MBMárcio Fernando Paixão de Brito

Márcio Fernando Paixão de Brito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Márcio Fernando Paixão de Brito has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of microporosity and density of carbonate rocks through experimental measurements using gamma-ray and x-ray computed tomography techniques

    by Wellington da Silva Carvalho, Daniel Milian Pérez, Abel Gámez Rodríguez, Yaicel Ge Proenza, Patrício Luiz de Andrade, Daniel Amancio Duarte, Márcio Fernando Paixão de Brito, Cássia Bezerra Machado, Raquel Milani, Antonio Celso Dantas Antonino

    Computed Tomography (CT) techniques have emerged as a promising non-destructive method to analyze the physical properties of rocks and porous media. CT techniques provide quantitative and qualitative information without disturbing the internal structure of the samples, which is a significant advantage for studies focused on understanding subsurface characteristics. This study investigates the potential and application of gamma-ray computed tomography (?-CT) and X-ray microtomography (XR-?CT) for characterizing the microporosity and density of rocks, specifically carbonate rocks. Accurate characterization of these properties is crucial for evaluating water reservoir potentials, understanding geological formations, and assessing environmental impacts. The research aimed to validate the accuracy of both techniques and assess the feasibility of using a single XR-?CT projection to determine physical properties, potentially reducing computational demands. Validation involved samples with homogeneous, known composition, determining density and mass attenuation coefficients with both techniques, and comparing results to literature values. ?-CT achieved accuracy within 1.86%, while single-projection XR-?CT showed relative differences up to 10.65%. Subsequently, three carbonate rock samples were analyzed using XR-?CT with an average of four projections, improving accuracy over the single-projection method. Results from both CT techniques were compared to each other and literature values, with ?-CT measuring parameters with a relative difference of up to 4.58%, and the four-projection XR-?CT showing strong accuracy. Relative differences in ?-CT were generally higher than XR-?CT, confirming the four-projection approach's significant improvements.

  • Characterization of material using dual-energy gamma-ray tomography: Determination of atomic number and density

    by Patrício Luiz de Andrade, Enivaldo Santos Barbosa, Daniel Milian Pérez, Abel Gámez Rodríguez, Marcio Fernando Paixão de Brito, Carlos Costa Dantas, Antonio Celso Dantas Antonino


  • Open Access

    Analysis of flow dynamics and velocity in circulating fluidized beds: non-invasive measurements with gamma radiation

    by Marcio Brito, Enivaldo Santos Barbosa, Carlos Costa Dantas, Antonio Celso Dantas Antonino

    This study introduces a non-invasive method for characterizing gas-solid flow in circulating fluidized bed (CFB) risers using gamma radiation transmission. By applying the Richardson-Zaki law and measuring radial gamma attenuation, the analysis quantifies FCC catalyst velocity profiles and solid holdup across varying flow conditions. Experiments explored the effects of superficial gas velocity (500–700 L/min), VPC valve openings (25–35%), and axial height on particle dynamics. Increasing the air flow rate raised catalyst velocity by up to 25%, while higher solid concentrations reduced velocity near the riser walls by approximately 22%. Velocity profiles exhibited parabolic shapes at lower positions and became uniform in the upper sections, confirming the establishment of fully developed core-annular flow. The method delivered results with high repeatability, showing less than 3% uncertainty across five repetitions. These findings provide a novel and precise tool for diagnosing flow regimes and optimizing riser performance in FCC and other multiphase process systems.

  • Open Access

    X-Ray Computed Tomography for Estimating Density and Porosity in Reservoir Analogous Rocks: A Study on Laminated Limestones from the Crato Formation

    by Frederico Veiga Ribeiro Gonçalves, Daniel Milian Pérez, Abel Gámez Rodríguez, Yaicel Ge Proenza, Daniel Amancio Duarte, Márcio Fernando Paixão de Brito, Cássia Bezerra Machado, Raquel Milani, Daiane Francisca Do Nascimento Silva, Frederico Dias Nunes, et al.

    In recent decades, faster and more affordable methods for characterizing reservoir rocks in environmental and geological studies have gained importance, particularly for hydrocarbon exploration and resource management. One promising method is X-Ray Computed micro-Tomography (XR-?CT), enabling non-destructive analysis of rock properties. However, this technique presents challenges related to image interpretation, property characterization below the voxel scale, and result comparison across configurations. In this study, laminated limestones from the Crato Formation, analogs to the pre-salt Barra Velha Formation, were analyzed using XR-?CT to estimate density and porosity. These rocks serve as substitutes for actual reservoir conditions, addressing the challenge of limited subsurface samples. This study assessed the feasibility of XR-?CT for characterizing these properties and understanding the impact of millimeter-scale laminations on their distribution. Calibration values for calcite, the primary mineral, were used to ensure accuracy and repeatability. The results demonstrate that XR-?CT is a viable tool for environmental and geological characterization. Laminations due to stratification influenced porosity distribution in the axial direction, with higher concentrations in certain sections of the samples. The porosity values calculated using XR-?CT align relatively well with the gas porosimetry results, with most samples showing a relative difference of less than 10%. However, exceptions were observed in LM4 and T10.2, where the relative difference reached -15.90% and -12.80%, respectively. Despite these challenges, qualitative analysis was achieved. The study highlights the necessity of accounting for mineralogy and calibration in XR-?CT to ensure reliable comparisons across different tomographic systems, enhancing the method’s applicability in environmental and geological studies.