JRJinlu Ruan

Jinlu Ruan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jinlu Ruan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Simulation and experiment study of performances of the hybrid photomultiplier tube based on a SiC detector

    by Jinlu Ruan, Xue Du, Liang Chen, Yapeng Zhang, Yicheng Yi, Fangbao Wang, Naizhe Zhao, Wenyu Shu, Xiaoping Ouyang

    Because of its advantages such as large maximum linear current, fast time response and radiation resistance, the hybrid photomultiplier tube based on a SiC detector (SiC-HPMT) is expected to become an important photon detector for the scintillation detectors used in measuring intense pulsed radiation fields. The performance of the SiC-HPMT is dependent on the electron transport process and properties of the SiC detector. The properties of the SiC detector have been studied in detail. However, how the electron transport process affects the performance of the SiC-HPMT is still unclear. Therefore, the influence of the electron transport process on the performance of the SiC-HPMT was simulated by the CST software. According to the simulation results, the leading edge, the trailing edge and the full width at half maximum of the electron transport time are only 0.24 ns, less than 1.5 ns and less than 1 ns, respectively, which is significantly smaller than the temporal response of the SiC detector. Therefore, the temporal response of the SiC-HPMT is mainly determined by the SiC detector. Moreover, the maximum linear current (MLC) of the SiC-HPMT can be significantly improved by adjusting the distribution of the electric field. The variation trend obtained from experiments is consistent with simulations. The experimental result indicated that the MLC is larger than 1 A. This study provides important theoretical guidance for optimizing the performance of the SiC-HPMT, which can make the SiC-HPMT more advantageous in applications for measuring pulsed radiation fields.

  • Study on Properties of a Hybrid Photomultiplier Tube Based on a SiC Schottky Diode Combined With an MCP

    by Jinlu Ruan, Liang Chen, Pengxiao Xu, Yapeng Zhang, Xue Du, Fangbao Wang, Shiyi He, Xun Zhang, Yang Li, Peng Jin, et al.

    Scintillation detector is one of the key detectors for measurements of pulsed radiation fields due to its high sensitivity, and fast time response. In a scintillation detector, the photomultiplier tube need have a high gain, a fast temporal response, and a large maximum linear current (MLC). The hybrid photomultiplier tube based on a SiC detector (SiC-HPMT) with a larger MLC is expected to become one kind of the important photon detectors for the measurements of pulsed radiation fields with a high intensity. However, the inherent problem is that the currently used hybrid photomultiplier is severely restricted by a low gain. On the basis of maintaining the original excellent properties, such as fast temporal response and large MLC, a novel hybrid photomultiplier tube (MCP-SiC-HPMT) which is composed of SiC-HPMT and a microchannel plate (MCP) is developed to offer an effective way to improve the gain. According to the experimental results, the influence laws of the accelerating and focusing voltage and the bias voltage of the SiC detector on its properties such as the gain, dark current, temporal response, and MLC were obtained. The gain and the MLC of the MCP-SiC-HPMT can reach over 10 5 and 500 mA, respectively. Moreover, the result demonstrated that the temporal response of the MCP-SiC-HPMT has a leading edge of about 2 ns and a FWHM of about 4 ns, which is almost same as that of the SiC-HPMT. The addition of the MCP does not only improve their gain, but also have no significant impact on its excellent performance. The detector based on an EJ228 scintillator and the MCP-SiC-HPMT successfully measured the multiple peaks characteristic of a pulsed X-ray source, which indicated that the MCP-SiC-HPMT can well meet the requirements of the temporal characteristics measurement of a pulsed device. The detector combining a stilbene scintillator with the developed MCP-SiC-HPMT can well discriminate the neutron and gamma rays produced by a D-T neutron source. The successful development of the MCP-SiC-HPMT can further expand the applications in pulsed radiation field measurements and show the great potential in the field of particle detections for hybrid photomultiplier tubes (HPMTs).

  • Open Access

    Measurement of relative neutron energy response curve of plastic scintillator detector based on the back-n-white neutron source at CSNS

    by Yapeng Zhang, Jinlu Ruan, Liang Chen, Jianfu Zhang, Shiyi He, Kuo Zhao, Leidang Zhou, Silong Zhang, Naizhe Zhao, Yang Li, et al.

    The plastic scintillator detector is widely used to measure pulsed radiation fields, and a high-quality neutron energy response curve is crucial for accurately determining neutron yields. Traditionally, the neutron energy response curve can be obtained by the simulation of the performance of neutron detectors via the knowledge of the light yield of secondary particles or direct measuring energy response. Both methods record signals by a data acquisition system in the counting mode. This work establishes a new model to directly measure the energy response to neutrons of a plastic scintillator detector in current mode with white source spectra. The plastic scintillator detector can be triggered externally. There is no signal loss and dead time, and it is possible to calibrate the neutron detector with a high-intensity neutron source. Efficiencies can be determined at all energies simultaneously, and a rapid calibration of the plastic scintillator detector is available. To validate the experimental results, the theoretical values are obtained by Geant4 simulation, and the results reproduce the shapes of the experimental curves reasonably well. The neutron energy response curves of the detector show that when the thickness of the scintillator is reduced from 3 to 1 mm, the reduction ratio of gamma signal intensity is greater than that of neutron signal intensity, which leads to an increase in the neutron–gamma sensitivity ratio. Meanwhile, the thin scintillator thickness can obtain a somewhat flatter neutron energy response curve compared with other thicknesses.