DTDaojun Tan

Daojun Tan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daojun Tan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Repair-Based Improved Whale Optimization Algorithm for Low-Carbon Economic Dispatch of an Islanded Renewable Microgrid

    by Haozhe Xiong, Daojun Tan, Yiqun Kang, Li You, Fangbin Yan, Feng Liu, Qinyue Tan

    Islanded renewable microgrids must balance power internally, so day-ahead dispatch is affected by wind and photovoltaic variability, battery state-of-charge (SOC) dynamics, demand-response (DR) participation, and emissions from dispatchable generation. This paper proposes a low-carbon economic dispatch model for an islanded photovoltaic–wind-turbine–battery-energy-storage–dispatchable-generator–demand-response (PV-WT-BESS-DG-DR) microgrid. The objective includes fuel, operation and maintenance, BESS degradation, renewable curtailment, load shedding, DR compensation, and carbon-emission costs. A repair-based constraint-handling strategy keeps the search space continuous while enforcing power balance, DG ramping, BESS operating and SOC limits, terminal SOC, and DR constraints. An improved whale optimization algorithm (WOA) is then developed with three modules: diversity enhancement, exploration–exploitation balancing, and local escape and refinement. The method is assessed through base-case dispatch, benchmark comparison, strategy comparison, ablation tests, and sensitivity analysis. In 30 independent runs, the proposed method achieves a mean cost of 2662.96 CNY/day, 4.07% lower than standard WOA, and reduces the standard deviation by 79.72%. Wilcoxon and Friedman tests confirm significant differences from the benchmark algorithms. Sensitivity tests show that higher BESS degradation coefficients and carbon prices increase the accounting cost but do not change the qualitative feasibility of the deterministic dispatch framework.

  • Open Access

    Research on New Power Grid Simulation Technology Based on Cloud Edge Collaboration

    by Heng Luo, Daojun Tan, Kang Cao, Xuan Cai

    Power grid simulation and deduction technology is an important means to grasp the operating characteristics of the power grid and study power grid scheduling technology. A new type of power grid with a high proportion of distributed new energy access, where each distribution network transformer may become a power source or a load endpoint. Therefore, the entire power grid has become a dual directed graph network structure, and the traditional top-down simulation mode is difficult to adapt to. The paper constructs a new type of power grid simulation and deduction framework for cloud edge collaboration, and proposes an optimization algorithm for service caching and computation offloading under cloud edge collaboration, which improves the running speed of the simulation system, ensures the accuracy of electromagnetic transient simulation, enhances the simulation speed of large-scale complex power grids, and adapts to the high-frequency use and maintenance of simulation analysis in power grids.

  • Open Access

    Optimal Multiple Wind Power Transmission Schemes Based on a Life Cycle Cost Analysis Model

    by Xiaotong Ji, Dan Liu, Heng Luo, Ping Xiong, Daojun Tan, Pan Hu, Hengrui Ma, Bo Wang

    Due to the high cost and complex challenges faced by offshore wind power transmission, economic research into offshore wind power transmission can provide a scientific basis for optimal decision-making on offshore wind power projects. Based on the analysis of the topology structure and characteristics of typical wind power transmission schemes, this paper compares the economic benefits of five different transmission schemes with a 3.6 GW sizeable onshore wind farm as the primary case. Research includes traditional high voltage alternating current (HVAC), voltage source converter high voltage direct current transmission (VSC-HVDC), a fractional frequency transmission system (FFTS), and two hybrid DC (MMC-LCC and DR-MMC) transmission scenarios. The entire life cycle cost analysis model (LCCA) is employed to thoroughly assess the cumulative impact of initial investment costs, operational expenses, and eventual scrap costs on top of the overall transmission scheme’s total cost. This comprehensive evaluation ensures a nuanced understanding of the financial implications across the project’s entire lifespan. In this example, HVAC has an economic advantage over VSC-HVDC in the transmission distance range of 78 km, and the financial range of a FFTS is 78–117 km. DR-MMC is better than the flexible DC delivery scheme in terms of transmission capacity, scalability, and offshore working platform construction costs in the DC delivery scheme. Therefore, the hybrid DC delivery scheme of offshore wind power composed of multi-type converters has excellent application prospects.