Matthieu Schoumacher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthieu Schoumacher has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Alix Mackowiak
Clinical Chemistry, Center for Interdisciplinary Research on Medicines (CIRM) University of Liège Liège Belgium
1 shared publication Ange Mouithys-Mickalad
1 shared publication- Bernard Pirotte
Center for Interdisciplinary Research on Medicines (CIRM) - Laboratory of Medicinal Chemistry, University of Liège, Avenue Hippocrate 15 (B36), B-4000, Liège, Belgium
1 shared publication C.LE Goff
Department of Clinical Chemistry, University Hospital of Liège, Belgium
1 shared publicationCaroline Le Goff
Clinical Chemistry, CIRM, University of Liège, Quartier Hopital, Avenue Hippocrate, 15, Liège 4000, Belgium; Department of Clinical Chemistry, CHU de Liège, Liège, Quartier Hopital, Avenue Hippocrate, 15, Liège 4000, Belgium
1 shared publicationE. Cavalier
Department of Clinical Chemistry, University Hospital of Liège, Belgium
1 shared publication
Latest Publications
- 3 January 2026
- Published by Elsevier in Animal Reproduction Science
- Vol. 286, 108098
Equine fetal-sex determination from mid-gestation to term using serum conjugated steroid profiling by liquid chromatography-tandem mass spectrometry
- 3 January 2026
- Published by Elsevier in Animal Reproduction Science
- Vol. 286, 108098
Equine fetal-sex determination from mid-gestation to term using serum conjugated steroid profiling by liquid chromatography-tandem mass spectrometry
- Open Access
- 1 April 2025
- Published by Stanford University Press in Journal of Mass Spectrometry and Advances in the Clinical Lab
- Vol. 36, 19-28
Development and validation of a highly-sensitive, quantitative LC-MS/MS assay to evaluate plasma oxytocin
Oxytocin is a 9-amino acid peptide that serves as neuromodulator in the human central nervous system. This peptide is implicated in the regulation of diverse behaviors and plays a significant role in positive social interaction. Currently, oxytocin levels are measured using immunoassays. However, these methods have several limitations that can lead to false results and erroneous interpretation. Given the remarkably low endogenous level of oxytocin in human plasma (low ng/L levels), we developed and rigorously validated a novel and highly sensitive LC-MS/MS method for oxytocin quantification in plasma. Oxytocin was initially extracted using solid-phase extraction with an Oasis HLB 30 mg plate and then subjected to LC-MS/MS analysis. PBS-0.1 % BSA served as surrogate matrix for the preparation of validation samples and the calibration curve, ensuring no endogenous interference. The validation design followed the Clinical Laboratory Standards Institute guidelines. Precision, accuracy, and measurement uncertainty were determined using single-nested analysis of variance and e.noval software. A lower limit of quantification of 1 ng/L was achieved. The method was validated for oxytocin concentrations ranging from 1 ng/L to 75 ng/L, with precision (coefficient of variation) below 10 %, accuracy ranging from 94 % to 108 %, and measurement uncertainty below 15 %. In this work, we developed and validated a highly sensitive LC-MS/MS method for the quantification of oxytocin in plasma. Our novel methodology is well-suited for clinical applications.
- 1 April 2025
- Published by Stanford University Press in Journal of Mass Spectrometry and Advances in the Clinical Lab
- Vol. 36, 19-28
Open AccessDevelopment and validation of a highly-sensitive, quantitative LC-MS/MS assay to evaluate plasma oxytocin
Oxytocin is a 9-amino acid peptide that serves as neuromodulator in the human central nervous system. This peptide is implicated in the regulation of diverse behaviors and plays a significant role in positive social interaction. Currently, oxytocin levels are measured using immunoassays. However, these methods have several limitations that can lead to false results and erroneous interpretation. Given the remarkably low endogenous level of oxytocin in human plasma (low ng/L levels), we developed and rigorously validated a novel and highly sensitive LC-MS/MS method for oxytocin quantification in plasma. Oxytocin was initially extracted using solid-phase extraction with an Oasis HLB 30 mg plate and then subjected to LC-MS/MS analysis. PBS-0.1 % BSA served as surrogate matrix for the preparation of validation samples and the calibration curve, ensuring no endogenous interference. The validation design followed the Clinical Laboratory Standards Institute guidelines. Precision, accuracy, and measurement uncertainty were determined using single-nested analysis of variance and e.noval software. A lower limit of quantification of 1 ng/L was achieved. The method was validated for oxytocin concentrations ranging from 1 ng/L to 75 ng/L, with precision (coefficient of variation) below 10 %, accuracy ranging from 94 % to 108 %, and measurement uncertainty below 15 %. In this work, we developed and validated a highly sensitive LC-MS/MS method for the quantification of oxytocin in plasma. Our novel methodology is well-suited for clinical applications.
- Open Access
- 19 December 2024
- Published by Elsevier in European Journal of Medicinal Chemistry Reports
- Vol. 13
Preparation and pharmacological characterization of the enantiomers of the anticancer agent R/S-N-3-cyanophenyl-N'-(6-tert-butoxycarbonylamino-3,4-dihydro-2,2-dimethyl-2H-1-benzopyran-4-yl)urea: Identification of the R-enantiomer as the active eutomer
- 19 December 2024
- Published by Elsevier in European Journal of Medicinal Chemistry Reports
- Vol. 13
Open AccessPreparation and pharmacological characterization of the enantiomers of the anticancer agent R/S-N-3-cyanophenyl-N'-(6-tert-butoxycarbonylamino-3,4-dihydro-2,2-dimethyl-2H-1-benzopyran-4-yl)urea: Identification of the R-enantiomer as the active eutomer