Amir Mohidin R. Demachkia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Amir Mohidin R. Demachkia has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Ali Barakat
Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia
2 shared publications- Salah A. Yousief
Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh 13313, Saudi Arabia
2 shared publications Abdulaziz Samran
Department of Restorative and Prosthetic Dental Sciences, College of Dentistry, Dar Al Uloom University, Riyadh, Saudi Arabia
1 shared publicationAhmed Mohammed Sleem Abdelglel
Deprtment of Fixed Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Assuit Branch, Cairo, Egypt
1 shared publicationAhmed S. Waly
Division of Pediatric Dentistry and Dental Public Health, Department of Pediatric Dentistry, Faculty of Dentistry, Al-Azhar University, Assiut, Egypt
1 shared publicationAmir M. Demachkia
Department of Dental Materials and Prosthodontics, São Paulo State University (UNESP), São José dos Campos, Brazil
1 shared publication
Latest Publications
- Open Access
- 2 May 2025
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 19 (04) , 903-918
Assessing Precision in All-Ceramic Fixed Restorations: Unveiling the Marginal Fit Through Digital and Traditional Impressions—A Comprehensive Systematic Review and Meta-Analysis
The marginal fit of all-ceramic fixed restorations is critical to long-term success. This comprehensive study and meta-analysis assessed the marginal fit of restorations manufactured using digital versus conventional impression procedures. We conducted a comprehensive search of electronic databases such as PubMed, Cochrane CENTRAL, Web of Science, and Scopus for publications published up to 2023. Eligible papers comparing the marginal fit of all-ceramic permanent restorations made using digital and conventional impressions were considered. A total of 19 studies met the inclusion criteria. The pooled analysis revealed that restorations fabricated from digital impressions exhibited a significantly better marginal fit than those from conventional impressions and showed a mean marginal gap of –13.76 µm (95% confidence interval: [–24.77, –2.76], p-value = 0.01). Subgroup analysis by type of digital impression system demonstrated consistent superiority of zironica material over other ones. However, high heterogeneity was observed among the included studies (I 2 = 90.74%). Digital impression restorations show superior marginal fit compared with conventional impressions, but high heterogeneity requires cautious interpretation and further well-designed studies to validate results. Article published online: 02 May 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- 2 May 2025
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 19 (04) , 903-918
Open AccessAssessing Precision in All-Ceramic Fixed Restorations: Unveiling the Marginal Fit Through Digital and Traditional Impressions—A Comprehensive Systematic Review and Meta-Analysis
The marginal fit of all-ceramic fixed restorations is critical to long-term success. This comprehensive study and meta-analysis assessed the marginal fit of restorations manufactured using digital versus conventional impression procedures. We conducted a comprehensive search of electronic databases such as PubMed, Cochrane CENTRAL, Web of Science, and Scopus for publications published up to 2023. Eligible papers comparing the marginal fit of all-ceramic permanent restorations made using digital and conventional impressions were considered. A total of 19 studies met the inclusion criteria. The pooled analysis revealed that restorations fabricated from digital impressions exhibited a significantly better marginal fit than those from conventional impressions and showed a mean marginal gap of –13.76 µm (95% confidence interval: [–24.77, –2.76], p-value = 0.01). Subgroup analysis by type of digital impression system demonstrated consistent superiority of zironica material over other ones. However, high heterogeneity was observed among the included studies (I 2 = 90.74%). Digital impression restorations show superior marginal fit compared with conventional impressions, but high heterogeneity requires cautious interpretation and further well-designed studies to validate results. Article published online: 02 May 2025 © 2025. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
- Open Access
- 10 December 2024
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 19 (03) , 667-677
Assessment of Stress Distribution Around Traditional and Sleeve Fixed Partial Denture Designs: Finite Element Analysis
Objectives The aim of this research is to evaluate/compare the use of traditional versus sleeve fixed partial denture (PD) designs made from different materials on supporting structures. The comparison included three- and four-unit PD cases. Materials and Methods Four finite element models are used in the research. The three-unit PD consists of the mandibular second premolar, first molar (as a pontic), and second molar. The four-unit PD includes the first premolar. The PD materials assessed were zirconia, E-max, and Celtra Duo. Bone has been simplified representing it as two cuboids. Each PD has been loaded to two cases over the pontic's central fossa: 300 N compressive, 150 N obliquely applied with 45 degrees forming 24 cases. Results The three-unit traditional and sleeve PDs material change showed a slight change in cortical bone stress under vertical loading. Under oblique loading, cortical bone Von Mises stresses were higher by about 12 to 15% more than vertical loading. On the other hand, the four-unit PDs showed minor effect by changing PD material, while using sleeve design PD can reduce the cortical bone stresses up to 20% in comparison to traditional PD design. The mucosa and spongy bone were negligibly affected by changing PD material, and the traditional and sleeve designs showed close values to each other. Superiority of sleeve design appeared by reducing cement layer stresses dramatically, while PD body material rigidity affects its response. Conclusion Within the limitations of this study, the higher rigid PD material can dissipate loadings over it more preferably regarding its effect on the underlying structures. Sleeve PD design is equivalent to the traditional one for three-unit PDs, while it showed better performance with four-unit PDs. Zirconia three-unit PDs' bodies received the lowest stresses and redistributed and transferred the applied load to the underneath structures better than the other two tested materials. This finding was reversed with four-unit PDs.
- 10 December 2024
- Published by Georg Thieme Verlag KG in European Journal of Dentistry
- Vol. 19 (03) , 667-677
Open AccessAssessment of Stress Distribution Around Traditional and Sleeve Fixed Partial Denture Designs: Finite Element Analysis
Objectives The aim of this research is to evaluate/compare the use of traditional versus sleeve fixed partial denture (PD) designs made from different materials on supporting structures. The comparison included three- and four-unit PD cases. Materials and Methods Four finite element models are used in the research. The three-unit PD consists of the mandibular second premolar, first molar (as a pontic), and second molar. The four-unit PD includes the first premolar. The PD materials assessed were zirconia, E-max, and Celtra Duo. Bone has been simplified representing it as two cuboids. Each PD has been loaded to two cases over the pontic's central fossa: 300 N compressive, 150 N obliquely applied with 45 degrees forming 24 cases. Results The three-unit traditional and sleeve PDs material change showed a slight change in cortical bone stress under vertical loading. Under oblique loading, cortical bone Von Mises stresses were higher by about 12 to 15% more than vertical loading. On the other hand, the four-unit PDs showed minor effect by changing PD material, while using sleeve design PD can reduce the cortical bone stresses up to 20% in comparison to traditional PD design. The mucosa and spongy bone were negligibly affected by changing PD material, and the traditional and sleeve designs showed close values to each other. Superiority of sleeve design appeared by reducing cement layer stresses dramatically, while PD body material rigidity affects its response. Conclusion Within the limitations of this study, the higher rigid PD material can dissipate loadings over it more preferably regarding its effect on the underlying structures. Sleeve PD design is equivalent to the traditional one for three-unit PDs, while it showed better performance with four-unit PDs. Zirconia three-unit PDs' bodies received the lowest stresses and redistributed and transferred the applied load to the underneath structures better than the other two tested materials. This finding was reversed with four-unit PDs.