Vijay Maranholkar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vijay Maranholkar has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Binh V. Vu
Department of Chemical and Biomolecular Engineering, University of Houston, Houston, Texas 77204, USA
2 shared publications - Katerina Kourentzi
William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
2 shared publications - Richard C. Willson
Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX, USA
2 shared publications - Anjali Ramakrishna
R & D, Biocon Biologics Limited, Bommasandra-Jigani Link Road, Bangalore, India
1 shared publication - Anurag Singh Rathore
Indian Institute of Technology Delhi
1 shared publication - Atul Goyal
William A. Brookshire Department of Chemical and Biomolecular Engineering University of Houston Houston Texas USA
1 shared publication
Latest Publications
- Open Access
- 21 March 2025
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 4 (5) , 416-424
Lateral flow assay-based detection of nuclear fusion oncoprotein: implications for screening of acute promyelocytic leukemia
A lateral flow assay integrated with leukocyte isolation and on-filter cell lysis for the detection of PML–RARα nuclear fusion oncoprotein at point-of-care.
- 21 March 2025
- Published by Royal Society of Chemistry (RSC) in Sensors & Diagnostics
- Vol. 4 (5) , 416-424
Open AccessLateral flow assay-based detection of nuclear fusion oncoprotein: implications for screening of acute promyelocytic leukemia
A lateral flow assay integrated with leukocyte isolation and on-filter cell lysis for the detection of PML–RARα nuclear fusion oncoprotein at point-of-care.
- 10 December 2024
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 122 (3) , 538-547
Fluorescent Reporter‐Based Fiber Optic Probe for Continuous Detection of Antibodies
Measurement of antibody and antibody fusion protein concentration is vital for process development and manufacturing. Continuous, in‐line monitoring of antibody concentration could be useful in a variety of applications, such as controlling the loading of protein A columns to prevent breakthrough, monitoring bioreactor titer, and detecting leaks past ultrafiltration/diafiltration membranes. Molecule‐specific monitoring techniques are advantageous for antibody detection in cell culture fluid in the presence of complex process impurities. Here we report a continuous in‐line, real‐time IgG monitoring platform using a fiber‐optic biosensor with a replaceable sensor tip covalently functionalized with a fluor‐labeled protein consisting of a pentamer of the Z domain (a more stable form of the B domain) of protein A. The sensor demonstrates concentration‐dependent fluorescence enhancement in the presence of human IgG (0.01–0.75 g/L), with consistent signals during five runs each with 1 and 0.1 g/L IgG, and maintains its specificity in the presence of Chinese hamster ovary (CHO) cell culture fluid. A 5% breakthrough of a typical 10 g/L load would be detected in less than 20 s in a flowing stream emerging from a protein A column without prior sample preparation. This sensor platform may be suitable for monitoring IgG and fragment, crystallizable (Fc) fusion proteins in diverse upstream and downstream bioprocess applications.
- 10 December 2024
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 122 (3) , 538-547
Fluorescent Reporter‐Based Fiber Optic Probe for Continuous Detection of Antibodies
Measurement of antibody and antibody fusion protein concentration is vital for process development and manufacturing. Continuous, in‐line monitoring of antibody concentration could be useful in a variety of applications, such as controlling the loading of protein A columns to prevent breakthrough, monitoring bioreactor titer, and detecting leaks past ultrafiltration/diafiltration membranes. Molecule‐specific monitoring techniques are advantageous for antibody detection in cell culture fluid in the presence of complex process impurities. Here we report a continuous in‐line, real‐time IgG monitoring platform using a fiber‐optic biosensor with a replaceable sensor tip covalently functionalized with a fluor‐labeled protein consisting of a pentamer of the Z domain (a more stable form of the B domain) of protein A. The sensor demonstrates concentration‐dependent fluorescence enhancement in the presence of human IgG (0.01–0.75 g/L), with consistent signals during five runs each with 1 and 0.1 g/L IgG, and maintains its specificity in the presence of Chinese hamster ovary (CHO) cell culture fluid. A 5% breakthrough of a typical 10 g/L load would be detected in less than 20 s in a flowing stream emerging from a protein A column without prior sample preparation. This sensor platform may be suitable for monitoring IgG and fragment, crystallizable (Fc) fusion proteins in diverse upstream and downstream bioprocess applications.
- Open Access
- 1 June 2022
- Published by Elsevier in Journal of Chromatography Open
- Vol. 2, 100049
Optimization of multi flow rate loading strategy for process intensification of Protein A chromatography
- 1 June 2022
- Published by Elsevier in Journal of Chromatography Open
- Vol. 2, 100049
Open AccessOptimization of multi flow rate loading strategy for process intensification of Protein A chromatography