Nagisa Matsui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nagisa Matsui has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Akimasa Tsujimoto
Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University, Nagoya 464-8651, Japan
3 shared publications - Mayumi Maesako
Department of Operative Dentistry, School of Dentistry, Aichi Gakuin University, Nagoya 464-8651, Japan
3 shared publications - Masao Irie
Department of Biomaterials, Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, 2-5-1 Shikata-cho, Kita-ku, Okayama 700-8525, Japan
2 shared publications - Ahmad Alkhazaleh
Department of Restorative Dentistry, Oregon Health Science University School of Dentistry, Portland, OR 97201, USA
1 shared publication - Ahmad Mahrous
A.T. Still University Arizona School of Dentistry, Mesa, AZ 85206, USA
1 shared publication - Amira Elgreatly
A.T. Still University Arizona School of Dentistry, Mesa, AZ 85206, USA
1 shared publication
Latest Publications
- Open Access
- 16 July 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 815
Laboratory and Clinical Efficacy of 6% Hydrogen Peroxide At-Home Whitening Systems with Custom Trays
Demand for fast and convenient dental whitening has increased in recent years. This paper compares the efficacy of three home whitening systems (TiON Take Home with (W), Opalescence Go (G), and Angelus Home 16% (A)) and presents a clinical case. W and G contain 6% hydrogen peroxide, while A contains 16% carbamide peroxide, approximately equal active peroxide contents. The whitening agents were applied to brown chicken eggshells for 90 (W90, G90, A90) or 60 (W60) minute periods ten (W90, W60, G90) or fourteen (A90) times. The color was measured before treatment, and after 3, 5, 7, 10, 12, and 14 applications. ∆E*ab was calculated at each point. ∆E*ab at completion were 4.97 (A90), 7.25 (G90), 9.84 (W60), and 14.96 (W90). A clinical study of the efficacy of W60 found a ∆E*ab of 4.18. The whitening efficacy of a system is not determined entirely by the content of active peroxide.
- 16 July 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (7) , 815
Open AccessLaboratory and Clinical Efficacy of 6% Hydrogen Peroxide At-Home Whitening Systems with Custom Trays
Demand for fast and convenient dental whitening has increased in recent years. This paper compares the efficacy of three home whitening systems (TiON Take Home with (W), Opalescence Go (G), and Angelus Home 16% (A)) and presents a clinical case. W and G contain 6% hydrogen peroxide, while A contains 16% carbamide peroxide, approximately equal active peroxide contents. The whitening agents were applied to brown chicken eggshells for 90 (W90, G90, A90) or 60 (W60) minute periods ten (W90, W60, G90) or fourteen (A90) times. The color was measured before treatment, and after 3, 5, 7, 10, 12, and 14 applications. ∆E*ab was calculated at each point. ∆E*ab at completion were 4.97 (A90), 7.25 (G90), 9.84 (W60), and 14.96 (W90). A clinical study of the efficacy of W60 found a ∆E*ab of 4.18. The whitening efficacy of a system is not determined entirely by the content of active peroxide.
- Open Access
- 28 April 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (5) , 155
Correlation Between Polymerization Shrinkage and Filler Content for Universal Shade Flowable Resin-Based Composites
The purpose of this study was to measure the filler content by weight and volume of universal shade flowable resin-based composites and analyze the correlation between polymerization shrinkage and filler content. The filler content by weight of six universal shade flowalble resin-based composites (Bulk Base Hard II Medium Flow, A-Uno Flow Basic, Clearfil Majesty ES Flow Low, Gracefill Low Flow, Omnichroma Flow, Omnichroma Flow Bulk) was measured in accordance with ISO 17304. The filler content by volume of each flowable resin-based composite was determined by measuring the density of the filler using a dry density meter, and the filler content by volume of the composite was calculated from the densities obtained. The correlations between filler content by weight or volume, polymerization shrinkage and filler content by weight ratio, and polymerization shrinkage and filler content by volume were analyzed. The filler content of the universal flowable resin-based composites ranged from 59.40 to 69.81% (by weight) and from 40.61 to 54.84% (by volume), and the correlations between the values for filler content of the composites by weight and volume were weakly negative and not statistically significant. The correlations between polymerization shrinkage (3.15–4.48%) and filler content by weight or volume were also not statistically significant.
- 28 April 2025
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 16 (5) , 155
Open AccessCorrelation Between Polymerization Shrinkage and Filler Content for Universal Shade Flowable Resin-Based Composites
The purpose of this study was to measure the filler content by weight and volume of universal shade flowable resin-based composites and analyze the correlation between polymerization shrinkage and filler content. The filler content by weight of six universal shade flowalble resin-based composites (Bulk Base Hard II Medium Flow, A-Uno Flow Basic, Clearfil Majesty ES Flow Low, Gracefill Low Flow, Omnichroma Flow, Omnichroma Flow Bulk) was measured in accordance with ISO 17304. The filler content by volume of each flowable resin-based composite was determined by measuring the density of the filler using a dry density meter, and the filler content by volume of the composite was calculated from the densities obtained. The correlations between filler content by weight or volume, polymerization shrinkage and filler content by weight ratio, and polymerization shrinkage and filler content by volume were analyzed. The filler content of the universal flowable resin-based composites ranged from 59.40 to 69.81% (by weight) and from 40.61 to 54.84% (by volume), and the correlations between the values for filler content of the composites by weight and volume were weakly negative and not statistically significant. The correlations between polymerization shrinkage (3.15–4.48%) and filler content by weight or volume were also not statistically significant.
- Open Access
- 11 December 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (12) , 753
Comparing Polymerization Shrinkage Measurement Methods for Universal Shade Flowable Resin-Based Composites
Universal shade flowable composites have been introduced to mimic tooth structure with reduced color mismatch and reduced chair time and cost. However, the polymerization shrinkage of resin material may lead to sensitivity and restoration failure. The purpose of this study was to compare the polymerization shrinkage of recently introduced universal shade flowable resin-based composites using both wet and dry density methods. Using two measurement methods, ISO 17304 (wet method) and a gas displacement pycnometry system (dry method), the density of the unpolymerized and the polymerized RBCs were measured, and the polymerization shrinkage was calculated from the density difference. Scanning electron microscopy was used to visualize filler particles. The polymerization shrinkage showed significant differences between many materials. In particular, Bulk Base HARD II Medium Flow showed significantly lower polymerization shrinkage than all the other materials. Shrinkages measured by different methods were significantly different in all cases. The wet method measured a smaller shrinkage than the dry method in most cases, but the shrinkage measured for Gracefil LoFlow was larger with the wet method. Shrinkage between universal shade flowable resin-based composites significantly varied based on both material and measurement method. The polymerization shrinkage of resin-based composites is an important factor in biomimetic clinical dentistry, and work must be conducted to measure it accurately and with more standardization.
- 11 December 2024
- Published by MDPI AG in Biomimetics
- Vol. 9 (12) , 753
Open AccessComparing Polymerization Shrinkage Measurement Methods for Universal Shade Flowable Resin-Based Composites
Universal shade flowable composites have been introduced to mimic tooth structure with reduced color mismatch and reduced chair time and cost. However, the polymerization shrinkage of resin material may lead to sensitivity and restoration failure. The purpose of this study was to compare the polymerization shrinkage of recently introduced universal shade flowable resin-based composites using both wet and dry density methods. Using two measurement methods, ISO 17304 (wet method) and a gas displacement pycnometry system (dry method), the density of the unpolymerized and the polymerized RBCs were measured, and the polymerization shrinkage was calculated from the density difference. Scanning electron microscopy was used to visualize filler particles. The polymerization shrinkage showed significant differences between many materials. In particular, Bulk Base HARD II Medium Flow showed significantly lower polymerization shrinkage than all the other materials. Shrinkages measured by different methods were significantly different in all cases. The wet method measured a smaller shrinkage than the dry method in most cases, but the shrinkage measured for Gracefil LoFlow was larger with the wet method. Shrinkage between universal shade flowable resin-based composites significantly varied based on both material and measurement method. The polymerization shrinkage of resin-based composites is an important factor in biomimetic clinical dentistry, and work must be conducted to measure it accurately and with more standardization.