Yiheng Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yiheng Hu has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Nan Zhao
School of Engineering Lancaster University Lancaster UK
5 shared publications - Lili Tao
Shanghai Polytechnic University, Shanghai, China
2 shared publications Nigel Schofield
School of Computing and Engineering University of Huddersfield Huddersfield UK
2 shared publicationsBoxi Chen
Sino‐German College of Intelligent Manufacturing Shenzhen Technology University Shenzhen China
1 shared publication- Da Xie
Shanghai Jiao Tong University
1 shared publication Fan Zhang
Shenzhen Power Bell Technology Co., Ltd Shenzhen China
1 shared publication
Latest Publications
- 29 October 2026
- Published by Wiley in Energy Storage
- Vol. 8 (8) , e70557
A Non‐Isothermal Dynamic Model for Vanadium Redox Flow Batteries With Gravitational Loss Analysis
Vanadium redox flow batteries (VRFB) are promising for long‐duration and large‐scale energy storage owing to their high safety, long cycle life, and independently scalable power and energy capacities. However, most existing dynamic models rely on isothermal or lumped‐parameter assumptions, which neglect gravitational losses, temperature‐dependent electrolyte properties, and heat transfer in pipelines. These simplifications limit their accuracy in representing practical VRFB operation, particularly in large‐scale energy storage systems. This study develops a non‐isothermal dynamic model for VRFB by coupling electrochemical, mass transfer, hydraulic, and thermal processes. Gravitational work is incorporated into the hydraulic loss formulation, while electrolyte density and viscosity are treated as temperature‐dependent time‐varying parameters. A three‐zone thermal model covering the storage tanks, transfer pipelines, and stack is further established to describe heat generation, dissipation, and intercomponent heat exchange. Experimental validation under different currents and flow rates showed good agreement between the simulated and measured voltage responses, with a maximum absolute error of 4.28%. The simulated temperatures also closely reproduced the measured thermal trends at the stack, tank, and pipelines. Furthermore, comparative analysis at different pipeline elevation heights showed that the pump‐loss current increased with height, confirming the contribution of gravitational head to parasitic losses. Sensitivity analysis further elucidated the effects of current and flow rate on voltage response and Coulombic efficiency. The proposed model provides a basis for state monitoring, thermal management, grid‐oriented control, and scale‐up analysis of VRFB energy storage systems.
- 29 October 2026
- Published by Wiley in Energy Storage
- Vol. 8 (8) , e70557
A Non‐Isothermal Dynamic Model for Vanadium Redox Flow Batteries With Gravitational Loss Analysis
Vanadium redox flow batteries (VRFB) are promising for long‐duration and large‐scale energy storage owing to their high safety, long cycle life, and independently scalable power and energy capacities. However, most existing dynamic models rely on isothermal or lumped‐parameter assumptions, which neglect gravitational losses, temperature‐dependent electrolyte properties, and heat transfer in pipelines. These simplifications limit their accuracy in representing practical VRFB operation, particularly in large‐scale energy storage systems. This study develops a non‐isothermal dynamic model for VRFB by coupling electrochemical, mass transfer, hydraulic, and thermal processes. Gravitational work is incorporated into the hydraulic loss formulation, while electrolyte density and viscosity are treated as temperature‐dependent time‐varying parameters. A three‐zone thermal model covering the storage tanks, transfer pipelines, and stack is further established to describe heat generation, dissipation, and intercomponent heat exchange. Experimental validation under different currents and flow rates showed good agreement between the simulated and measured voltage responses, with a maximum absolute error of 4.28%. The simulated temperatures also closely reproduced the measured thermal trends at the stack, tank, and pipelines. Furthermore, comparative analysis at different pipeline elevation heights showed that the pump‐loss current increased with height, confirming the contribution of gravitational head to parasitic losses. Sensitivity analysis further elucidated the effects of current and flow rate on voltage response and Coulombic efficiency. The proposed model provides a basis for state monitoring, thermal management, grid‐oriented control, and scale‐up analysis of VRFB energy storage systems.
- Open Access
- 8 May 2026
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 28 (5) , 1105-1125
Motor bearing fault early warning model for TCN integrating multi-attention mechanisms
Aiming at the problem of limited accuracy in motor bearing fault prediction under low-frequency, low-dimensional, and imbalanced data scenarios, this paper proposes a motor bearing fault early warning model based on a temporal convolutional network that integrates multi-attention mechanisms. The model leverages these mechanisms to enhance the network's ability to model long-term dependencies and focus on critical fault features from sparse data. To validate its performance, ablation and comparative experiments were conducted on a dataset of 10,000 samples collected from a self-built test bench. The experiment results demonstrate the superiority of the proposed model. Specifically, the Multi-Attention Temporal Convolutional Network achieved a coefficient of determination of 0.9629 and a Mean Absolute Error of 0.0244, significantly outperforming the standard Temporal Convolutional Network baseline which only achieved a Mean Absolute Error of 0.1349. These results indicate the excellent performance of the proposed model in this specific data prediction scenario, providing an effective solution to practical engineering problems where high-precision sensing equipment is unavailable.
- 8 May 2026
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 28 (5) , 1105-1125
Open AccessMotor bearing fault early warning model for TCN integrating multi-attention mechanisms
Aiming at the problem of limited accuracy in motor bearing fault prediction under low-frequency, low-dimensional, and imbalanced data scenarios, this paper proposes a motor bearing fault early warning model based on a temporal convolutional network that integrates multi-attention mechanisms. The model leverages these mechanisms to enhance the network's ability to model long-term dependencies and focus on critical fault features from sparse data. To validate its performance, ablation and comparative experiments were conducted on a dataset of 10,000 samples collected from a self-built test bench. The experiment results demonstrate the superiority of the proposed model. Specifically, the Multi-Attention Temporal Convolutional Network achieved a coefficient of determination of 0.9629 and a Mean Absolute Error of 0.0244, significantly outperforming the standard Temporal Convolutional Network baseline which only achieved a Mean Absolute Error of 0.1349. These results indicate the excellent performance of the proposed model in this specific data prediction scenario, providing an effective solution to practical engineering problems where high-precision sensing equipment is unavailable.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 20 (1) , e70354
Optimised Active Disturbance Rejection Control for Grid‐Connected Floating Offshore Wind Turbines Under Wave Disturbance
To mitigate the pronounced power fluctuations in floating offshore wind turbine (FOWT) systems induced by complex wind and wave conditions, this study proposes a novel grid‐connected control strategy that integrates Wave Disturbance Compensation (WDC) and active disturbance rejection control (ADRC). The objective of this strategy is to reduce the total harmonic distortion (THD) of grid‐connected voltage and current in the presence of non‐stationary disturbances. The WDC module suppresses low‐frequency wind‐wave‐induced fluctuations through a feedforward compensation mechanism, while the ADRC controller conducts real‐time disturbance estimation and rejection, thereby enhancing the robustness and operational stability of the system. To further improve control performance, an enhanced Whale Migration Algorithm, termed WMA–Lévy–Spiral, incorporating Lévy flight and a spiral contraction strategy, is developed for the global optimisation of ADRC parameters. A co‐simulation platform for a 5 MW FOWT was constructed using Simulink and OPENFAST, with the system's dynamic behaviour visualised via ParaView. Simulation results demonstrated that the proposed method reduced the THD of grid‐connected voltage and current to 2.46% and 0.91%, respectively. Moreover, hardware‐in‐the‐loop (HIL) experiments further verified the practical feasibility and effectiveness of the proposed control system.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 20 (1) , e70354
Open AccessOptimised Active Disturbance Rejection Control for Grid‐Connected Floating Offshore Wind Turbines Under Wave Disturbance
To mitigate the pronounced power fluctuations in floating offshore wind turbine (FOWT) systems induced by complex wind and wave conditions, this study proposes a novel grid‐connected control strategy that integrates Wave Disturbance Compensation (WDC) and active disturbance rejection control (ADRC). The objective of this strategy is to reduce the total harmonic distortion (THD) of grid‐connected voltage and current in the presence of non‐stationary disturbances. The WDC module suppresses low‐frequency wind‐wave‐induced fluctuations through a feedforward compensation mechanism, while the ADRC controller conducts real‐time disturbance estimation and rejection, thereby enhancing the robustness and operational stability of the system. To further improve control performance, an enhanced Whale Migration Algorithm, termed WMA–Lévy–Spiral, incorporating Lévy flight and a spiral contraction strategy, is developed for the global optimisation of ADRC parameters. A co‐simulation platform for a 5 MW FOWT was constructed using Simulink and OPENFAST, with the system's dynamic behaviour visualised via ParaView. Simulation results demonstrated that the proposed method reduced the THD of grid‐connected voltage and current to 2.46% and 0.91%, respectively. Moreover, hardware‐in‐the‐loop (HIL) experiments further verified the practical feasibility and effectiveness of the proposed control system.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 20 (1) , e70343
Edge Intelligence‐Supported Programmable Hardware System for PV‐Storage‐Load Microgrids
This paper proposes an edge intelligence‐supported programmable hardware system (EI‐PHS) for photovoltaic (PV)‐storage‐load microgrids. The platform enables hardware‐level validation of high‐level microgrid optimization algorithms and artificial intelligence (AI) models, thereby bridging the gap between algorithm development and physical deployment. A unified hardware–software co‐design framework is established by integrating programmable DC/DC converters, an edge AI module, and controller area network‐based communication, supporting the real‐time implementation of diverse scheduling, forecasting and energy‐management algorithms. The proposed EI‐PHS also provides highly programmable emulation of PV generation, battery charge/discharge dynamics and load behaviour, allowing flexible and reproducible construction of various microgrid operating scenarios using a simplified experimental setup. The effectiveness of the EI‐PHS is validated through four hardware case studies. These include programmable emulation of PV, battery and load behaviours; conventional system‐level power balancing; reinforcement learning‐based battery arbitrage; and spatio‐temporal graph neural network‐based forecasting and power balancing. In the two AI‐based cases, the hardware measurements closely match the simulation references, with mean absolute errors of 0.027 to 0.107 W and root mean square errors of 0.040 to 0.149 W. Only minor deviations are observed during rapid power transitions, confirming that the proposed EI‐PHS can accurately and reproducibly implement both conventional and AI‐based microgrid algorithms.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 20 (1) , e70343
Open AccessEdge Intelligence‐Supported Programmable Hardware System for PV‐Storage‐Load Microgrids
This paper proposes an edge intelligence‐supported programmable hardware system (EI‐PHS) for photovoltaic (PV)‐storage‐load microgrids. The platform enables hardware‐level validation of high‐level microgrid optimization algorithms and artificial intelligence (AI) models, thereby bridging the gap between algorithm development and physical deployment. A unified hardware–software co‐design framework is established by integrating programmable DC/DC converters, an edge AI module, and controller area network‐based communication, supporting the real‐time implementation of diverse scheduling, forecasting and energy‐management algorithms. The proposed EI‐PHS also provides highly programmable emulation of PV generation, battery charge/discharge dynamics and load behaviour, allowing flexible and reproducible construction of various microgrid operating scenarios using a simplified experimental setup. The effectiveness of the EI‐PHS is validated through four hardware case studies. These include programmable emulation of PV, battery and load behaviours; conventional system‐level power balancing; reinforcement learning‐based battery arbitrage; and spatio‐temporal graph neural network‐based forecasting and power balancing. In the two AI‐based cases, the hardware measurements closely match the simulation references, with mean absolute errors of 0.027 to 0.107 W and root mean square errors of 0.040 to 0.149 W. Only minor deviations are observed during rapid power transitions, confirming that the proposed EI‐PHS can accurately and reproducibly implement both conventional and AI‐based microgrid algorithms.
- Open Access
- 24 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Statistical approach to deadband estimation to inform TESS energy specification
The increasing use of renewable energy and decreasing inertia from large generators necessitate studying transient energy storage systems (TESSs) for better frequency stability. This paper examines UK National Grid data from 2014 to 2022 to propose initial design requirements for a TESS power‐train. It assesses second‐by‐second historical frequency data across various time frames to explore the impact on TESS sizing and strategies using the enhanced frequency response service 1 approach. The results establish an approach for determining the suitable battery energy capacity of TESSs offering frequency control services, contributing to the reduction of power demand and energy losses in the distribution grid. Moreover, the study presents a suitable deadband strategy for the enhanced frequency response service. The findings provide insights into the design and operational needs of TESSs in supporting grid frequency response, utilizing a statistical methodology driven by frequency data from the UK transmission network managed by National Grid Electricity Transmission. The primary aims of the paper are (a) to develop a suitable power and energy management philosophy for TESSs and thus inform future control objectives, and (b) assess the system energy specification requirements.
- 24 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 19 (1)
Open AccessStatistical approach to deadband estimation to inform TESS energy specification
The increasing use of renewable energy and decreasing inertia from large generators necessitate studying transient energy storage systems (TESSs) for better frequency stability. This paper examines UK National Grid data from 2014 to 2022 to propose initial design requirements for a TESS power‐train. It assesses second‐by‐second historical frequency data across various time frames to explore the impact on TESS sizing and strategies using the enhanced frequency response service 1 approach. The results establish an approach for determining the suitable battery energy capacity of TESSs offering frequency control services, contributing to the reduction of power demand and energy losses in the distribution grid. Moreover, the study presents a suitable deadband strategy for the enhanced frequency response service. The findings provide insights into the design and operational needs of TESSs in supporting grid frequency response, utilizing a statistical methodology driven by frequency data from the UK transmission network managed by National Grid Electricity Transmission. The primary aims of the paper are (a) to develop a suitable power and energy management philosophy for TESSs and thus inform future control objectives, and (b) assess the system energy specification requirements.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 19 (1)
Multicondition Health Condition Assessment for Electric Motors Based on Knowledge Embedding Machine Learning and Statistical Data Fusion
In industrial applications, motor operational status is crucial for production efficiency. However, timely detection and prediction of motor faults present significant challenges, often resulting in production incidents and substantial maintenance costs. This paper presents a novel approach for assessing motor equipment health based on knowledge‐embedded machine learning and statistical data evaluation. Specifically, the methodology first employs mechanism‐based motor operational models and statistical methods to identify key variable parameters associated with typical operational states from extensive monitoring variables, serving as input layers for machine learning algorithms. Subsequently, the study utilises machine learning algorithms to predict labels for normal operation, phase loss faults and overload faults, incorporating health degradation levels as knowledge‐embedded foundations for the health state assessment. Finally, the Comprehensive Health Index (CHI) was evaluated, achieving 98.1% health assessment accuracy on test datasets in environments with data sampling frequencies below 1 Hz and relatively low data quality. This methodology establishes relationships between health states and actual fault records through a dynamic weight allocation strategy that provides quantified percentage values, reflecting actual equipment usage patterns and degradation trends. It bridges the gap between theoretical diagnostic accuracy and practical industrial implementation requirements, providing highly robust maintenance strategies for industrial scenarios.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 19 (1)
Open AccessMulticondition Health Condition Assessment for Electric Motors Based on Knowledge Embedding Machine Learning and Statistical Data Fusion
In industrial applications, motor operational status is crucial for production efficiency. However, timely detection and prediction of motor faults present significant challenges, often resulting in production incidents and substantial maintenance costs. This paper presents a novel approach for assessing motor equipment health based on knowledge‐embedded machine learning and statistical data evaluation. Specifically, the methodology first employs mechanism‐based motor operational models and statistical methods to identify key variable parameters associated with typical operational states from extensive monitoring variables, serving as input layers for machine learning algorithms. Subsequently, the study utilises machine learning algorithms to predict labels for normal operation, phase loss faults and overload faults, incorporating health degradation levels as knowledge‐embedded foundations for the health state assessment. Finally, the Comprehensive Health Index (CHI) was evaluated, achieving 98.1% health assessment accuracy on test datasets in environments with data sampling frequencies below 1 Hz and relatively low data quality. This methodology establishes relationships between health states and actual fault records through a dynamic weight allocation strategy that provides quantified percentage values, reflecting actual equipment usage patterns and degradation trends. It bridges the gap between theoretical diagnostic accuracy and practical industrial implementation requirements, providing highly robust maintenance strategies for industrial scenarios.
- Open Access
- 4 December 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (S1) , 4679-4688
Transient energy storage systems for fast frequency response: Power‐train considerations
Renewable energy sources generate power intermittently, which poses challenges in meeting power demand. The use of transient energy storage systems (TESSs) has proven to be an effective solution to this issue. Hence, it is crucial to understand the impact of TESS components design on sizing the power‐train system during fast frequency response. While power‐train systems have been extensively discussed, the impact of dc‐link voltage on the TESS power‐* train and associated power electronics specification requirements has not been evaluated. This study uses a sodium‐nickel chloride (NaNiCl 2 ) battery‐based TESS to assess different power‐train options. Specifically, the research investigates the impact of variations in dc‐link voltage due to battery regulation and state‐of‐charge (SoC) on the design of the TESS‐connected power‐train system, since these will be the major contributions to the power‐train system performance envelope. This paper also compares the performance of TESS power‐train systems with four different schemes. The power‐train models include the detailed modelling of energy sources, power electronic converters, and transformers based on published parameters and testing data. Additionally, the study proposes a performance index to evaluate the superiority of the four schemes in terms of voltage and current rating, efficiency and battery size.
- 4 December 2024
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 18 (S1) , 4679-4688
Open AccessTransient energy storage systems for fast frequency response: Power‐train considerations
Renewable energy sources generate power intermittently, which poses challenges in meeting power demand. The use of transient energy storage systems (TESSs) has proven to be an effective solution to this issue. Hence, it is crucial to understand the impact of TESS components design on sizing the power‐train system during fast frequency response. While power‐train systems have been extensively discussed, the impact of dc‐link voltage on the TESS power‐* train and associated power electronics specification requirements has not been evaluated. This study uses a sodium‐nickel chloride (NaNiCl 2 ) battery‐based TESS to assess different power‐train options. Specifically, the research investigates the impact of variations in dc‐link voltage due to battery regulation and state‐of‐charge (SoC) on the design of the TESS‐connected power‐train system, since these will be the major contributions to the power‐train system performance envelope. This paper also compares the performance of TESS power‐train systems with four different schemes. The power‐train models include the detailed modelling of energy sources, power electronic converters, and transformers based on published parameters and testing data. Additionally, the study proposes a performance index to evaluate the superiority of the four schemes in terms of voltage and current rating, efficiency and battery size.
- 25 November 2016
- Published by Springer Nature
- p. 337-342
Picture Reconstruction Methods Based on Multilayer Perceptrons
- 25 November 2016
- Published by Springer Nature
- p. 337-342
Picture Reconstruction Methods Based on Multilayer Perceptrons