a significant vulnerability to stress concentration. The 2 mm bone loss model showed the maximum stress in cortical bone, and from 3 mm onwards, the stress decreased due to extensive loss of cortical bone. This may be because extensive bone loss causes the implant to lose interface with cortical bone and contact only with cancellous bone. This study confirmed that bone loss and the vulnerability of bone quality may potentially affect implant failure. Continued research is needed to suggest customized implants based on the structural vulnerability of alveolar bone.
- 13 December 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (24) , 11674
Open AccessStability of the Implant–Alveolar Bone Complex According to the Peri-Implant Bone Loss and Bone Quality: A Finite Element Analysis Study
Peri-implant bone loss and bone quality significantly affect the biomechanical stability and long-term success of dental implants. This study used finite element analysis to evaluate the stress distribution and deformation behavior of implants and alveolar bone according to bone loss (0–5 mm) and bone quality (normal and low). A finite element model was implemented based on a three-dimensional mandibular model. The mechanical properties of each component were assigned, and finite element analysis was performed using a static occlusal load. The results showed that progressive bone loss increased von Mises stresses in the implant fixture and surrounding bone, and low-quality bone showed a significant vulnerability to stress concentration. The 2 mm bone loss model showed the maximum stress in cortical bone, and from 3 mm onwards, the stress decreased due to extensive loss of cortical bone. This may be because extensive bone loss causes the implant to lose interface with cortical bone and contact only with cancellous bone. This study confirmed that bone loss and the vulnerability of bone quality may potentially affect implant failure. Continued research is needed to suggest customized implants based on the structural vulnerability of alveolar bone.
- Open Access
- 10 December 2024
- Published by MDPI AG in Preprints.org
Stability of the Implant-Alveolar Bone Complex According to the Peri-Implant Bone Loss and Bone Quality: A Finite Element Analysis Study
Peri-implant bone loss and bone quality significantly affect the biomechanical stability and long-term success of dental implants. This study used finite element analysis to evaluate the stress distribution and deformation behavior of implants and alveolar bone according to bone loss (0–5 mm) and bone quality (normal and low). A finite element model was implemented based on a three-dimensional mandibular model. The mechanical properties of each component were assigned, and finite element analysis was performed using a static occlusal load. Results showed that progressive bone loss increased von Mises stresses in the implant fixture and surrounding bone, and low quality bone showed a significant vulnerability to stress concentration. The 2 mm bone loss model showed the maximum stress in cortical bone, and from 3 mm onwards, the stress decreased due to extensive loss of cortical bone. This may be because extensive bone loss causes the implant to lose interface with cortical bone and contact only with cancellous bone. This study confirmed that bone loss and the vulnerability of bone quality may potentially affect implant failure. Continued research is needed to suggest customized implants based on the structural vulnerability of alveolar bone.
- 10 December 2024
- Published by MDPI AG in Preprints.org
Open AccessStability of the Implant-Alveolar Bone Complex According to the Peri-Implant Bone Loss and Bone Quality: A Finite Element Analysis Study
Peri-implant bone loss and bone quality significantly affect the biomechanical stability and long-term success of dental implants. This study used finite element analysis to evaluate the stress distribution and deformation behavior of implants and alveolar bone according to bone loss (0–5 mm) and bone quality (normal and low). A finite element model was implemented based on a three-dimensional mandibular model. The mechanical properties of each component were assigned, and finite element analysis was performed using a static occlusal load. Results showed that progressive bone loss increased von Mises stresses in the implant fixture and surrounding bone, and low quality bone showed a significant vulnerability to stress concentration. The 2 mm bone loss model showed the maximum stress in cortical bone, and from 3 mm onwards, the stress decreased due to extensive loss of cortical bone. This may be because extensive bone loss causes the implant to lose interface with cortical bone and contact only with cancellous bone. This study confirmed that bone loss and the vulnerability of bone quality may potentially affect implant failure. Continued research is needed to suggest customized implants based on the structural vulnerability of alveolar bone.