S. Olof Mundt-Petersen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
S. Olof Mundt-Petersen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Petter Wallentén
Lund University
3 shared publications Johan Öberg
2 shared publications- Johan Öberg2 shared publications
- Nilla Olsson
NCC Sverige AB
2 shared publications - Pei-Yu Wu
RISE Research Institutes of Sweden, 412 58 Gothenburg, Sweden
2 shared publications Ida Edskär
1 shared publication
Latest Publications
- Open Access
- 21 August 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Evaluation of hygrothermal calculation models for ventilated roofs
- 21 August 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Open AccessEvaluation of hygrothermal calculation models for ventilated roofs
- Open Access
- 12 June 2026
- Published by Elsevier in SSRN Electronic Journal
Evaluation of hygrothermal calculation models for ventilated roofs
Hygrothermal simulations are a key tool for assessing moisture risks in ventilated roof constructions, but their reliability is highly sensitive to modelling assumptions. This study systematically evaluates the performance of one-dimensional hygrothermal models for ventilated roofs by comparing simulation results with long-term field measurements from two Swedish buildings representing different roof and attic configurations.The analysis investigates the influence of air change rate (ACH), radiation modelling, air-layer representation, and simplified treatments of snow. Model accuracy is assessed using the composite JGAP metric, which integrates agreement in temperature, relative humidity, and moisture content. Across all cases, ACH is identified as the governing parameter, although its effect differs between variables: higher ACH improves temperature predictions, while relative humidity is best captured at moderate levels.A consistent finding is the overestimation of solar heat gains, particularly for south-facing roofs, which leads to systematic temperature bias. The use of an equivalent IBP model for tiled roofs significantly improves agreement by better representing combined radiative and convective heat transfer, especially at low ventilation rates. Snow modelling shows limited and case-dependent impact, reflecting both climatic variability and modelling simplifications.The study proposes practical ACH ranges for different roof configurations and demonstrates that well-calibrated one-dimensional models can provide robust decision support in engineering practice. However, it is emphasized that ACH must be interpreted as an effective model parameter rather than a direct physical measurement, and that accurate radiation modelling is critical for reliable results.
- 12 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEvaluation of hygrothermal calculation models for ventilated roofs
Hygrothermal simulations are a key tool for assessing moisture risks in ventilated roof constructions, but their reliability is highly sensitive to modelling assumptions. This study systematically evaluates the performance of one-dimensional hygrothermal models for ventilated roofs by comparing simulation results with long-term field measurements from two Swedish buildings representing different roof and attic configurations.The analysis investigates the influence of air change rate (ACH), radiation modelling, air-layer representation, and simplified treatments of snow. Model accuracy is assessed using the composite JGAP metric, which integrates agreement in temperature, relative humidity, and moisture content. Across all cases, ACH is identified as the governing parameter, although its effect differs between variables: higher ACH improves temperature predictions, while relative humidity is best captured at moderate levels.A consistent finding is the overestimation of solar heat gains, particularly for south-facing roofs, which leads to systematic temperature bias. The use of an equivalent IBP model for tiled roofs significantly improves agreement by better representing combined radiative and convective heat transfer, especially at low ventilation rates. Snow modelling shows limited and case-dependent impact, reflecting both climatic variability and modelling simplifications.The study proposes practical ACH ranges for different roof configurations and demonstrates that well-calibrated one-dimensional models can provide robust decision support in engineering practice. However, it is emphasized that ACH must be interpreted as an effective model parameter rather than a direct physical measurement, and that accurate radiation modelling is critical for reliable results.
- 22 February 2026
- Published by Springer Nature
- p. 869-884
State-of-the-Art – Different Approaches Assessing Damage and Causes of Damage in Buildings
- 22 February 2026
- Published by Springer Nature
- p. 869-884
State-of-the-Art – Different Approaches Assessing Damage and Causes of Damage in Buildings
- 30 January 2026
- Published by Springer Nature
- p. 464-476
Deviations Caused by Time Shifts When Comparing Measured and Calculated Temperature and Relative Humidity
- 30 January 2026
- Published by Springer Nature
- p. 464-476
Deviations Caused by Time Shifts When Comparing Measured and Calculated Temperature and Relative Humidity
- Open Access
- 23 January 2026
- Published by Springer Nature in Journal of Building Pathology and Rehabilitation
- Vol. 11 (2) , 97
Quantifying the impact of inadequate building management and maintenance on damage, failures and functional defects
Damage, failures, and defects in buildings create an enormous cost for stakeholders. This study examined technical aspects of inadequate management and maintenance causing moisture and indoor environment related damage instances. Using a dataset of 2100 diagnosed causes of damage based on real damage investigations carried out in Sweden, several of the factors causing damage were identified. The collected causes of damage in the dataset were cross-compared to several parameters and variables. Almost one-fourth of all building damage resulted from inadequate management and maintenance, with 87% of these cases being the responsibility of property owners or their trustees. In total, 38% of the management and maintenance-related damage was found to be associated with building services systems, such as inadequate stormwater treatment or defective ventilation. Furthermore, a high proportion of damage (20%) was attributed to an exceeded technical service life, particularly in roofing and terrace membranes, walls, and doors. Rain and snow were the most common sources causing damage in the management phase. A high portion of the causes of damage were on an elementary level and should be easily avoidable, such as insufficient cleaning of ventilation pipes and gutters, or worn-out building components where the technical service life was exceeded. Based on the results, a list of recommendations for preventive actions was made.
- 23 January 2026
- Published by Springer Nature in Journal of Building Pathology and Rehabilitation
- Vol. 11 (2) , 97
Open AccessQuantifying the impact of inadequate building management and maintenance on damage, failures and functional defects
Damage, failures, and defects in buildings create an enormous cost for stakeholders. This study examined technical aspects of inadequate management and maintenance causing moisture and indoor environment related damage instances. Using a dataset of 2100 diagnosed causes of damage based on real damage investigations carried out in Sweden, several of the factors causing damage were identified. The collected causes of damage in the dataset were cross-compared to several parameters and variables. Almost one-fourth of all building damage resulted from inadequate management and maintenance, with 87% of these cases being the responsibility of property owners or their trustees. In total, 38% of the management and maintenance-related damage was found to be associated with building services systems, such as inadequate stormwater treatment or defective ventilation. Furthermore, a high proportion of damage (20%) was attributed to an exceeded technical service life, particularly in roofing and terrace membranes, walls, and doors. Rain and snow were the most common sources causing damage in the management phase. A high portion of the causes of damage were on an elementary level and should be easily avoidable, such as insufficient cleaning of ventilation pipes and gutters, or worn-out building components where the technical service life was exceeded. Based on the results, a list of recommendations for preventive actions was made.
- 14 December 2024
- Published by Springer Nature
- p. 105-113
Probabilistic Distributions of Moisture Damages in Swedish Buildings
- 14 December 2024
- Published by Springer Nature
- p. 105-113
Probabilistic Distributions of Moisture Damages in Swedish Buildings