Tobias Krille
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tobias Krille has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Rico Poser
Institute of Aerospace Thermodynamics, Faculty of Aerospace Engineering and Geodesy, University of Stuttgart, 70569 Stuttgart, Germany
4 shared publications Jens von Wolfersdorf
Univ Stuttgart, Inst Aerosp Thermodynam ITLR, Stuttgart, Germany
2 shared publications- Jens von Wolfersdorf
ITLR, University of Stuttgart Pfaffenwaldring 31 70569 Stuttgart
2 shared publications Marc Henze
2 shared publicationsRico Poser
Univ Stuttgart, Inst Aerosp Thermodynam ITLR, Stuttgart, Germany
2 shared publications- Stefan Retzko
Ansaldo Energia Switzerland AG, Römerstrasse 36, Baden 5400, Switzerland
2 shared publications
Latest Publications
- Open Access
- 6 December 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 202
An experimental investigation on pressure loss and local heat transfer characteristics in additively manufactured ribbed cooling configurations
- 6 December 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 202
Open AccessAn experimental investigation on pressure loss and local heat transfer characteristics in additively manufactured ribbed cooling configurations
- Open Access
- 1 April 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 185
An experimental approach to determine local heat transfer characteristics in additively manufactured cooling configurations
- 1 April 2022
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 185
Open AccessAn experimental approach to determine local heat transfer characteristics in additively manufactured cooling configurations
- Open Access
- 29 March 2022
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 345, 01003
Conduction and Inertia Correction for Transient Thermocouple Measurements. Part II: Experimental Validation and Application
Thermocouples are often used for temperature measurements. Under transient conditions, measurement errors can occur due to capacitive inertia and heat conduction along the stem of the thermocouples. To correct such errors, a method is presented in Part I [1] of this paper, which uses a simplified analytical approach and a numerical solution. In the present work, this method is applied to temperature measurements. Several experiments with different thermocouple designs were performed to investigate different conditions such as installation depth, thermocouple type and transient temperature rises. In all cases, two thermocouples were placed so that they are exposed to the same fluid temperature. They are installed with short or long immersion length, respectively. It is shown that only the short thermocouple experiences a thermal conduction error, but both are subject to thermal inertia. The importance of compensating for these effects is shown by quantifying the errors in a typical heat transfer experiment when they are neglected. It is shown, which parameters are necessary for a re-calculation of fluid temperatures when two thermocouples are present at the same measuring position. Furthermore, a simplified method is described, which can be applied if the instrumentation of only one thermocouple is possible.
- 29 March 2022
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 345, 01003
Open AccessConduction and Inertia Correction for Transient Thermocouple Measurements. Part II: Experimental Validation and Application
Thermocouples are often used for temperature measurements. Under transient conditions, measurement errors can occur due to capacitive inertia and heat conduction along the stem of the thermocouples. To correct such errors, a method is presented in Part I [1] of this paper, which uses a simplified analytical approach and a numerical solution. In the present work, this method is applied to temperature measurements. Several experiments with different thermocouple designs were performed to investigate different conditions such as installation depth, thermocouple type and transient temperature rises. In all cases, two thermocouples were placed so that they are exposed to the same fluid temperature. They are installed with short or long immersion length, respectively. It is shown that only the short thermocouple experiences a thermal conduction error, but both are subject to thermal inertia. The importance of compensating for these effects is shown by quantifying the errors in a typical heat transfer experiment when they are neglected. It is shown, which parameters are necessary for a re-calculation of fluid temperatures when two thermocouples are present at the same measuring position. Furthermore, a simplified method is described, which can be applied if the instrumentation of only one thermocouple is possible.
- Open Access
- 16 July 2021
- Published by ASME International
Heat Transfer Measurements Using Multiple Thermochromic Liquid Crystals in Symmetric Cooling Channels
- 16 July 2021
- Published by ASME International
Open AccessHeat Transfer Measurements Using Multiple Thermochromic Liquid Crystals in Symmetric Cooling Channels
- Open Access
- 16 July 2021
- Published by ASME International
Heat Transfer Measurements Using Multiple Thermochromic Liquid Crystals in Symmetric Cooling Channels
Division / Sponsor: International Gas Turbine Institute (IGTI)
- 16 July 2021
- Published by ASME International
Open AccessHeat Transfer Measurements Using Multiple Thermochromic Liquid Crystals in Symmetric Cooling Channels
Division / Sponsor: International Gas Turbine Institute (IGTI)
- Open Access
- 26 April 2021
- Published by Wiley in Journal of Turbomachinery
- Vol. 143 (8)
Heat Transfer Measurements Using Multiple Thermochromic Liquid Crystals in Symmetric Cooling Channels
The transient thermochromic liquid crystal (TLC) method is applied to determine the distribution of the local heat transfer coefficients using a configuration with parallel cooling channels at an engine-relevant Reynolds number. The rectangular channels with a moderate aspect ratio and a high length-to-diameter ratio are equipped with one-sided oblique ribs with high blockage, which is a promising configuration for turbine near-wall cooling applications. In this arrangement, the three inner channels should experience same flow and thermal conditions. Numerical simulations are performed to substantiate this assumption. The symmetric single channels are sprayed with narrowband TLC with various indication temperatures. Multiple experiments were conducted. All start at ambient conditions before the fluid is heated up to several temperatures between 46 °C and 73 °C. The results show that the determined local heat transfer coefficients and therefore the Nusselt numbers vary significantly for the different experimental conditions especially at locations of high heat transfer coefficient behind the ribs. A simplified procedure with respect to measurement uncertainties is applied to enable an easy and fast valuation of the data quality. This might be used within the data reduction analysis for such experiments directly. The approach is illustrated using the obtained experimental data.
- 26 April 2021
- Published by Wiley in Journal of Turbomachinery
- Vol. 143 (8)
Open AccessHeat Transfer Measurements Using Multiple Thermochromic Liquid Crystals in Symmetric Cooling Channels
The transient thermochromic liquid crystal (TLC) method is applied to determine the distribution of the local heat transfer coefficients using a configuration with parallel cooling channels at an engine-relevant Reynolds number. The rectangular channels with a moderate aspect ratio and a high length-to-diameter ratio are equipped with one-sided oblique ribs with high blockage, which is a promising configuration for turbine near-wall cooling applications. In this arrangement, the three inner channels should experience same flow and thermal conditions. Numerical simulations are performed to substantiate this assumption. The symmetric single channels are sprayed with narrowband TLC with various indication temperatures. Multiple experiments were conducted. All start at ambient conditions before the fluid is heated up to several temperatures between 46 °C and 73 °C. The results show that the determined local heat transfer coefficients and therefore the Nusselt numbers vary significantly for the different experimental conditions especially at locations of high heat transfer coefficient behind the ribs. A simplified procedure with respect to measurement uncertainties is applied to enable an easy and fast valuation of the data quality. This might be used within the data reduction analysis for such experiments directly. The approach is illustrated using the obtained experimental data.