Jiali Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiali Li has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Zhenhua Tian
Department of Mechanical Engineering Virginia Polytechnic Institute and State University Blacksburg Virginia USA
6 shared publications - Bowen Cai
Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, 24060, USA
5 shared publications - Luyu Bo
Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, 24060, USA
5 shared publications - Teng Li
Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, 24060, USA
5 shared publications - Chongpeng Qiu
Department of Mechanical Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA, 24060, USA
4 shared publications - Yingshan Du
Department of Biomedical Engineering Virginia Polytechnic Institute and State University Blacksburg Virginia USA
4 shared publications
Latest Publications
- Open Access
Acoustic Tweezers‐Assisted Biomaterial Molding in Petri Dishes (TAMP) for Engineering Glioma Tissues With Controlled Cellular and Extracellular Matrix Architectures
Tissue engineering has shown great potential for manufacturing tissue replacements and developing physiologically relevant tissue models. However, conventional tissue engineering strategies often face challenges in fabricating tissues simultaneously incorporating controlled cellular and extracellular matrix (ECM) architectures. Here, we introduce Acoustic Tweezers‐Assisted Biomaterial Molding in Petri Dishes (TAMP), enabling tissue fabrication with controlled cellular and ECM architectures in Petri dishes, specifically, producing constructs with customized ECM geometries and various internal cellular architectures, including parallel elongated cell bundles, arrays of interconnected cell spheroids, and lattice‐like cellular networks. TAMP leverages a portable acoustic array that delivers standing waves into a Petri dish or a polydimethylsiloxane (PDMS) mold, thereby enabling a unique “dual‐control” mechanism. The acoustic field arranges internal cells into parallel line‐like and lattice‐like patterns, while the PDMS mold defines the overall ECM geometry. Our approach was demonstrated by arranging micro‐objects into various patterns within different‐shaped molds and fabricating glioma tissues with various unique internal cellular architectures, including parallel elongated glioma tissue bundles, lattice‐like glioma tissue networks, and chains of interconnected glioma spheroids. We anticipate the TAMP technique will lead to portable, easy‐to‐operate tools for engineering tissues with controlled cellular and ECM architectures for biomedical research, disease modeling, and drug testing.
Open AccessAcoustic Tweezers‐Assisted Biomaterial Molding in Petri Dishes (TAMP) for Engineering Glioma Tissues With Controlled Cellular and Extracellular Matrix Architectures
Tissue engineering has shown great potential for manufacturing tissue replacements and developing physiologically relevant tissue models. However, conventional tissue engineering strategies often face challenges in fabricating tissues simultaneously incorporating controlled cellular and extracellular matrix (ECM) architectures. Here, we introduce Acoustic Tweezers‐Assisted Biomaterial Molding in Petri Dishes (TAMP), enabling tissue fabrication with controlled cellular and ECM architectures in Petri dishes, specifically, producing constructs with customized ECM geometries and various internal cellular architectures, including parallel elongated cell bundles, arrays of interconnected cell spheroids, and lattice‐like cellular networks. TAMP leverages a portable acoustic array that delivers standing waves into a Petri dish or a polydimethylsiloxane (PDMS) mold, thereby enabling a unique “dual‐control” mechanism. The acoustic field arranges internal cells into parallel line‐like and lattice‐like patterns, while the PDMS mold defines the overall ECM geometry. Our approach was demonstrated by arranging micro‐objects into various patterns within different‐shaped molds and fabricating glioma tissues with various unique internal cellular architectures, including parallel elongated glioma tissue bundles, lattice‐like glioma tissue networks, and chains of interconnected glioma spheroids. We anticipate the TAMP technique will lead to portable, easy‐to‐operate tools for engineering tissues with controlled cellular and ECM architectures for biomedical research, disease modeling, and drug testing.
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Research
- Vol. 9
Laser Vibrometry and Dispersion Analysis-Enabled Mechanical Property Characterization for Additively Manufactured Thermoset Composites
Large-format additive manufacturing of thermoset composites enables rapid fabrication of large structures, but nondestructive characterization of their print-path-dependent mechanical behavior remains difficult. Existing qualification routes rely mainly on destructive coupon testing or defect-oriented nondestructive evaluation and therefore provide limited capability for targeted mapping of direction-dependent mechanical variability. This study presents a piezoelectric transducer–laser Doppler vibrometry framework for direction-conditioned dispersion inversion of full-field guided wave measurements in additively manufactured thermoset composites. The method decomposes the frequency–wavenumber spectrum by propagation angle and independently fits the extracted dispersion data in each propagation direction to obtain scan-region-specific effective shear-wave velocity, an effective Poisson’s-ratio parameter, and effective-modulus responses as functions of propagation direction. Benchmark testing on an isotropic aluminum plate validates that the workflow recovers isotropic guided wave behavior without introducing artificial angular bias. Applied to a chopped-carbon-fiber thermoset composite, the framework reveals print-path-dependent anisotropic wave propagation through elliptical wavefields and frequency–wavenumber spectra. The resulting effective stiffness estimates reproduce the direction-dependent stiffness variation and approximate magnitude observed in conventional tensile measurements, supporting the mechanical relevance of the guided wave-derived response. By converting full-field guided wave measurements into scan-region-specific, direction-resolved effective-stiffness estimates, this work provides a practical nondestructive route to support quality control, process validation, and structural evaluation of aerospace composite tooling manufactured by large-format thermoset additive manufacturing.
- 1 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Research
- Vol. 9
Laser Vibrometry and Dispersion Analysis-Enabled Mechanical Property Characterization for Additively Manufactured Thermoset Composites
Large-format additive manufacturing of thermoset composites enables rapid fabrication of large structures, but nondestructive characterization of their print-path-dependent mechanical behavior remains difficult. Existing qualification routes rely mainly on destructive coupon testing or defect-oriented nondestructive evaluation and therefore provide limited capability for targeted mapping of direction-dependent mechanical variability. This study presents a piezoelectric transducer–laser Doppler vibrometry framework for direction-conditioned dispersion inversion of full-field guided wave measurements in additively manufactured thermoset composites. The method decomposes the frequency–wavenumber spectrum by propagation angle and independently fits the extracted dispersion data in each propagation direction to obtain scan-region-specific effective shear-wave velocity, an effective Poisson’s-ratio parameter, and effective-modulus responses as functions of propagation direction. Benchmark testing on an isotropic aluminum plate validates that the workflow recovers isotropic guided wave behavior without introducing artificial angular bias. Applied to a chopped-carbon-fiber thermoset composite, the framework reveals print-path-dependent anisotropic wave propagation through elliptical wavefields and frequency–wavenumber spectra. The resulting effective stiffness estimates reproduce the direction-dependent stiffness variation and approximate magnitude observed in conventional tensile measurements, supporting the mechanical relevance of the guided wave-derived response. By converting full-field guided wave measurements into scan-region-specific, direction-resolved effective-stiffness estimates, this work provides a practical nondestructive route to support quality control, process validation, and structural evaluation of aerospace composite tooling manufactured by large-format thermoset additive manufacturing.
- Open Access
- 11 August 2025
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 6 (18) , 6394-6405
In-Petri-dish traveling and standing acoustic wave-assisted fabrication of anisotropic collagen hydrogels
Traveling and standing acoustic wave-based approaches enable the rapid in-Petri-dish fabrication of anisotropic collagen hydrogels.
- 11 August 2025
- Published by Royal Society of Chemistry (RSC) in Materials Advances
- Vol. 6 (18) , 6394-6405
Open AccessIn-Petri-dish traveling and standing acoustic wave-assisted fabrication of anisotropic collagen hydrogels
Traveling and standing acoustic wave-based approaches enable the rapid in-Petri-dish fabrication of anisotropic collagen hydrogels.
- 6 August 2025
- Published by Elsevier in Ultrasonics
- Vol. 157, 107787
Noncontact pulsed laser-scanning laser Doppler vibrometer (PL-SLDV) phased array imaging for damage detection in composites
- 6 August 2025
- Published by Elsevier in Ultrasonics
- Vol. 157, 107787
Noncontact pulsed laser-scanning laser Doppler vibrometer (PL-SLDV) phased array imaging for damage detection in composites
- Open Access
- 1 July 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (15) , 3766-3778
In-Petri-dish acoustic vortex tweezers
This study presents an acoustic vortex tweezers platform that enables contactless, precise, multi-degree-of-freedom, and multifunctional manipulation of micro- to millimeter-sized objects within a Petri dish.
- 1 July 2025
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (15) , 3766-3778
Open AccessIn-Petri-dish acoustic vortex tweezers
This study presents an acoustic vortex tweezers platform that enables contactless, precise, multi-degree-of-freedom, and multifunctional manipulation of micro- to millimeter-sized objects within a Petri dish.
- Open Access
- 10 December 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 13 (3) , 2047-2055
Enhancing performance of lithium metal batteries through acoustic field application
The graphic illustrates how an external acoustic field stabilizes the SEI layer by enhancing lithium-ion mass transfer at slip lines and kinks, reducing pit formation and promoting a more uniform SEI, ultimately improving battery performance.
- 10 December 2024
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry A
- Vol. 13 (3) , 2047-2055
Open AccessEnhancing performance of lithium metal batteries through acoustic field application
The graphic illustrates how an external acoustic field stabilizes the SEI layer by enhancing lithium-ion mass transfer at slip lines and kinks, reducing pit formation and promoting a more uniform SEI, ultimately improving battery performance.