Antoni Femenias
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Antoni Femenias has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Boris Mizaikoff
Institute of Analytical and Bioanalytical Chemistry Ulm University Ulm Germany
2 shared publications - Polina Fomina
Institute of Analytical and Bioanalytical Chemistry Ulm University Ulm Germany
2 shared publications - Rudolf Krska
Department of Agricultural Sciences, Institute of Bioanalytics and Agro-Metabolomics, BOKU University, Tulln, Austria
2 shared publications - Stephan Freitag
BOKU University
2 shared publications - Achim Kohler
Faculty of Science and Technology, Norwegian University of Life Sciences, Ås, Norway
1 shared publication - Achim Kohler
Faculty of Science and Technology
1 shared publication
Latest Publications
- Open Access
- 17 December 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Attenuated Total Reflection Mid-Infrared Spectroscopy to Screen Austrian and French Wheat from Multiple Years for Deoxynivalenol
The high-throughput capabilities of attenuated total reflection mid-infrared spectroscopy (ATR-MIRS) make it a promising analytical technique for rapid and green mycotoxin screening. In ATR-MIRS, changes in samples induced by mycotoxigenic fungi are correlated with mycotoxin concentrations obtained through reference analysis, using multivariate statistical methods. Due to its indirect nature, limited research has explored the applicability of this technique for complex sample sets. In this study, we demonstrate that ATR-MIRS can effectively screen for deoxynivalenol (DON) contamination in wheat samples collected across two countries over multiple years. A total of 320 naturally contaminated samples from Austria and France were utilized to develop screening models. Partial least squares discriminant analysis (PLS-DA), combined with various spectral preprocessing strategies and dataset balancing, was explored to classify samples as compliant or non-compliant with the European Commission (EC) limit of 1000 µg/kg DON in unprocessed wheat. Model performance during repeated nested cross-validation exhibited a true positive rate ranging from 0.32 to 1. This variability was primarily influenced by sample splitting, as well as by dataset balancing and spectral preprocessing approaches. These findings underscore the critical importance of sample selection when developing chemometric models for mycotoxin screening. Analysis of variable importance in projection (VIP) scores revealed that PLS-DA predominantly selected wavenumbers associated with dissolved carbohydrates in the MIRS spectra to discriminate between compliant and non-compliant samples. Overall, our results demonstrate the feasibility of using ATR-MIRS to assess DON contamination in complex, multiyear wheat sample sets as exemplified for samples obtained from Austria and France while adhering to regulatory limits. Additionally, this study highlights the potential of ATR-MIRS for investigating the effects of mycotoxigenic fungi on wheat composition during the development of DON screening models.
- 17 December 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessAttenuated Total Reflection Mid-Infrared Spectroscopy to Screen Austrian and French Wheat from Multiple Years for Deoxynivalenol
The high-throughput capabilities of attenuated total reflection mid-infrared spectroscopy (ATR-MIRS) make it a promising analytical technique for rapid and green mycotoxin screening. In ATR-MIRS, changes in samples induced by mycotoxigenic fungi are correlated with mycotoxin concentrations obtained through reference analysis, using multivariate statistical methods. Due to its indirect nature, limited research has explored the applicability of this technique for complex sample sets. In this study, we demonstrate that ATR-MIRS can effectively screen for deoxynivalenol (DON) contamination in wheat samples collected across two countries over multiple years. A total of 320 naturally contaminated samples from Austria and France were utilized to develop screening models. Partial least squares discriminant analysis (PLS-DA), combined with various spectral preprocessing strategies and dataset balancing, was explored to classify samples as compliant or non-compliant with the European Commission (EC) limit of 1000 µg/kg DON in unprocessed wheat. Model performance during repeated nested cross-validation exhibited a true positive rate ranging from 0.32 to 1. This variability was primarily influenced by sample splitting, as well as by dataset balancing and spectral preprocessing approaches. These findings underscore the critical importance of sample selection when developing chemometric models for mycotoxin screening. Analysis of variable importance in projection (VIP) scores revealed that PLS-DA predominantly selected wavenumbers associated with dissolved carbohydrates in the MIRS spectra to discriminate between compliant and non-compliant samples. Overall, our results demonstrate the feasibility of using ATR-MIRS to assess DON contamination in complex, multiyear wheat sample sets as exemplified for samples obtained from Austria and France while adhering to regulatory limits. Additionally, this study highlights the potential of ATR-MIRS for investigating the effects of mycotoxigenic fungi on wheat composition during the development of DON screening models.
- Open Access
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Portable tunable interband cascade laser spectrometer using thin-film waveguides for food contaminant analysis
Interband cascade lasers (ICL) are high output power mid-infrared light sources with low power consumption, serving as a viable alternative to more commonly applied quantum cascade lasers. The integration of ICLs with thin-film waveguides facilitates miniaturized sensing platforms based on the principles of evanescent field absorption toward tailorable high-fidelity portable mid-infrared (MIR) sensing solutions for on-site chemical analysis. The analytical performance of a MIR sensing system is presented combining a tunable interband cascade laser emitting at a wavelength range of 5.88–6.09 µm (1702–1641 cm−1) with a 6 µm GaAs/AlGaAs thin-film waveguide as the active transducer for customized evanescent field absorption analysis of food contaminants. A comparison of the analytical performance of the developed tICL-based system vs conventional Fourier-transform infrared spectroscopy is presented for the exemplary analysis of the Fusarium mycotoxin deoxynivalenol, a persistent food contaminant resulting from fungal infection. The thin-film waveguide enhances the sensitivity compared to conventional attenuated total reflection systems, revealing improved detection limits. The compact design of the system, along with the favorable analytical figures-of-merit and automated data processing, confirm the potential of the developed tICL-based spectrometer for on-site detection of food contaminants at various stages along the food supply chain.
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Open AccessPortable tunable interband cascade laser spectrometer using thin-film waveguides for food contaminant analysis
Interband cascade lasers (ICL) are high output power mid-infrared light sources with low power consumption, serving as a viable alternative to more commonly applied quantum cascade lasers. The integration of ICLs with thin-film waveguides facilitates miniaturized sensing platforms based on the principles of evanescent field absorption toward tailorable high-fidelity portable mid-infrared (MIR) sensing solutions for on-site chemical analysis. The analytical performance of a MIR sensing system is presented combining a tunable interband cascade laser emitting at a wavelength range of 5.88–6.09 µm (1702–1641 cm−1) with a 6 µm GaAs/AlGaAs thin-film waveguide as the active transducer for customized evanescent field absorption analysis of food contaminants. A comparison of the analytical performance of the developed tICL-based system vs conventional Fourier-transform infrared spectroscopy is presented for the exemplary analysis of the Fusarium mycotoxin deoxynivalenol, a persistent food contaminant resulting from fungal infection. The thin-film waveguide enhances the sensitivity compared to conventional attenuated total reflection systems, revealing improved detection limits. The compact design of the system, along with the favorable analytical figures-of-merit and automated data processing, confirm the potential of the developed tICL-based spectrometer for on-site detection of food contaminants at various stages along the food supply chain.