István Hritz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
István Hritz has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Bálint Gellért
Department of Surgery, Transplantation and Gastroenterology, Division of Interventional Gastroenterology, Semmelweis University, 1082 Budapest, Hungary
2 shared publications Anett Rancz
Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
1 shared publication- Attila Szijártó
Department of Surgery, Transplantation and Gastroenterology, Semmelweis University, 1082 Budapest, Hungary
1 shared publication Brigitta Teutsch
Centre for Translational Medicine, Semmelweis University, Budapest, Hungary
1 shared publication- Bánk Keczer
Department of Surgery, Transplantation and Gastroenterology, Semmelweis University, 1082 Budapest, Hungary
1 shared publication Dániel S. Veres
Department of Biophysics and Radiation Biology, Semmelweis University, Budapest, Hungary
1 shared publication
Latest Publications
- Open Access
- 7 December 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (24) , 8671
Clinical Benefits of KRAS/GNAS Gene Mutation Analysis in Addition to Morphology and Conventional Cyst Fluid Testing in Differentiating Pancreatic Cysts
Objectives: Pancreatic cystic lesions (PCLs) are increasingly detected due to the widespread use of imaging techniques. The identification of pancreatic mucinous cysts is especially important since these carry a risk of malignant transformation and require follow-up or surgical resection. The aim of this study was to determine the diagnostic yield of the molecular analysis of K-RAS (Kirsten RAt Sarcoma virus) and GNAS (Guanine Nucleotide-binding protein, Alpha Stimulating protein activity) gene mutations in pancreatic cyst fluid (PCF) obtained by endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA). Methods: In this prospective trial, we assessed the sensitivity, specificity, and positive and negative predictive values of K-RAS and GNAS mutation analysis in differentiating mucinous versus non-mucinous cysts and the subsequent impact on decision-making in daily clinical practice. The reference standard used comprised the combination of morphology on cross-sectional imaging and EUS, string sign, cyst fluid cytology, intracystic carcinoembryonic antigen (CEA), and glucose levels, with subsequent correlation of surgical pathology in resected cases. Fluid samples of 47 cysts obtained by EUS-FNA over a 39-month period were analyzed. Mutation analysis of KRAS (exon 2) was performed in all cases, and additionally, GNAS (exon 8) in 28 cases using Sanger sequencing. Results: 33 out of 47 PCLs were classified as mucinous cysts and 14 as non-mucinous cysts defined using conventional standards, including morphological characteristics, string-sign, cytology, cyst fluid testing, and histology in resected cases. Of these 33 mucinous cysts, KRAS mutation was detected in 14 samples. A further 23 mucinous lesions were additionally tested for GNAS mutation, which was detected in 10 of the 23 cysts. A 42.4% sensitivity for KRAS and 43.5% for GNAS mutation analysis was calculated, with a specificity of 92.9% and 100%, respectively, for detecting mucinous lesions. The clinical management was altered through the genetic testing results in one single case. Conclusions: In this cohort, K-RAS and GNAS mutational analysis in cyst fluid did not improve the detection of mucinous pancreatic cysts significantly after conventional testing. However, the method may be useful due to its high specificity in uncertain cases.
- 7 December 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (24) , 8671
Open AccessClinical Benefits of KRAS/GNAS Gene Mutation Analysis in Addition to Morphology and Conventional Cyst Fluid Testing in Differentiating Pancreatic Cysts
Objectives: Pancreatic cystic lesions (PCLs) are increasingly detected due to the widespread use of imaging techniques. The identification of pancreatic mucinous cysts is especially important since these carry a risk of malignant transformation and require follow-up or surgical resection. The aim of this study was to determine the diagnostic yield of the molecular analysis of K-RAS (Kirsten RAt Sarcoma virus) and GNAS (Guanine Nucleotide-binding protein, Alpha Stimulating protein activity) gene mutations in pancreatic cyst fluid (PCF) obtained by endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA). Methods: In this prospective trial, we assessed the sensitivity, specificity, and positive and negative predictive values of K-RAS and GNAS mutation analysis in differentiating mucinous versus non-mucinous cysts and the subsequent impact on decision-making in daily clinical practice. The reference standard used comprised the combination of morphology on cross-sectional imaging and EUS, string sign, cyst fluid cytology, intracystic carcinoembryonic antigen (CEA), and glucose levels, with subsequent correlation of surgical pathology in resected cases. Fluid samples of 47 cysts obtained by EUS-FNA over a 39-month period were analyzed. Mutation analysis of KRAS (exon 2) was performed in all cases, and additionally, GNAS (exon 8) in 28 cases using Sanger sequencing. Results: 33 out of 47 PCLs were classified as mucinous cysts and 14 as non-mucinous cysts defined using conventional standards, including morphological characteristics, string-sign, cytology, cyst fluid testing, and histology in resected cases. Of these 33 mucinous cysts, KRAS mutation was detected in 14 samples. A further 23 mucinous lesions were additionally tested for GNAS mutation, which was detected in 10 of the 23 cysts. A 42.4% sensitivity for KRAS and 43.5% for GNAS mutation analysis was calculated, with a specificity of 92.9% and 100%, respectively, for detecting mucinous lesions. The clinical management was altered through the genetic testing results in one single case. Conclusions: In this cohort, K-RAS and GNAS mutational analysis in cyst fluid did not improve the detection of mucinous pancreatic cysts significantly after conventional testing. However, the method may be useful due to its high specificity in uncertain cases.
- Open Access
- 13 December 2024
- Published by Springer Nature in Obesity Surgery
- Vol. 35 (1) , 285-304
Understanding the Role of Different ERCP Techniques in Post-Roux-en-Y Gastric Bypass Patients: a Systematic Review and Meta-analysis
We aimed to compare enteroscopy-assisted ERCP (EA-ERCP), laparoscopy-assisted ERCP (LA-ERCP), and endoscopic ultrasound-directed ERCP (EDGE) in terms of safety and efficacy in post-Roux-en-Y gastric bypass patients. We conducted a rigorous analysis based on a predefined protocol (PROSPERO, CRD42022368788). Sixty-seven studies were included. The technical success rates were 77% (CI 69–83%) for EA-ERCP, 93% (CI 91–96%) for LA-ERCP, and 96% (CI 92–98%) for EDGE. Subgroup differences were significant between the EA-ERCP and other groups (p < 0.05). The overall adverse event rates were 13% (CI 8–22%), 19% (CI 14–24%), and 20% (CI 12–31%), respectively (p = 0.49). Our findings suggest that EDGE and LA-ERCP may be more effective and as safe as EA-ERCP. Graphical abstract
- 13 December 2024
- Published by Springer Nature in Obesity Surgery
- Vol. 35 (1) , 285-304
Open AccessUnderstanding the Role of Different ERCP Techniques in Post-Roux-en-Y Gastric Bypass Patients: a Systematic Review and Meta-analysis
We aimed to compare enteroscopy-assisted ERCP (EA-ERCP), laparoscopy-assisted ERCP (LA-ERCP), and endoscopic ultrasound-directed ERCP (EDGE) in terms of safety and efficacy in post-Roux-en-Y gastric bypass patients. We conducted a rigorous analysis based on a predefined protocol (PROSPERO, CRD42022368788). Sixty-seven studies were included. The technical success rates were 77% (CI 69–83%) for EA-ERCP, 93% (CI 91–96%) for LA-ERCP, and 96% (CI 92–98%) for EDGE. Subgroup differences were significant between the EA-ERCP and other groups (p < 0.05). The overall adverse event rates were 13% (CI 8–22%), 19% (CI 14–24%), and 20% (CI 12–31%), respectively (p = 0.49). Our findings suggest that EDGE and LA-ERCP may be more effective and as safe as EA-ERCP. Graphical abstract