Marco Puccini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marco Puccini has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Raffaele Scafè
Independent Researcher, Italy
4 shared publications - Roberto Pani
Sapienza University of Rome, Italy
4 shared publications - Rosanna Pellegrini
Dept. of Molecular Medicine, Sapienza University of Rome, Italy, Italy
4 shared publications
Latest Publications
- Open Access
- 29 October 2025
- Published by MDPI AG in Preprints.org
A Catalog of XRF-Escape Peaks from Radiation Detectors Compounds for Nuclear Molecular Medicine and Gamma-Ray Spectrometry
A catalog of values of predicted energies of the K-XRF escape-peaks from compounds, used for radiation detectors, is presented for given incident gamma-rays suited for nuclear molecular medicine and low-energy spectrometry. The information relating to the compounds adds to that relating to the individual natural elements recently posted [RSC2025a]. The results of powerfunctions best-fit of XRF energy values vs. Z are listed in Table 1 for Kα2 orbital and Kedge. These expressions, allow simple calculations, avoiding the development of complex software. An extensive literature survey has been carried out mainly considering text-books, review articles and research reports. A final number compounds (Nc) equal to 729 has been obtained, whose distribution per number of constituting elements (Ne) is reported in Table 2. The predicted energy peaks are arranged in Tables 3 to 7 per Ne in the range from 2 to 8, showing the average value of 3.92 elements per compound. The catalog is conceived for nuclear molecular medicine and gamma-ray spectrometry where such peaks need to be recognized and their underlying area known in order to allow quantitative information.
- 29 October 2025
- Published by MDPI AG in Preprints.org
Open AccessA Catalog of XRF-Escape Peaks from Radiation Detectors Compounds for Nuclear Molecular Medicine and Gamma-Ray Spectrometry
A catalog of values of predicted energies of the K-XRF escape-peaks from compounds, used for radiation detectors, is presented for given incident gamma-rays suited for nuclear molecular medicine and low-energy spectrometry. The information relating to the compounds adds to that relating to the individual natural elements recently posted [RSC2025a]. The results of powerfunctions best-fit of XRF energy values vs. Z are listed in Table 1 for Kα2 orbital and Kedge. These expressions, allow simple calculations, avoiding the development of complex software. An extensive literature survey has been carried out mainly considering text-books, review articles and research reports. A final number compounds (Nc) equal to 729 has been obtained, whose distribution per number of constituting elements (Ne) is reported in Table 2. The predicted energy peaks are arranged in Tables 3 to 7 per Ne in the range from 2 to 8, showing the average value of 3.92 elements per compound. The catalog is conceived for nuclear molecular medicine and gamma-ray spectrometry where such peaks need to be recognized and their underlying area known in order to allow quantitative information.
- Open Access
- 15 September 2025
- Published by MDPI AG in Preprints.org
XRF Escape-Peaks from Natural Elements for Nuclear Medicine Imaging and Gamma-Ray Spectrometry
A catalog of K-XRF escape-peak energy from natural elements and for several energies of gamma-rays incident on a single-element detector is presented. The parameters of a power-model are listed In Table I for predicting the energy of such peaks.In Table II predicted peaks are arranged in order of increasing atomic number (ranging from 4 to 92) of the detector component and for the Kα2 XRF main emission.This catalog is conceived for nuclear medicine and gamma-ray spectrometry where such peak need to be recognized and known as underlying area in order to gain advantage of quantitative analysis, but, also for detector-developers as well as for spectroscopists that should be interested in the issue.
- 15 September 2025
- Published by MDPI AG in Preprints.org
Open AccessXRF Escape-Peaks from Natural Elements for Nuclear Medicine Imaging and Gamma-Ray Spectrometry
A catalog of K-XRF escape-peak energy from natural elements and for several energies of gamma-rays incident on a single-element detector is presented. The parameters of a power-model are listed In Table I for predicting the energy of such peaks.In Table II predicted peaks are arranged in order of increasing atomic number (ranging from 4 to 92) of the detector component and for the Kα2 XRF main emission.This catalog is conceived for nuclear medicine and gamma-ray spectrometry where such peak need to be recognized and known as underlying area in order to gain advantage of quantitative analysis, but, also for detector-developers as well as for spectroscopists that should be interested in the issue.
- Open Access
XRF-Escape Scintillator Footprints for Nuclear Medicine Imaging and Gamma-Ray Spectrometry
The present paper introduces the so-called scintillator footprints, consisting of plots showing XRF-escape peaks and their relative emission intensities in the energy range of interest for nuclear medicine SPECT and PET. A footprint describes the suitability of a scintillator for quantitative investigation with the best possible detectability. Sixteen scintillation materials have been identified in the literature, characterized by effective atomic numbers Zeff ranging between 22 and 75. The footprints of NaI:Tl and BGO, confirm the best suitability for quantitative spectral analysis in SPECT and PET, at 140.5 keV and 511 keV, respectively. Moreover, for the low-Zeff scintillators like CaF2 and CMSM, the XRF-escape effect is to predict irrelevant even at 140.5 keV due to the small energy value of X-ray fluorescence.
Open AccessXRF-Escape Scintillator Footprints for Nuclear Medicine Imaging and Gamma-Ray Spectrometry
The present paper introduces the so-called scintillator footprints, consisting of plots showing XRF-escape peaks and their relative emission intensities in the energy range of interest for nuclear medicine SPECT and PET. A footprint describes the suitability of a scintillator for quantitative investigation with the best possible detectability. Sixteen scintillation materials have been identified in the literature, characterized by effective atomic numbers Zeff ranging between 22 and 75. The footprints of NaI:Tl and BGO, confirm the best suitability for quantitative spectral analysis in SPECT and PET, at 140.5 keV and 511 keV, respectively. Moreover, for the low-Zeff scintillators like CaF2 and CMSM, the XRF-escape effect is to predict irrelevant even at 140.5 keV due to the small energy value of X-ray fluorescence.
- Open Access
- 16 December 2024
- Published by MDPI AG in Preprints.org
XRF-Escape Scintillator Footprints for Nuclear Medicine Imaging and Gamma-Ray Spectrometry
The present paper introduces the so-called scintillators footprints, made of schemes showing XRF-escape peaks and their relative emission intensities in the energy range of interest for nuclear medicine SPECT and PET. A footprint describes the suitability of a scintillator for quantitative investigation with the best possible detectabilility. Sixteen scintillation materials have been identified in Literature, characterized by effective atomic number ranging between 22 to 75. The footprints of NaI:Tl and BGO, confirm the best suitability for quantitative spectral analisys at 140.5 keV and 511 keV, respectively. Moreover, for the low-Z eff scintillators like CaF 2 and CMSM, the XRF-escape effect is foresee irrelevant even at 140.5 keV, due to the small energy value of X-ray fluorescences.
- 16 December 2024
- Published by MDPI AG in Preprints.org
Open AccessXRF-Escape Scintillator Footprints for Nuclear Medicine Imaging and Gamma-Ray Spectrometry
The present paper introduces the so-called scintillators footprints, made of schemes showing XRF-escape peaks and their relative emission intensities in the energy range of interest for nuclear medicine SPECT and PET. A footprint describes the suitability of a scintillator for quantitative investigation with the best possible detectabilility. Sixteen scintillation materials have been identified in Literature, characterized by effective atomic number ranging between 22 to 75. The footprints of NaI:Tl and BGO, confirm the best suitability for quantitative spectral analisys at 140.5 keV and 511 keV, respectively. Moreover, for the low-Z eff scintillators like CaF 2 and CMSM, the XRF-escape effect is foresee irrelevant even at 140.5 keV, due to the small energy value of X-ray fluorescences.