Hun Yi Koh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hun Yi Koh has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Hamid Rahmatullah Bin Abd Razak
Musculoskeletal Sciences, Duke-National University of Singapore (NUS) Medical School, Singapore, SGP
1 shared publication- Jiawen Fong
Department of Orthopaedic Surgery, Sengkang General Hospital, Singapore, Singapore
1 shared publication Kong Hwee Lee
Orthopaedic Surgery, Singapore General Hospital, Singapore, SGP
1 shared publicationKosala Mbbs Tennakoon
Sengkang General Hospital, Singapore
1 shared publicationMerng Koon Mbbs Wong
Sengkang General Hospital, Singapore
1 shared publicationWalter-Soon-Yaw MBChB Wong
Sengkang General Hospital, Singapore
1 shared publication
Latest Publications
- Open Access
- 1 April 2026
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 12 (4) , 64
Hirayama disease in a young Indonesian male: a case report
Background: Hirayama disease (HD) is a rare, self-limiting lower motor neuron disorder predominantly affecting young males in Asia. It is caused by dynamic compression of the lower cervical spinal cord during neck flexion, resulting in ischemic injury to the anterior horn cells. Case Description: A 15-year-old Indonesian male presented with a 6-month history of progressive right upper limb weakness and muscle wasting without sensory deficits or spasticity. Electromyography (EMG) showed motor neurogenic changes with ongoing denervation and fasciculations in the right upper limb, with possible anterior horn cell (AHC) involvement. Cervical magnetic resonance imaging (MRI) in the neutral position appeared normal initially. However, a repeat dynamic MRI cervical spine demonstrated anterior displacement of the posterior dural sac and dilatation of the posterior epidural venous plexus from C3–6 with neck flexion, confirming the diagnosis of HD. The patient was managed conservatively with a hard cervical collar and physiotherapy. At 8 months’ follow-up, symptoms continued to be stable with no further progression. Conclusions: Although rare, HD should be considered in adolescents presenting with unilateral distal upper limb weakness. It can often be underdiagnosed due to normal findings on neutral MRI cervical spine. As such, flexion imaging is essential for detecting the hallmark signs like anterior dural displacement and posterior epidural venous engorgement. With early recognition, conservative management with a cervical collar can halt disease progression and preserve neurological function.
- 1 April 2026
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 12 (4) , 64
Open AccessHirayama disease in a young Indonesian male: a case report
Background: Hirayama disease (HD) is a rare, self-limiting lower motor neuron disorder predominantly affecting young males in Asia. It is caused by dynamic compression of the lower cervical spinal cord during neck flexion, resulting in ischemic injury to the anterior horn cells. Case Description: A 15-year-old Indonesian male presented with a 6-month history of progressive right upper limb weakness and muscle wasting without sensory deficits or spasticity. Electromyography (EMG) showed motor neurogenic changes with ongoing denervation and fasciculations in the right upper limb, with possible anterior horn cell (AHC) involvement. Cervical magnetic resonance imaging (MRI) in the neutral position appeared normal initially. However, a repeat dynamic MRI cervical spine demonstrated anterior displacement of the posterior dural sac and dilatation of the posterior epidural venous plexus from C3–6 with neck flexion, confirming the diagnosis of HD. The patient was managed conservatively with a hard cervical collar and physiotherapy. At 8 months’ follow-up, symptoms continued to be stable with no further progression. Conclusions: Although rare, HD should be considered in adolescents presenting with unilateral distal upper limb weakness. It can often be underdiagnosed due to normal findings on neutral MRI cervical spine. As such, flexion imaging is essential for detecting the hallmark signs like anterior dural displacement and posterior epidural venous engorgement. With early recognition, conservative management with a cervical collar can halt disease progression and preserve neurological function.
- Open Access
- 18 June 2025
- Published by Springer Nature in Cureus
- Vol. 17 (6) , e86272
The Novel Osteopore® Wedge in Medial Opening Wedge High Tibial Osteotomy: A Technical Note
Medial opening wedge high tibial osteotomy (MOWHTO) is a highly common procedure for correcting varus malalignment of the knee. The current gold standard for filling this osteotomy gap is autologous bone graft, which is associated with donor site morbidity. Allograft bone graft is also an alternative; however, it is associated with certain disadvantages, such as storage cost, limited supply, and the risk of infection transmission. Consequently, there has been a growing interest in and further developments of synthetic options for filling the osteotomy gap. We would like to introduce and describe the process of manufacturing and utilizing the novel Osteopore® 3D-printed, honeycomb-structured, polycaprolactone and β-tricalcium phosphate (PCL-TCP) synthetic bone wedge for filling the gap in MOWHTO. This study will also include illustrations of postoperative radiographs and CT scans to showcase bony remodeling over a period of up to 12 months. In the era of additive manufacturing and the pursuit of more biocompatible materials, the use of a patient-specific 3D-printed, honeycomb-structured, PCL-TCP bone spacer wedge in MOWHTO is promising and may serve as a viable alternative to autograft and allograft bone grafts. It offers the potential to maintain biomechanical stability and facilitate the healing of the osteotomy gap without the associated drawbacks of bone graft.
- 18 June 2025
- Published by Springer Nature in Cureus
- Vol. 17 (6) , e86272
Open AccessThe Novel Osteopore® Wedge in Medial Opening Wedge High Tibial Osteotomy: A Technical Note
Medial opening wedge high tibial osteotomy (MOWHTO) is a highly common procedure for correcting varus malalignment of the knee. The current gold standard for filling this osteotomy gap is autologous bone graft, which is associated with donor site morbidity. Allograft bone graft is also an alternative; however, it is associated with certain disadvantages, such as storage cost, limited supply, and the risk of infection transmission. Consequently, there has been a growing interest in and further developments of synthetic options for filling the osteotomy gap. We would like to introduce and describe the process of manufacturing and utilizing the novel Osteopore® 3D-printed, honeycomb-structured, polycaprolactone and β-tricalcium phosphate (PCL-TCP) synthetic bone wedge for filling the gap in MOWHTO. This study will also include illustrations of postoperative radiographs and CT scans to showcase bony remodeling over a period of up to 12 months. In the era of additive manufacturing and the pursuit of more biocompatible materials, the use of a patient-specific 3D-printed, honeycomb-structured, PCL-TCP bone spacer wedge in MOWHTO is promising and may serve as a viable alternative to autograft and allograft bone grafts. It offers the potential to maintain biomechanical stability and facilitate the healing of the osteotomy gap without the associated drawbacks of bone graft.
- 9 December 2024
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 40 (2)
Use of Tourniquet to Achieve Closed Reduction for a Distal Femoral Fracture With an Intramedullary Device
- 9 December 2024
- Published by Wolters Kluwer Health in Techniques in Orthopaedics
- Vol. 40 (2)
Use of Tourniquet to Achieve Closed Reduction for a Distal Femoral Fracture With an Intramedullary Device